- All
- Favorite
- Popular
- Most rated
| Brand | BAQ |
|---|---|
| Origin | Germany |
| Model | KaloMAS II S |
| Ball Diameter | 15–40 mm |
| Planar Sample Clamp Range | 50 mm (customizable) |
| Cylindrical Sample Clamp Range | 3–30 mm (customizable) |
| Cross-Stage Travel | 25 × 25 mm |
| Display | 480 × 640 px color LCD |
| Rotational Speed | 50–1000 rpm |
| Grinding Time | Programmable |
| Dimensions (W×D×H) | 300 × 295 × 270 mm |
| Power Supply | 85–264 VAC, 47–63 Hz |
| Weight | ~8 kg |
| Measurable Coating Thickness | 0.3–50 µm |
| Ball Cap Diameter | 0.1–3 mm |
| Thickness Measurement Accuracy | 1–5% (surface roughness dependent) |
| Brand | BAQ |
|---|---|
| Origin | Germany |
| Model | kaloMAX II |
| Measuring Principle | Ball cratering (geometric depth determination via spherical indentation) |
| Thickness Range | 0.3 – 30 µm |
| Ball Diameter | 15 – 30 mm |
| Planar Sample Clamp Range | 50 mm |
| Circular Sample Clamp Range | 3 – 30 mm (customizable) |
| Cross-Stage Travel | 25 × 25 mm |
| Tilt Angle | 60° |
| Drive Shaft Speed | 100–1200 rpm (12 preset values) |
| Cycle Time | 5–180 s (20 preset values) |
| Display | 4-digit speed, 4-digit timer, 1-digit program ID |
| Input Voltage | 85–264 VAC |
| Input Frequency | 47–63 Hz |
| Dimensions (W×D×H) | 300 × 295 × 235 mm |
| Weight | ~8 kg |
| Accuracy | ±1–5% (surface roughness dependent) |
| Optional | Removable clamp base, graded abrasive slurries, high-resolution microscope camera system, kaloSOFT evaluation software, integrated automation-ready configuration |
| Brand | Applytest |
|---|---|
| Model | NMM-1020 |
| Measurement Principle | Eddy Current |
| Power Supply | Rechargeable Lithium Battery (20 h runtime) |
| Minimum Sample Size | 150 × 150 mm (flat) |
| Active Measurement Area | Ø40 mm |
| Measurement Mode | Contact or Non-Contact (non-contact requires optional probe holder) |
| Supported Substrates | Plastic, Glass, Polymer Films, Semiconductor Wafers |
| Bluetooth Data Transfer | Optional |
| Compliance | ISO/IEC 17025-compatible operation environment, supports GLP audit trails |
| Brand | Applied Spectroscopy |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | TranSpec Lite MC-UVNIR-H |
| Wavelength Range | 190–1020 nm |
| Measurement Range | 0.8–100 µm |
| Accuracy | ±0.005 µm |
| Repeatability | ±0.002 µm (per standard WEG test) |
| Brand | Applytest |
|---|---|
| Model | NMM-1020 |
| Measurement Principle | Eddy Current |
| Power Supply | Rechargeable Lithium Battery (20 h runtime) |
| Minimum Sample Size | 150 × 150 mm (flat) |
| Active Measurement Area | Ø40 mm |
| Surface Compatibility | Flat and Curved Substrates (custom calibration profiles supported) |
| Measurement Modes | Contact and Non-Contact (non-contact requires optional probe holder) |
| Connectivity | Bluetooth (optional) |
| Display | Integrated Touchscreen Interface |
| Compliance | Designed for ISO 2360, ASTM B244, and IEC 61000-4-3 compliant operation |
| Software | On-device measurement management with export to CSV/Excel |
| Key Measurables | Al (5–540 nm), In (24–2700 nm), Cr (24–2600 nm), Ti (102–11080 nm), Cu (3–340 nm), Ag (3–310 nm), Sn (21–2300 nm), Ni (12–1280 nm) |
| Brand | AIM Systems (Germany) |
|---|---|
| Origin | Germany |
| Model | CoatPro |
| Measurement Principle | Optical Interferometry & Spectral Reflectance Analysis |
| Measurement Type | Simultaneous Wet-Film and Dry-Film Thickness |
| Substrate Compatibility | Metallic, Polymeric, Glass, Rubber, Composite |
| Surface Geometry Support | Curved, Rough, Internal Walls, Complex Geometries |
| Environmental Rating | ATEX Zone 1 & Zone 2 Certified |
| Cooling Requirement | Passive Air-Cooled (No Water Cooling Required) |
| Data Output | Real-Time Streaming via EtherNet/IP, PROFINET, Modbus TCP |
| Reporting | Automated PDF/CSV Report Generation with Statistical Process Control (SPC) Metrics |
| Compliance | ISO 2808, ASTM D7091, EN ISO 19840, IEC 60079-0/-11, FDA 21 CFR Part 11 (Audit Trail Enabled) |
Show next