Empowering Scientific Discovery

Zhuhai OMEC Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOMEC
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelNS-90
PriceUpon Request
Particle Size Range0.3 – 5000 nm
Size Measurement Repeatability≤ ±1% (NIST-traceable latex standards)
Temperature Control Range0–90°C (optional 120°C thermostatic cell)
Temperature Stability±0.1°C
Correlator Sampling Time25 ns – 8000 s
Number of Autocorrelation Channels>4000
Primary Measurement PrincipleDynamic Light Scattering (DLS) at 90° scattering angle
Secondary Measurement PrincipleStatic Light Scattering (SLS)
Sample Volume Requirement0.3–5000 nm (size range)
Zeta Potential Measurement CapabilityNot integrated (ALL = N/A in this model)
Typical Measurement Duration~10 seconds per run
Molecular Weight Range<1000 Da – 2×10⁷ Da
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOMECK
OriginGuangdong, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelNS-90 Plus
Particle Size Range0.3 nm – 10 µm
Size Measurement Repeatability≤ 1% (NIST-traceable latex standards)
Temperature Control Range0 – 120 °C
Temperature Stability±0.1 °C
Detection Angle90°
Measurement PrincipleDynamic Light Scattering (DLS) and Static Light Scattering (SLS)
Minimum Sample Volume20 µL
Sample Concentration Range≤ 1 mg/mL (sample-dependent)
Measurement Time (per sub-run)1.68 s
Molecular Weight Range (DLS-derived)980 – 2×10⁷ Da
Molecular Weight Range (SLS Debye plot)342 – 2×10⁷ Da
Laser SourceHe-Ne gas laser, 632.8 nm, 4 mW
DetectorAvalanche Photodiode (APD), QE ≥ 80% @ 632.8 nm
Correlator>4000 channels, 10¹¹ linear dynamic range, minimum sampling interval: 25 ns
ComplianceCFDA GMP Annex on Computerized Systems (audit trail, role-based access control, electronic signature)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOMEC
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelOMEC NS-90
PriceUpon Request
Particle Size Range0.3 – 5000 nm
Size Measurement Repeatability≤ ±1% (NIST-traceable latex standards)
Temperature Control Range0°C – 90°C (optional 120°C thermostatic cell)
Temperature Stability±0.1°C
Correlator Sampling Time25 ns – 8000 s
Number of Autocorrelation Channels>4000
Primary Measurement PrincipleDynamic Light Scattering (DLS) at 90° detection angle
Secondary Measurement PrincipleStatic Light Scattering (SLS)
Sample Volume Requirement0.3–5000 nm (size range)
Zeta Potential CapabilityNot integrated (ALL = N/A)
Typical Measurement Duration~10 minutes per run
Molecular Weight Range<1000 Da – 2×10⁷ Da