X-Ray Instruments
Filter
Showing 61–90 of 261 results
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-ECO |
| Element Range | Mg–U |
| LOD (soil matrix, 600 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Repeatability (Cd, soil) | ≤0.3 mg/kg, RSD <15% |
| Sample Types | Solid, liquid, powder, viscous |
| Detector | High-performance Silicon Drift Detector (SDD) |
| Excitation | Monochromatic focused excitation via doubly curved crystal (DCC) |
| Method | Single-wavelength excitation + energy-dispersive detection |
| Software | Fast FP® quantitative engine with matrix-adaptive modeling |
| Optional Preconcentration | Heavy Metal Enrichment Tape (HMET®) for aqueous samples (LOD: 1–3 µg/L) |
| Weight | 7.5 kg |
| Dimensions | 370 × 290 × 190 mm |
| Operation | Ambient air, no vacuum/gas required |
| Sample Interface | Motorized sample rotation stage |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-FVS |
| Instrument Type | Micro-Zone ED-XRF |
| Elemental Range | Mg to U |
| Detection Limits (Large Spot Mode, Light Matrix) | S: 10 mg/kg, Fe: 2 mg/kg, Pb: 1.0 mg/kg, Cd: 0.3 mg/kg |
| Minimum Focal Spot | φ200 µm |
| Spot Size Options | Software-Selectable Apertures (φ200–φ5000 µm, Rectangular Beam Optional) |
| X-Y Stage Range | ±10 mm |
| Step Resolution | 10 µm |
| Camera Magnification | 10×–100× |
| Sample Chamber Dimensions | 280 × 230 × 70 mm (L×W×H) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-HE & PHECDA-HES |
| Detection Limit (soil matrix, 300 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Repeatability (Cd, soil) | RSD < 15% at 0.3 mg/kg |
| Elemental Range | Mg–U |
| Sample Types | Solid, liquid, powder, viscous |
| Detector | High-performance Silicon Drift Detector (SDD) |
| Excitation Principle | Monochromatic focused excitation via doubly curved crystal (DCC) |
| Software | Fast FP® 2.0 quantitative engine |
| Auto-sampler | 30+ positions (PHECDA-HES) |
| HMET® integration for aqueous samples (detection limit | 1–3 µg/L) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-PRO |
| Excitation Principle | Monochromatic Focused Excitation (using doubly curved crystal monochromator) |
| Detection Principle | Energy-Dispersive XRF (ED-XRF) |
| Elemental Range | Mg–U |
| LOD (soil matrix, 600 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Precision (RSD) | Cd <15% at 0.3 mg/kg (soil, 600 s) |
| Sample Types | Solids, powders, slurries, liquids (with HMET® membrane enrichment), filters (e.g., PM₂.₅), and viscous matrices |
| Detector | High-performance silicon drift detector (SDD) with optimized active area and energy resolution |
| Software | Fast FP® quantitative engine (fundamental parameters-based, matrix-adaptive, standard-free or minimal-standard calibration) |
| Optional Enhancement | Heavy Metal Enrichment Technology (HMET®) for aqueous samples (LOD: 1–3 µg/L) |
| Portability | 8.7 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | SAXSpace |
| Instrument Type | Small-Angle and Wide-Angle X-ray Scattering (SAXS/WAXS) System |
| q-Range | 0.03–49 nm⁻¹ |
| Real-Space Resolution Range | 0.13–200 nm |
| Maximum 2θ | 74° |
| X-ray Source | Sealed-tube (line or point focus) |
| Beam Size | 20 × 0.3 mm² (line), 0.3 × 0.3 mm² (point) |
| Operating Voltage | 40 kV |
| Operating Current | 50 mA |
| Minimum Sample Volume | 7 µL (liquid), few mg (solid) |
| Temperature Control Range | −150 to 300 °C (±0.1 °C stability) |
| Measurement Time | 1–60 min |
| Automation | Motorized optical alignment, in situ heating/cooling, liquid handling compatibility |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SAXSpoint 500 |
| Instrument Type | Small-Angle X-ray Scattering (SAXS) System |
| q-Range | 0.02 nm⁻¹ to 43 nm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | XRDynamic Autosampler |
| Instrument Type | X-ray Crystal Orientation Analyzer |
