- All
- Favorite
- Popular
- Most rated
| Brand | Autobio |
|---|---|
| Model | AutoMimo1200 |
| Origin | Henan, China |
| Instrument Type | Benchtop Automated Sample Dispensing System |
| Throughput | Up to 800 assay positions per hour |
| Compliant with ISO 13485 | 2016 Quality Management System |
| Brand | Autobio |
|---|---|
| Model | Autof ms2000 |
| Origin | Henan, China |
| Laser Source | Solid-state, ≥10⁹ shots lifetime, 1–1000 Hz tunable frequency |
| Ion Source Vacuum | ≤10⁻⁷ mbar |
| Ion Source Maintenance | Auto-cleaning cycle ≤10 min |
| Mass Analyzer | Titanium alloy flight tube with high thermal stability |
| Vacuum System | High-throughput turbomolecular pump |
| Signal Acquisition | High-precision FPGA-controlled real-time digitizer |
| Software Platform | AI-accelerated microbial identification engine (96 samples in <5 min) |
| Database Coverage | >1,000 genera, >5,000 species, >16,000 strains |
| Regulatory Status | CE-IVD compliant |
| Data Security | On-premise and cloud-deployable database options |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Automs TQ6000 |
| Price Range | USD 300,000–320,000 (FOB) |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Scope | General-Purpose LC-MS/MS |
| Maximum System Pressure | >12,000 psi |
| Ionization Modes | Dual ESI/APCI with Tool-Free Switching |
| Software Interface | Fully Localized Chinese GUI with Intelligent Quantitation & Method Development Engine |
| Regulatory Compliance | Designed to support GLP/GMP workflows, audit trail-enabled data handling, and 21 CFR Part 11–compliant user access control (optional configuration) |
| Brand | Autobio |
|---|---|
| Model | LUMO |
| Detection Method | Chemiluminescence |
| Detector Type | Imported Photomultiplier Tube (PMT) |
| Luminescence Range | 10⁰–10⁹ RLU |
| Plate Format | 96-well and 48-well microplates |
| Read Time per Well | 0.1–10 s |
| Full 96-Well Plate Read Time | <32 s |
| Sensitivity | 10⁻² mol/plate |
| Precision (CV) | <2% |
| Inter-well Cross-Talk | <5×10⁻⁷ |
| Plate Shaking Modes | 3 programmable patterns (speed & duration adjustable) |
| Power Input | 220 V ± 22 V AC |
| Power Consumption | <32.4 VA |
| Dimensions (L×W×H) | 470 × 335 × 205 mm |
| Weight | 13 kg |
| Safety Compliance | CE-marked, 24 V DC internal supply, ISO 13485 certified |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AutoMic i600 |
| Pricing | Available Upon Request |
| Brand | Autobio |
|---|---|
| Model | PHOMO |
| Origin | Henan, China |
| Instrument Type | Multifunctional Automated Microplate Reader |
| Assay Mode | Endpoint |
| Calibration Curve | Linear |
| Detector | Dual-LED Laser-Based Photodiode Array |
| Wavelength Range | 200–1000 nm |
| Absorbance Range | 0–4.5 OD |
| Absorbance Linearity | 0.000–2.000 Abs ±0.01% |
| Measurement Speed | 12 s (single wavelength), 20 s (dual wavelength), 6 s (kinetic single-wavelength) |
| Precision (CV) | <0.5% |
| Repeatability (CV) | ≤0.15% |
| Light Source | Dual-LED Cold Light Source (Lifetime ≥100,000 h) |
| Optical Architecture | RSE (Real-time Spectral Enhancement) Silicon Photodetector Platform |
| Scan Mode | Multi-point per well (up to 9 points) |
| Brand | Autobio |
|---|---|
| Model | Sikun2000 |
| Instrument Type | Second-Generation Sequencing Platform |
| Regulatory Status | CE-IVDR and NMPA-Certified In Vitro Diagnostic Device |
| Form Factor | Benchtop Sequencer |
| Read Length Range | 50–300 bp |
| Data Quality | Q30 ≥ 85%–90% |
