Empowering Scientific Discovery

Waters Technologies (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
ModelAtmospheric Pressure Gas Chromatography (APGC) Ion Source
Instrument TypeAtmospheric Pressure Chemical Ionization (APCI)-style GC-compatible ion source for triple quadrupole, Q-TOF, and ion mobility–enabled mass spectrometers
CompatibilityXevo TQ-S, Xevo G2-S QTof, SYNAPT G2-Si
Vacuum RequirementNone (operates at atmospheric pressure)
Switching Time<2 minutes between UPLC and GC modes
Design PrincipleEngineered Simplicity™
Regulatory AlignmentSupports 21 CFR Part 11-compliant workflows via MassLynx™ and UNIFI™ software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
ModelSELECT SERIES MRT
Mass Analyzer TypeMulti-Reflecting Time-of-Flight (MRT-TOF)
Instrument ClassHigh-Resolution Accurate-Mass (HRAM) LC-MS/MS System
Application ScopeUniversal (Life Sciences, Clinical Research, Forensics, Materials Surface Analysis)
Pressure RangeNot Applicable (Vacuum-operated analyzer)
Ion Sources SupportedDESI XS, SELECT SERIES MALDI, Electrospray (ESI), APCI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
ModelRADIAN ASAP
Ionization PrincipleAtmospheric Pressure Solid Analysis Probe (ASAP)
Mass AnalyzerSingle Quadrupole
Detection ModeFull Scan / Selected Ion Monitoring (SIM)
Sample IntroductionDirect Solid & Liquid Analysis
Software PlatformLiveID, IonLynx, OpenLynx
Compliance SupportFDA 21 CFR Part 11 (audit trail, electronic signature), GLP/GMP-ready workflows
DimensionsCompact benchtop footprint (< 60 cm width)
Typical Analysis Time< 30 seconds per sample
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
Instrument TypeQuadrupole-Time-of-Flight (Q-TOF)
ModelXevo G3 QTof
Application ScopeUniversal LC-MS/MS Platform
Mass RangeNot specified in source data
ResolutionNot specified in source data
Mass AccuracyNot specified in source data
SensitivityNot specified in source data
Pressure RangeNot specified in source data
Compliance ContextDesigned for GLP/GMP-aligned laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
Instrument TypeTandem Quadrupole (Triple Quad)
ModelXevo TQ-S cronos
ConfigurationLC-MS/MS System
Detection PrincipleElectrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) coupled with tandem mass spectrometry in Multiple Reaction Monitoring (MRM) mode
MRM Transition RateUp to 555 transitions per second
Linear Dynamic Range>5 orders of magnitude
Typical Precision<4% RSD for challenging analytes with 5 ms dwell time
Regulatory Compliance Support21 CFR Part 11, GLP/GMP audit trails, ISO/IEC 17025-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
Instrument TypeTandem Quadrupole (QqQ)
ModelXevo TQ-S micro
Ion Sources CompatibilityESI, APCI, ESCi, UniSpray, APGC, ionKey/MS, ASAP, Nanoflow ESI
LC CompatibilityACQUITY UPLC H-Class PLUS/Bio PLUS, I-Class PLUS, UPC2, M-Class
Key TechnologyZ-Spray Ion Source, StepWave Off-Axis Ion Focusing
Regulatory AlignmentCompliant with SANTE/11813/2017, FDA 21 CFR Part 11 (via MassLynx software), GLP/GMP data integrity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelXevo CDMS
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelACQUITY RDa Detector
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
ModelXevo TQ-XS
Instrument TypeTandem Quadrupole (Triple Quad)
Ionization Source CompatibilityUniSpray™, Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI)
Detection PrincipleSelected Reaction Monitoring (SRM) / Multiple Reaction Monitoring (MRM)
Dynamic Range6 orders of magnitude (Xtended Dynamic Range, XDR™)
Ion Transmission TechnologyStepWave XS™ off-axis ion optics
Probe DesignTool-free atmospheric pressure ionization (API) source
Software PlatformMassLynx™ NX, TargetLynx XS™, Intellistart™, QUANPEDIA™
Regulatory Compliance Support21 CFR Part 11, GLP/GMP audit trails, electronic signatures
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelACQUITY QDa II Mass Detector
PriceUpon Request
Instrument TypeSingle Quadrupole Mass Spectrometer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSYNAPT XS
Instrument TypeIon Mobility Mass Spectrometer
Application ScopeUniversal
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBioAccord LC-MS System
QuotationUpon Request
Instrument TypeTime-of-Flight (TOF)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