| Instrument Configuration | Floor-standing |
| Sample Capacity | Up to 105 positions |
| Compatible With | XRDynamic 500 XRD system |
| Integration | Native integration with XRDdrive software |
| Sample Holder Compatibility | Standard ISO/ASTM-compliant sample holders (powder, solid, fiber, foil, thin film, air-sensitive samples) |
| Measurement Modes | Reflective and transmission geometries |
| Automation Level | Fully automated sample loading, positioning, alignment, and beam path switching |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable software logging |
| Brand | Anyty |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop ED-XRF |
| Model | 3R-AX6800S |
| Element Range | Na (11) to U (92) |
| Detection Limit | 1 ppm (matrix-dependent) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | 129 ± 5 eV @ Mn Kα |
| Repeatability | ≤ 0.05% RSD (for major elements, n=10) |
| Detector | Electrically Cooled Silicon Drift Detector (SDD) |
| Vacuum System | Integrated scroll pump, ultimate pressure 6.7×10⁻² Pa, pumping speed 60 L/min @ 50 Hz |
| Sample Chamber | Open design, 600 × 550 × 600 mm (L×W×H), equipped with HD coaxial camera |
| Power Supply | AC 220 V ±5 V, 50/60 Hz |
| Dimensions | 800 × 650 × 1400 mm |
| Weight | 230 kg |
| Brand | Anyty |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Form Factor | Benchtop |
| Power Consumption | 600 W |
| Angular Accuracy | ±0.02° |
| Angular Resolution | 0.04° |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AL-Y3000 |
| Instrument Type | Powder X-ray Diffractometer |
| Angular Resolution | 0.001° (1/1000°) |
| Geometry | θ–θ configuration |
| X-ray Source | Sealed Metal-Ceramic Tube |
| Detector | Silicon Drift Detector (SDD) |
| Primary Optics | Interchangeable Focusing and Parallel-Beam Optics via 90° Monochromator Rotation |
| Software | Integrated Rietveld Refinement, ICDD/ICSD Database Integration, Stress & Texture Analysis Modules |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ALW-XYDZ 700 |
| Power Supply | AC 220 V, 50 Hz, 0.25 kW |
| X-ray Tube | Cu anode, fan-cooled, grounded anode |
| Max. Tube Voltage/Current | 30 kV / 5 mA (continuously adjustable |
| Detector Options | Proportional counter (DC 1000 V max) or scintillation detector (DC 1200 V max) |
| Time Constant Settings | Fast (1) / Slow (2) |
| Angular Range | 2θ = −10° to 110°, θ = −5° to 55° |
| Angular Resolution | 1 arcsecond (1″), equivalent to 0.000278° |
| Angular Reproducibility | ±15″ / ±30″ (double-diffraction mode, verified with NIST-traceable quartz reference crystal) |
| Optical Shutter | Manual main shutter |
| Display Interface | Real-time angle readout + X-ray intensity meter |
| Dimensions (L×W×H) | 1132 × 642 × 1460 mm |
| Weight | 300 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ALW-XYDZ 700A |
| Price | Upon Request |
| Input Power | AC 220 V, 50 Hz, 0.25 kW |
| X-ray Tube | Cu anode, fan-cooled, grounded anode |
| Max. Tube Voltage/Current | 30 kV / 5 mA (continuously adjustable |
| Detector Options | Geiger–Müller counter (DC ≤1000 V) or scintillation detector (DC ≤1200 V) |
| Time Constant Settings | Fast (1) / Slow (2) |
| Angular Range | 2θ = −10° to 110°, θ = −5° to 55° |
| Angular Resolution | 1 arcsecond (″) in DMS format |
| Angular Accuracy (Double-Diffraction Mode) | ±15″ or ±30″ (verified using NIST-traceable quartz reference crystal) |
| Shielding | Fully enclosed lead-lined cabinet with interlocked automatic main shutter |
| Display | Dual digital readout — angular position (DMS + decimal degree, with presettable target and deviation) and X-ray intensity |
| Dimensions (L×W×H) | 1132 × 642 × 1460 mm |
| Weight | 300 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | ALYX-500 |
| Price | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger–Müller counter |
| Angular Range | θ = −10° to +50°, 2θ = −10° to +100° |