| Accuracy | >99.9% Base Call Accuracy (per-cycle consensus) |
| Run Time | As fast as 3.2 hours (dependent on read length and chip configuration) |
| Throughput | Mid-Throughput Chip: 220 million reads (11–66 Gb) |
| High-Throughput Chip | 660 million reads (33–200 Gb) |
| Chemistry | Surface-Based Bridge Amplification with Reversible Dye-Terminator Fluorescence Detection |
| Compliance | Designed and validated per ISO 13485, IEC 62304, and aligned with FDA 21 CFR Part 820 and EU IVDR Annex I essential requirements |
| Brand | Autobio |
|---|---|
| Model | Sikun1000 |
| Instrument Type | Second-Generation Sequencing Platform |
| Regulatory Status | CE-IVD & NMPA-Certified In Vitro Diagnostic Device |
| Form Factor | Benchtop Sequencer |
| Read Length | 50–300 bp |
| Throughput | 110M–330M Reads per Run |
| Data Output | 5–100 Gb per Run |
| Run Time | 3.5–24 h |
| Base Call Accuracy (Q30) | >85%–90% |
| Optical Detection Method | Fluorescence-Based Sequencing-by-Synthesis on Solid-Phase Amplified Flow Cell |
| Compliance | ISO 13485, IEC 62304, FDA 21 CFR Part 820, GLP/GMP-Aligned Data Integrity Framework |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Autof ms1600 |
| Price Range | USD 420,000 – 560,000 |
| Instrument Type | MALDI-TOF Mass Spectrometer |
| Application Scope | Universal |
| Resolution | ≥3600 (Linear Mode) |
| Sensitivity | 50 fmol/µL (Insulin, S/N ≥ 60) |
| Mass Accuracy | <60 ppm (Internal Calibration) |
| Data Acquisition Rate | 0.5 GBit/sec |
| Stability | High Long-Term Operational Stability |
| Brand | Autobio |
|---|---|
| Model | Sikun500 |
| Instrument Type | Second-Generation Sequencing Platform |
| Medical Device Classification | Class III (China NMPA) |
| Form Factor | Benchtop Sequencer |
| Read Length | 50–300 bp |
| Q30 Score | >85–90% |
| Sequencing Accuracy | >99.9% |
| Run Time | 3.5–24 hours |
| Throughput | 60M–170M Reads per Run |
| Data Output | 5–50 Gb per Run |
| Origin | Henan, China |
| Regulatory Status | CE-IVD compliant (pending), NMPA registered |
| Brand | Autobio |
|---|---|
| Model | Autof MS |
| Origin | Henan, China |
| Laser Lifetime | >100 million shots |
| Mass Analyzer | Titanium Alloy Linear TOF (1.05 m) |
| Vacuum System | High-Throughput Turbo-Molecular Pump |
| Identification Speed | ≤0.1 s per sample (database search) |
| Microbial Database | 5,000+ species across 1,000+ genera, including filamentous fungi, anaerobic gut bacteria, and marine isolates |
| Nucleic Acid Detection Capacity | Up to 40-plex per well |
| Regulatory Certification | NMPA-approved calibration and control materials |
| Software Compliance | Audit trail, user access control, and electronic signature support per FDA 21 CFR Part 11 requirements |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | iWO-960 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configuration | 12-channel |
| Rinse Head Design | Integrated Anti-Clogging Mesh Filter |
| Fluid Channels | One wash solution channel + one waste aspiration channel |
| Soak Time Range | 0–10 seconds (adjustable in 1-s increments) |
| Wash Cycles | Manual or programmable auto-mode (1–10 cycles) |
| Residual Volume per Well | ≤1 µL |
| Orbital Shaking Function | Yes, with acoustic-dampened motor and vibration-isolated platform |
| Waste Bottle Capacity | Standard 2 L, with full-level optical sensor and audible/visual alarm |
| Brand | Autobio |
|---|---|
| Model | AutoMolec 3000 |
| Origin | Henan, China |