ModelXevo TQ-GC
Instrument TypeTriple Quadrupole Mass Spectrometer
Chromatography TypeGas Chromatography (GC)
Ionization ModesElectron Ionization (EI) and Chemical Ionization (CI)
Software PlatformTargetLynx™, Quanpedia™, IntelliStart™
Compliance FrameworkDesigned for GLP/GMP environments
Detection PrincipleSelected Reaction Monitoring (SRM) / Multiple Reaction Monitoring (MRM) in triple quadrupole configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelXevo MRT
Instrument TypeTime-of-Flight (TOF)
Application ScopeGeneral-Purpose
Resolution100,000 FWHM at 100 Hz
Mass Accuracy<500 ppb
m/z RangeBroad, consistent across full scan range
Analyzer ArchitectureMulti-Reflecting Time-of-Flight (MRT) with 4-meter effective flight path and 8 reflections
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBioAccord LC-MS System with ACQUITY Premier
Instrument TypeTime-of-Flight (TOF)
Application ScopeGeneral-Purpose
Software PlatformUNIFI Scientific Information System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
ModelXevo TQ Absolute
Instrument TypeTriple Quadrupole (TQ)
Application ScopeUniversal LC-MS/MS Quantitation
Mass RangeNot specified by manufacturer in public datasheets
SensitivityUp to 15× higher for challenging negative-ion-mode analytes vs. prior-generation TQ systems
ResolutionUnit mass resolution standard for SRM/MRM transitions
Mass AccuracyNot specified (typical for QqQ: ±0.1–0.2 Da under routine conditions)
Operating Pressure RangeVacuum system maintained at <1×10⁻⁶ mbar in analyzer region
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Instrument TypeTandem Quadrupole (QqQ)
ModelXevo TQD
Ionization FlexibilityUniversal Source Architecture Supporting ESI, APCI, ESCi, and Optional Atmospheric Pressure Photoionization (APPI)
Chromatographic CompatibilityOptimized for UPLC and HPLC Coupling
Data Acquisition SpeedHigh-speed MRM acquisition supporting sub-3-second UPLC peaks
Software SuiteMassLynx v4.2 with IntelliStart, Quanpedia, QCMonitor, TargetLynx, TrendPlot, and RADAR™ Mode
Regulatory Compliance Support21 CFR Part 11–compliant audit trails, electronic signatures, and GLP/GMP-ready workflow tools
Hardware ArchitectureRobust RF-only quadrupole design with T-Wave collision cell for enhanced ion transmission and fragmentation efficiency
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSELECT SERIES Cyclic IMS
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
ModelSQD2
Instrument TypeSingle Quadrupole Mass Spectrometer
Chromatography CompatibilityUPLC, HPLC, UPC², SFC, Prep-LC, Prep-SFC, ASAP Direct Analysis
Ionization ModesESI, APCI, UniSpray, ZSpray
Mass Range0–3000 m/z
Software PlatformMassLynx, OpenLynx Open Access, AutoPurification Integration
Regulatory ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
ModelXevo TQ Absolute XR
Instrument TypeTandem Quadrupole (Triple Quadrupole)
Application ScopeUniversal LC-MS/MS Analysis
Mass RangeNot Specified by Manufacturer
SensitivityNot Specified by Manufacturer
ResolutionNot Specified by Manufacturer
Mass AccuracyNot Specified by Manufacturer
Operating Pressure RangeNot Specified by Manufacturer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Instrument TypeTandem Quadrupole (QqQ)
ModelXevo TQ-S
Ionization FlexibilityUniversal Source Architecture
Key TechnologyStepWave™ Ion Guide, T-Wave™ Collision Cell, RADAR™ Simultaneous Quant/Qual Mode
Software SuiteMassLynx™, TargetLynx™, QCMonitor™, IntelliStart™, Quanpedia™
Regulatory Support21 CFR Part 11 compliant workflows, GLP/GMP-ready audit trails, ISO/IEC 17025-aligned data integrity framework
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUnited Kingdom
ModelDESI XS
CompatibilitySELECT SERIES Cyclic IMS, SYNAPT XS, Xevo G2-XS QTof
Ionization PrincipleDesorption Electrospray Ionization (DESI)
Environmental SealingPartially Enclosed Housing
Integrated ImagingSide-View Camera for Spray-Sample Alignment
Motion ControlStepper-Motor Stage with S-Curve Acceleration Algorithm
AutomationAuto-shutoff for Solvent Gas & High Voltage
Software IntegrationHDI™ Software for High-Resolution Mass Spectrometry Imaging
Regulatory ContextDesigned for GLP/GMP-compliant imaging workflows
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0