| Angular Resolution | Digital readout with programmable positioning |
| Beam Shutter | Motorized |
| Dimensions | 700 × 530 × 1400 mm (L × W × H) |
| Weight | 100 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ALYX-800 |
| Price | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger-Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Optical Shutter | Manual |
| Dimensions | 910 mm (L) × 660 mm (W) × 1220 mm (H) |
| Weight | 150 kg |
| Brand | Aolong |
|---|---|
| Origin | Japan |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Upon Request |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | Sapphire Four-Axis |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Time Constants | 0.1 s / 0.4 s / 3 s |
| Slit Apertures | 4′ / 5′ / 6′ |
| Optical Shutter | Motorized |
| Control Unit Dimensions | 550 × 350 × 1700 mm (L×W×H) |
| Measurement Unit Dimensions | 750 × 550 × 1800 mm (L×W×H) |
| Weight | 180 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | YX-200 |
| Price | Upon Request |
| X-ray Tube | Cu anode, air-cooled, 30 kV / 0–5 mA |
| Detector | Geiger-Müller counter |
| Angular Range | θ = −10° to +50°, 2θ = −10° to +100° |
| Angular Resolution | 10 arcseconds (″) |
| Digital Display | Degrees, Minutes, Seconds |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| Dimensions | 1140 × 650 × 1030 mm (L×W×H) |
| Weight | 150 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | YX-300 |
| Price | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger–Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Angular Range | θ = −10° to +50°, 2θ = −10° to +100° |
| Angular Resolution | 1″ (digital display), minimum readable increment 1″ |
| Accuracy | ±10″ |
| Optical Shutter | Manual |
| Display | Digital angle readout |
| Dimensions | 1150 mm × 665 mm × 1040 mm (L×W×H) |
| Weight | 150 kg |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HELIUS Series |
| Pricing | Upon Request |
| [Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AT-X100 |
| Portability | Handheld / Field-Deployable |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99% (w/w) |
| Repeatability | ≤ 0.1% RSD |
| Detector Options | Si-Pin or SDD (Selectable) |
| Compliance | Designed for field-deployable environmental screening per EPA Method 6200, ASTM D7298, and China’s HJ 1003–2018] |
| Brand | Auniontech |
|---|---|
| Model | micro-CT |
| X-ray Tube Voltage | Up to 200 kV |
| Detector Resolution | Up to 16 MP |
| Scan Speed | < 10 s per scan |
| Number of Projections | Up to 8-axis acquisition |
| Spatial Resolution | 0.4 µm – 5 µm |
| System Weight | 20 kg (CT-PORTABLE variant) |
| Radiation Leakage | < 1 µSv/h |
| Power Output | Up to 65 W (CT-XPRESS variant) |
| Brand | Auniontech |
|---|---|
| Model | MICRO FOCUS X |
| Target Spot Size | 5–10 µm (power-dependent) |
| Operating Voltage | 20–100 kV |
| Max Power | 15 W |
| Focus-to-Window Distance (FOD) | 7 mm |
| Anode Material | Tungsten (W) / Copper (Cu) |
| Input Power | 24 VDC / 2 A |
| Weight | 4.5 kg |
| Dimensions | 524 × 490.25 × 206.5 mm |
| Window Thickness | 0.254 mm |
| Beam Divergence | 95° conical |
| Cooling | Integrated fan (sufficient for ambient ≤28°C) |
| Operating Temp | +10°C to +40°C |
| HV Ripple (full load) | ≤0.1% p-p |
| Voltage/Current Regulation | ±0.25% |
| Interface | RS-232C |
| OS Compatibility | Windows 7/8.1/10 |
| Window Type | Side-window and end-window configurations available |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-Made) |
| Model Designation | XRF-Desktop Series |
| Form Factor | Benchtop |
| Detector Technology | Silicon Drift Detector (SDD) |
| Elemental Range | Na (11) to U (92) |
| Simultaneous Elements | Up to 25 |
| Coating Layers | Up to 5 (including alloy substrates) |
| Analysis Mode | Fundamental Parameters (FP) & Standardless Quantitative Analysis |
