- All
- Favorite
- Popular
- Most rated
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electrical Resistance (Coulter) Particle Counter |
| Measurement Principle | Coulter Principle (Electrical Sensing Zone) |
| Particle Size Range | 1–256 µm |
| Repeatability Error | <2% |
| Analysis Time | 15 seconds per sample |
| Channel Resolution | 8192 channels |
| Output Parameters | Particle size distribution table & curve, D10/D50/D90, mean diameter, median diameter, standard deviation, coefficient of variation, specific surface area, total particle count |
| Key Hardware Features | Discrete measurement cell + PC-based acquisition architecture, high-precision pulse peak detection circuitry, solid-state pressure sensor for vacuum control, optoelectronic liquid level sensing, automated aperture clearing function |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | RC-2200 |
| Instrument Type | Electrical Resistance (Coulter) Particle Counter |
| Standard Compliance | GB/T 29025–2012, ISO 13319-1:2021 |
| Measurement Principle | Aperture Impedance (Coulter Principle) |
| Dynamic Range | 0.6–256 µm (down to 0.4 µm under optimal conditions) |
| Channel Resolution | 8192 detection channels |
| Repeatability | ≤1% (D₅₀ deviation on certified reference material) |
| Pulse Latency | 5 µs |
| Signal-to-Noise Ratio | 140 dB |
| Sample Introduction | Electrolyte-diluted suspension, stir-or-static mode |
| Sampling Control Modes | Fixed time / Fixed volume / Fixed particle count |
| Test Duration | ~15 s (typical) |
| Data Output | Size distribution table & curve, D₁₀/D₅₀/D₉₀, mean diameter, standard deviation, coefficient of variation, specific surface area, total particle count, frequency histogram |
| Power Supply | 200–240 V AC, 50 Hz |
| Dimensions (W×D×H) | 300 × 370 × 450 mm |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electrical Resistance (Coulter) Particle Counter |
| Model | RC-3000 |
| Measurement Principle | Coulter principle (electrical sensing zone) |
| Particle Size Range | 1–256 µm |
| Repeatability Error | <2% |
| Analysis Time | 15 s per sample |
| Channel Resolution | 8192 channels |
| Output Parameters | Particle size distribution table & curve, D10/D50/D90, mean diameter, standard deviation, coefficient of variation, specific surface area, total particle count |
| Key Hardware | ARM-based integrated architecture, precision pulse peak detection circuitry, digital pressure sensor for vacuum control, optoelectronic liquid level sensing, automated aperture clearing system, auto-balancing conductivity compensation circuit |
Show next