| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Model | IFFM-EA |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 325–1000 nm |
| Cuvette Path Length | 10 mm (standard, fixed) |
| Wavelength Accuracy | ≤ ±2 nm |
| Wavelength Repeatability | 1 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | < 0.1% T (at NaNO₂) |
| Dark Current Drift | 0.2% T / 3 min |
| Light Current Drift | 0.5% T / 3 min |
| Data Acquisition Rate | 1–100 samples/s |
| Gain Settings | 1×, 2×, 4×, 8×, 16× |
| Filter Cutoff Frequency | 10–100 Hz |
| Pump Speed Control | 0–99 digital steps |
| Number of Pump Channels | 10 (5 per pump) |
| Valve Configuration | 16-position auto/manual selector valve |
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RPSE-A |
| Pricing | Upon Request |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | ≥10 MΩ |
| Current Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Wavelength Range (Monochromator) | 300–800 nm (standard), optional 200–800 nm |
| Spectral Resolution | 4.32 nm (adjustable via slit pairs: 0.4–7.2 nm, slit widths 0.05–1.0 mm) |
| Wavelength Accuracy | ±0.2% |
| Wavelength Repeatability | ±0.15% |
| Monochromator Scan Speed | 50 nm/s (standard), 100 nm/s (high-speed) |
| Exit Slit Width | 600 µm |
| Scan Modes | Time-based, fixed-point, range-scan, cyclic scan |
| Photodetector Wavelength Range | 230–700 nm |
| Peak Sensitivity Wavelength | 420 nm |
| Detection Method | Single-Photon Counting |
| Integration Times | 1 ms to 3600 s (12 selectable steps) |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MPI-EII |
| Pricing | Available Upon Request |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | 10 MΩ |
| Current Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Luminescence Dynamic Range | >5 decades |
| Photometric Accuracy | <0.05% |
| Gain Settings | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Amplifier Drift | <0.05% |
| Peak-to-Peak Noise | ≤0.5 mV (1× gain) |
| Input Impedance (Optical) | ≥10 MΩ |
| Integration Time | 0.01–10 s |
| Sampling Rate | 1–200 Hz |
| PMT High Voltage | −100 V to −1000 V |
| Spectral Range | 230–920 nm (λₚₑₐₖ = 630 nm) |
| Anode Sensitivity | >2000 A/lm |
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-F |
| Type | Flow Injection Chemiluminescence (FICL) Analyzer |
| Detection Principle | Photomultiplier Tube (PMT)-based chemiluminescence detection with integrated flow injection manifold and electrochemical compatibility |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Software Interface | Windows-native USB communication protocol (USB 2.0 compliant), real-time data streaming to host PC |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | RFFS-1 |
| Price | Upon Request |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RPEC-A |
| Light Source | 300 W Xenon Arc Lamp |
| Spectral Range | 200–1000 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | ±0.1 nm |
| Minimum Wavelength Step | 0.01 nm |
| Spectral Bandwidth | 0.054–16.2 nm (adjustable slit: 10 µm–3 mm) |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Scan Rate | 0.001–65 V/s |
| Reference Electrode Input Impedance | 10 MΩ |
| Operating System | Windows-based Dedicated Software |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RFL-II |
| Detector Type | Electrochemical Luminescence Analyzer with Integrated Spectral Photomultiplier Module |
| High-Voltage Power Supply | −100 V to −1000 V (stability ±0.05%, output current ≥5 mA) |
| Gain Settings | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Signal Noise | ≤0.5 mV<sub>P-P</sub> (at 1× gain) |
| Input Impedance | ≥10 MΩ |
| Integration Time Range | 0.01–1000 s |
| Sampling Rate | 1–1000 Hz |
| Spectral Response | 230–920 nm (peak sensitivity at 630 nm) |
| Anode Sensitivity | >2000 A/lm |
| Software Functions | Real-time signal acquisition, auto-zero calibration, AGC (Automatic Gain Control), peak/area quantification, spectral export (TXT), VFD-based local parameter display |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-A |
| Current Range | ±250 mA |
| Potential Range | −10 V to +10 V |
| Reference Electrode Input Impedance | 10 MΩ |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| CE High-Voltage Power Supply Output | 0–20 kV / 0–300 µA |
| Photodetector HV Input | −100 to −1000 V |
| Wavelength Response Range | 300–650 nm (peak @ 420 nm) |
| Dynamic Range | >5 decades |
| Amplifier Gain | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Integration Time | 0.001–10 s |
| Sampling Rate | 1–200 Hz |
| Signal Noise | ≤0.5 mV (P-P, 1× gain) |
| Amplifier Drift | <0.05% |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-E |
| Current Range | ±250 mA |
| Potential Range | −10 V to +10 V |
| Reference Electrode Input Impedance | 10 MΩ |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 auto-ranging decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Luminescence Detection Dynamic Range | >5 decades |
| Photomultiplier Tube (PMT) High Voltage | −100 V to −1000 V |
| Emission Wavelength Range | 300–650 nm (Peak Sensitivity at 420 nm) |
| PMT Spectral Responsivity | >1000 A/lm |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | IFIS Series |
| Product Type | Flow Injection Sampler |
| Pump Speed Range | 0–99 rpm |
| Maximum Sample Throughput | >600 samples/h |
| Number of Integrated Peristaltic Pumps | Dual |
| Number of Fluid Channels | Up to 10 (5 per pump) |
| Valve Configuration | Dual 16-position auto/manual switching valves (supporting up to 8 independent fluid paths) |
| Programmable Steps | Up to 15 sequences × 10 steps each |
| Control Interface | RS-232/USB |
| Brand | REMEX (Xi’an Remex) |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RPEL-B |
| Pricing | Upon Request |
| Potential Applications | Antigen/Antibody Detection, Pathogen Screening (e.g., Influenza A, HIV, Plague), Small-Molecule Biomarker Analysis (Hormones, Toxins, Glucose, Amino Acids) |
| Operating Modes | Standalone & PC-Connected (USB) |
| Electrode Format | Disposable Screen-Printed Electrodes (WE: Pt, CE: Pt, RE: Ag/AgCl or user-specified) |
| Dimensions | 140 × 110 × 110 mm (L×W×H) |
| Weight | <0.8 kg |
| Battery Life | >10 h continuous operation |
| Data Storage | Up to 1000 assay records |
| Optical Detection Range | 230–920 nm |
| Electrochemical Range | Potential: −3 V to +3 V |
| Current | ±50 mA |
| Scan Rate | 0.001–200 V/s |
| Sampling Rate | 1–200 points/s |
| Dynamic Range | >5 decades |
| Measurement Accuracy | <0.05% FS |
| Interfaces | USB 2.0 (PC control/data transfer), DB9 RS-232 (mini-printer output) |
| Integrated Magnetic Separation Module | Yes |
| Sample Volume | 5–10 µL per test |
| Compatible Substrates | Paper-based chips, ceramic chips, custom solid-phase electrochemiluminescent platforms |