| Software Platform | Archer™ XRF Suite |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible workflows |
| Connectivity | USB 2.0 |
| Footprint | < 400 × 350 × 300 mm |
| Weight | < 25 kg |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Detector Type | Silicon Pin Diode (SiPIN) and Fast Silicon Drift Detector (FASTSDD) with Boron Carbide (B4C) Window |
| Element Range | Na (11) to U (92) |
| Detection Limit | 1 ppm |
| Analytical Range | 1 ppm – 99.99% |
| Repeatability | ±0.1% RSD |
| Form Factor | Handheld/Portable Compatible |
| Compliance | RoHS-compliant, Be-free alternative per ASTM E1361 and ISO 18557 |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CTX |
| Application | Portable/Benchtop |
| Industry Type | General-Purpose |
| Elemental Range | Mg to U |
| Quantification Range | ppm to % |
| Energy Resolution | 145 eV |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D6 PHASER |
| Instrument Type | Powder X-ray Diffractometer |
| Generator Power | 600 W or 1200 W |
| 2θ Calibration Accuracy | ±0.01° |
| Detector | LYNXEYE XE-T Energy-Resolving Detector |
| Beam Optimization | Dynamic Beam Optimization (DBO) |
| Cooling | Air-Cooled (No External Water Chiller Required) |
| Footprint | Compact Benchtop Design |
| Measurement Geometries | Bragg–Brentano Reflection, Transmission, Grazing-Incidence XRD (GIXRD), X-ray Reflectivity (XRR), Residual Stress Analysis, Texture Analysis |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | D7 Mate |
| Price Range | USD 28,000 – 140,000 |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| Power Rating | 600 W / 1200 W (Selectable) |
| Angular Accuracy | ±0.0001° |
| High-Voltage Generator | 40 kV / 600 W or 40 kV / 1200 W |
| Target Materials | Cu, Cr, Mo |
| Goniometer Geometry | Horizontal θ/2θ or ω/θ |
| Goniometer Radius | 150 mm |
| Angular Range | −3° to 152° (140° with automatic beam-defining slit) |
| Repeatability | <0.0001° (2σ) |
| Detector | 640-channel 1D silicon strip detector, active area 32 mm × 8 mm |
| Cooling | Integrated recirculating water chiller (standard), optional external chiller interface |
| Beam Path | Air-scatter suppression module with motorized divergence slit and automatic anti-scatter device |
| Sample Stages | Fixed stage, in-situ heating stage, multi-axis rotating stage, capillary stage, thin-film stage, multifunctional stage, pouch-cell battery stage, high-throughput 8-position rotary stage, optional 6-position automated sample loader |
| Data Reproducibility | NIST SRM 660c LaB₆ reference standard, RSD ≤ 0.003% (peak position, 2θ) |
| Control Interface | External PC or integrated 10.1″ capacitive touchscreen |
| Dimensions (L×W×H) | 880 mm × 705 mm × 735 mm |
| Mass | ≤180 kg |
| Electrical Supply | AC 200–240 V, 50/60 Hz |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D8 ADVANCE |
| Instrument Type | Powder X-ray Diffractometer |
| Power | 0.0001° angular resolution |
| 2θ Range | −110° to +168° |
| X-ray Tube Targets | Cr / Co / Cu (standard-size) |
| Detector Options | LYNXEYE Array Detector, LYNXEYE XE-T Energy-Dispersive Detector |
| Dimensions | 1868 × 1300 × 1135 mm |
| Weight | 770 kg |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D8 DISCOVER |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 0.0001 kW |
| Compliance | Fully Compliant with ISO 17025, ASTM E975, and IEC 61000-6-3 for Electromagnetic Compatibility |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Powder X-ray Diffractometer |
| Model | D8 ENDEAVOR |
| Detector | LYNXEYE XE-T Energy-Resolving Array Detector |
| Sample Handling | 66-position or 72-position automated sample changer (Ø 51.5 mm and Ø 40 mm formats) |
| Automation Modes | Belt-driven or robotic integration |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Regulatory Context | Fully compatible with FDA 21 CFR Part 11–compliant data management workflows |