| Sample Throughput | 3000 tests/day |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.5 °C |
| Detection Limit | <100 copies/mL |
| Cycle Time per Sample | ~100 min |
| Compliance | ISO 13485, CE-IVD, NMPA Registration No. 20223400123 |
| Brand | Autobio |
|---|---|
| Model | AutoLumo A2000Plus |
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Yes |
| Throughput | 200 samples/hour |
| Sample Input Mode | Rotary Disc Loader |
| Sample Types Supported | Serum, Plasma, Whole Blood (with preprocessing), Urine |
| Reagent Loading | Continuous, On-the-Fly |
| Reaction Vessel Handling | Tipless, Inverted Cup Dispensing |
| Magnetic Separation Technology | High-Efficiency Dual-Stage Wash |
| Software Compliance | FDA 21 CFR Part 11–Ready Audit Trail, GLP/GMP-Compliant Data Archiving |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | AutoChem B861 |
| Price Range | USD 150–15,000,000 (FOB) |
| Detection Principle | Post-Dispensing Spectrophotometry with 16-Wavelength Optical System |
| Sample Throughput | Up to 800 tests/hour (typical configuration) |
| HbA1c Capability | Whole Blood Direct Measurement |
| Mechanical Durability | >5,000,000 cycles validated under continuous-load fatigue testing |
| Key Components | Imported precision optical modules, high-accuracy peristaltic pumps, and temperature-stabilized reaction cuvettes |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | Autostreak S1800 |
| Price Range | USD 140,000 – 210,000 (FOB) |
| Instrument Type | Fully Automated |
| Sample Type | Liquid (including sputum, broth cultures, urine supernatants) |
| Throughput | 180 Petri Dishes per Hour |
| Liquefaction Time | ≤5 min (sputum) |
| Streaking Time | ≤60 sec per 3 plates |
| Biosafety Level | Integrated Class II Biological Safety Cabinet Architecture |
| Filtration | HEPA H14 (99.995% @ 0.3 µm) |
| Decontamination | Automated UV-C (254 nm) cycle with timer-based scheduling |
| Consumables | Disposable sterile tips and single-use inoculation brushes |
| LIS Integration | ASTM E1384 / HL7 v2.x compliant interface |
| Software Compliance | Audit trail, user access control, electronic signature support per FDA 21 CFR Part 11 requirements |
| Brand | Autobio |
|---|---|
| Model | BC120 |
| Capacity | 120-bottle dual-chamber configuration (2 × 60 positions) |
| Detection Principle | Non-invasive colorimetric CO₂ sensing |
| Incubation Temperature Control | Precise ±0.3 °C stability |
| Detection Interval | Continuous monitoring every 10 minutes |
| Sample Handling | Barcode-scanned, anonymous & delayed-loading compatible |
| Regulatory Compliance | Designed to support CLIA, CAP, and ISO 15189-aligned workflows |
| Software | Integrated analysis management software with graphical growth curve visualization, audit trail, and LIS connectivity (HL7 v2.x, ASTM E1384) |
| Alarm System | Audible, visual, and electronic alerts |
| User Interface | Graphical中文界面 → English: Graphical English-language UI with intuitive icon-driven workflow (optional multilingual localization) |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Autolas B-1 Series |
| Quotation | Upon Request |
| Typical Configuration | Four Analyzers (Flexible Combination of Clinical Chemistry and Immunoassay Modules) |
| Throughput | Clinical Chemistry — 2000 tests/hour (excluding electrolytes) |
| Assay Menu | 160 magnetic microparticle-based chemiluminescent immunoassays across 12 disease categories |
| Sample Positions | ≥150 |
| Reagent Positions | >20 for immunoassay |
Show next
