BXP-65S Biochemical Incubator
| Brand | — |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | BXP-65S |
| Price | Upon Request |
| Temperature Range | RT+5 °C to 100 °C |
| Temperature Uniformity (at 60 °C) | ±0.6 °C |
| Temperature Fluctuation (at 60 °C) | ±0.3 °C |
| 30-Second Recovery Time (at 60 °C) | 14 min |
| Heating Time to 60 °C | 16 min |
| Rated Power | 0.55 kW |
| Inner Chamber Dimensions (W×D×H) | 410 × 350 × 450 mm |
| External Dimensions (W×D×H) | 575 × 608 × 637 mm |
| Standard Shelves | 2 (max. 5) |
| Stackable | Yes (up to 2 units) |
| Interface Ports | 2 × RS-485, 1 × USB |
Overview
The BXP-65S Biochemical Incubator is an engineered-for-precision environmental control system designed for consistent, traceable, and contamination-controlled microbial cultivation, enzyme activity assays, cell line maintenance, and biochemical reaction studies. Operating on forced-air convection with independently adjustable airflow velocity and programmable fresh-air exchange, the unit maintains stable thermal conditions across its full operating range—from ambient +5 °C up to 100 °C. Its core architecture integrates a pre-heating chamber that ensures uniform air mixing prior to entering the working chamber, minimizing thermal gradients and accelerating temperature stabilization. The all-aluminum-foil-sealed 50 mm insulation layer—combined with zero-fiber-glass leakage construction—meets stringent cleanroom compatibility requirements (ISO Class 5 / ISO 14644-1 Grade A equivalent for internal air quality when equipped with optional HEPA filtration). Dual-door design features a full-view tempered glass inner door, enabling non-intrusive observation without compromising chamber integrity or thermal stability.
Key Features
- 5-inch high-resolution capacitive touchscreen interface with BRIGHT II intelligent control system, supporting real-time auto-compensation for ambient temperature and humidity fluctuations
- Multi-stage programmable operation: up to 30 segments per program, 99 cycles total; includes ramp/soak profiles with user-defined heating and cooling rate control
- 6-level adjustable fan speed and 10-stage exhaust damper control for precise oxygenation management across diverse microbial and cellular culture requirements
- Dual independent overtemperature protection: primary sensor-based cut-off + secondary mechanical thermostat for fail-safe operation
- Comprehensive data logging: 1 million records stored internally; exportable via USB in immutable .csv format with timestamp, setpoint, actual temperature, alarm status, and operator ID (where multi-level password authentication is enabled)
- Multi-tiered access control: three-level password system (operator, technician, administrator) restricting parameter modification, calibration, and data export functions
- Calendar-based scheduling with up to 10 concurrent预约 events, supporting unattended start/stop and automatic mode switching
Sample Compatibility & Compliance
The BXP-65S accommodates standard microbiological vessels—including Petri dishes, test tubes, flasks, and multi-well plates—on fully adjustable drawer-type shelves (2 standard, expandable to 5). Its interior chamber is constructed from electropolished stainless steel (AISI 304), resistant to corrosion from common sterilants (e.g., 70% ethanol, hydrogen peroxide vapor, and low-concentration sodium hypochlorite). Optional inlet and outlet HEPA filters (rated at ISO 14644-1 Class 5 / 100-grade efficiency) ensure particulate-free air supply and safe exhaust handling of biosafety level 1 (BSL-1) cultures. The incubator complies with IEC 61010-1:2010 for laboratory equipment safety and supports audit-ready documentation workflows aligned with GLP, GMP, and FDA 21 CFR Part 11 requirements when configured with FDA-compliant monitoring software and electronic signature modules.
Software & Data Management
Data integrity is enforced through time-stamped, tamper-evident logging with embedded checksum validation. Internal storage retains temperature history, alarm logs (including cause, duration, and acknowledgment status), and user action traces. USB export generates read-only files compliant with ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available). Optional PC-based monitoring software offers remote real-time visualization, configurable alarm notifications (email/SMS via GPRS add-on), trend analysis, and automated report generation (PDF/Excel) for regulatory submissions. Audit trail functionality records all configuration changes, user logins, and data exports with IP address and session timestamps.
Applications
- Standardized bacterial and fungal cultivation (e.g., E. coli, S. aureus, A. niger) per ISO 8573-7, USP , and EP 2.6.12
- Enzyme kinetics and thermostability profiling under controlled thermal ramps
- Long-term stability testing of biopharmaceutical intermediates and excipients
- Cell viability assays requiring precise O2/CO2-independent aerobic environments
- Quality control of raw materials and finished products in food, cosmetic, and pharmaceutical manufacturing
- Environmental simulation for accelerated aging and shelf-life prediction studies
FAQ
Does the BXP-65S support validation protocols required for GxP environments?
Yes—when equipped with FDA Edition monitoring software, calibrated reference sensors, and enabled audit trail/logging, it meets baseline requirements for IQ/OQ/PQ execution and 21 CFR Part 11 compliance.
Can temperature uniformity be verified across the entire chamber volume?
Yes—the chamber geometry and airflow design enable verification per ISO 14644-3 Annex B or ASTM E2873 using a minimum of 9 thermocouple probes placed at standardized locations.
Is remote monitoring and alarm notification available out-of-the-box?
Remote viewing requires optional PC software; SMS alerts require the GPRS module add-on and carrier-configured SIM card.
What is the maximum allowable load for stacked units?
Two units may be safely stacked provided floor loading capacity exceeds 120 kg/m² and ambient ventilation clearance (≥100 mm rear/side) is maintained for both units.
Are calibration certificates traceable to national standards included?
Factory calibration reports are supplied; NIST-traceable certificates are available upon request as a service option.