Empowering Scientific Discovery

Xi'an Ruimai Analytical Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandREMEX
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelMPI-EII
PricingAvailable Upon Request
Electrochemical Potential Range−10 V to +10 V
Current Range±250 mA
Reference Electrode Input Impedance10 MΩ
Current Sensitivity1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades)
Input Bias Current<50 pA
Potential Increment1 mV
Scan Rate0.001–65 V/s
Luminescence Dynamic Range>5 decades
Photometric Accuracy<0.05%
Gain Settings1×, 10×, 100×, 1000×
Filter Frequencies10 Hz, 20 Hz, 50 Hz, 100 Hz
Amplifier Drift<0.05%
Peak-to-Peak Noise≤0.5 mV (1× gain)
Input Impedance (Optical)≥10 MΩ
Integration Time0.01–10 s
Sampling Rate1–200 Hz
PMT High Voltage−100 V to −1000 V
Spectral Range230–920 nm (λₚₑₐₖ = 630 nm)
Anode Sensitivity>2000 A/lm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandREMEX (Xi’an Remex Instrument Co., Ltd.)
OriginShaanxi, China
ModelRPEC-A
Light Source300 W Xenon Arc Lamp
Spectral Range200–1000 nm
Wavelength Accuracy±0.25 nm
Wavelength Repeatability±0.1 nm
Minimum Wavelength Step0.01 nm
Spectral Bandwidth0.054–16.2 nm (adjustable slit: 10 µm–3 mm)
Electrochemical Potential Range−10 V to +10 V
Current Range±250 mA
Sensitivity1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades)
Input Bias Current<50 pA
Scan Rate0.001–65 V/s
Reference Electrode Input Impedance10 MΩ
Operating SystemWindows-based Dedicated Software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandREMEX (Xi’an Remex Instrument Co., Ltd.)
OriginShaanxi, China
ModelRFL-II
Detector TypeElectrochemical Luminescence Analyzer with Integrated Spectral Photomultiplier Module
High-Voltage Power Supply−100 V to −1000 V (stability ±0.05%, output current ≥5 mA)
Gain Settings1×, 10×, 100×, 1000×
Filter Frequencies10 Hz, 20 Hz, 50 Hz, 100 Hz
Signal Noise≤0.5 mV<sub>P-P</sub> (at 1× gain)
Input Impedance≥10 MΩ
Integration Time Range0.01–1000 s
Sampling Rate1–1000 Hz
Spectral Response230–920 nm (peak sensitivity at 630 nm)
Anode Sensitivity>2000 A/lm
Software FunctionsReal-time signal acquisition, auto-zero calibration, AGC (Automatic Gain Control), peak/area quantification, spectral export (TXT), VFD-based local parameter display
Added to wishlistRemoved from wishlist 0
Add to compare
BrandREMEX
OriginShaanxi, China
ModelMPI-A
Current Range±250 mA
Potential Range−10 V to +10 V
Reference Electrode Input Impedance10 MΩ
Sensitivity1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades)
Input Bias Current<50 pA
Potential Increment1 mV
Scan Rate0.001–65 V/s
CE High-Voltage Power Supply Output0–20 kV / 0–300 µA
Photodetector HV Input−100 to −1000 V
Wavelength Response Range300–650 nm (peak @ 420 nm)
Dynamic Range>5 decades
Amplifier Gain1×, 10×, 100×, 1000×
Filter Frequencies10 Hz, 20 Hz, 50 Hz, 100 Hz
Integration Time0.001–10 s
Sampling Rate1–200 Hz
Signal Noise≤0.5 mV (P-P, 1× gain)
Amplifier Drift<0.05%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandREMEX (Xi’an Remex Instrument Co., Ltd.)
OriginShaanxi, China
ModelMPI-E
Current Range±250 mA
Potential Range−10 V to +10 V
Reference Electrode Input Impedance10 MΩ
Sensitivity1 × 10⁻⁹ A to 1 × 10⁻² A (8 auto-ranging decades)
Input Bias Current<50 pA
Potential Increment1 mV
Scan Rate0.001–65 V/s
Luminescence Detection Dynamic Range>5 decades
Photomultiplier Tube (PMT) High Voltage−100 V to −1000 V
Emission Wavelength Range300–650 nm (Peak Sensitivity at 420 nm)
PMT Spectral Responsivity>1000 A/lm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandREMEX (Xi’an Remex)
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelRPEL-B
PricingUpon Request
Potential ApplicationsAntigen/Antibody Detection, Pathogen Screening (e.g., Influenza A, HIV, Plague), Small-Molecule Biomarker Analysis (Hormones, Toxins, Glucose, Amino Acids)
Operating ModesStandalone & PC-Connected (USB)
Electrode FormatDisposable Screen-Printed Electrodes (WE: Pt, CE: Pt, RE: Ag/AgCl or user-specified)
Dimensions140 × 110 × 110 mm (L×W×H)
Weight<0.8 kg
Battery Life>10 h continuous operation
Data StorageUp to 1000 assay records
Optical Detection Range230–920 nm
Electrochemical RangePotential: −3 V to +3 V
Current±50 mA
Scan Rate0.001–200 V/s
Sampling Rate1–200 points/s
Dynamic Range>5 decades
Measurement Accuracy<0.05% FS
InterfacesUSB 2.0 (PC control/data transfer), DB9 RS-232 (mini-printer output)
Integrated Magnetic Separation ModuleYes
Sample Volume5–10 µL per test
Compatible SubstratesPaper-based chips, ceramic chips, custom solid-phase electrochemiluminescent platforms
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0