Empowering Scientific Discovery

WIGGENS BioVac630B Six-Position Stainless Steel Vacuum Filtration System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand WIGGENS
Origin Germany
Model BioVac630B
Pump Flow Rate 58 L/min
Ultimate Vacuum ≤150 mbar
Waste Bottle Capacity 3000 mL (Polycarbonate)
Number of Filtration Positions 6
Filtration Plate Material SS316 Stainless Steel
Filter Membrane Diameter 47 mm or 50 mm
Filter Flask Volumes 100 mL, 300 mL, 500 mL (compatible)
Effective Filtration Area per Position 9.6 cm²
Tubing Inner Diameter 8 mm
Sterilization Compatibility Autoclavable, Dry Heat (up to 250 °C), Flame-Sterilizable

Overview

The WIGGENS BioVac630B is a six-position vacuum filtration system engineered for high-integrity, repeatable liquid and microbial sample processing in regulated laboratory environments. Designed around Couette-type vacuum-driven separation principles, the system enables simultaneous, independent filtration across six discrete channels using precisely engineered SS316 stainless steel filtration plates. Its architecture eliminates elastomeric gaskets and polymer-based sealing interfaces at critical contact points—replacing them with metal-to-metal rotary latch couplings and magnetically stabilized funnel mounts—to ensure long-term dimensional stability, chemical resistance, and full compatibility with sterilization protocols required under ISO 13485, USP , and GLP-compliant workflows. The integrated diaphragm vacuum pump delivers a stable flow rate of 58 L/min with an ultimate vacuum of ≤150 mbar, sufficient to support rapid filtration of viscous biological suspensions, aggressive solvents, and particulate-laden process streams without membrane collapse or channel clogging.

Key Features

  • SS316 Filtration Plate Assembly: All wetted surfaces—including plate body, sealing rings, and funnel retention hardware—are fabricated from electropolished AISI 316 stainless steel, providing exceptional resistance to chloride-induced pitting, organic acids, and oxidizing agents commonly encountered in pharmaceutical QC and environmental testing.
  • Independent Channel Control: Each of the six filtration positions features a dedicated on/off valve with tactile feedback and positive shut-off, enabling selective operation without cross-contamination or pressure imbalance between active and idle channels.
  • Rotary Snap-Lock Interface: The filtration plate employs a precision-machined rotary coupling mechanism that achieves leak-tight sealing via angular torque engagement—not clamps or threaded adapters—reducing setup time by >60% versus conventional manifold systems while maintaining reproducible compression force across repeated cycles.
  • Magnetic Funnel Mounting: BioVac630B-compatible funnels (including optional 47 mm and 50 mm variants) integrate rare-earth neodymium magnets into their base flanges, ensuring centric alignment and vibration-damped seating on the SS316 plate without auxiliary fixtures or alignment jigs.
  • Modular Flask Compatibility: Supports interchangeability among 100 mL, 300 mL, and 500 mL borosilicate glass or polycarbonate filter flasks—each rated for ≥0.8 bar differential pressure—allowing volume scalability without revalidation of filtration parameters.

Sample Compatibility & Compliance

The BioVac630B accommodates standard 47 mm and 50 mm diameter membranes (e.g., mixed cellulose ester, PVDF, PTFE, and nylon) and maintains uniform flow distribution across all six positions within ±3.2% CV (coefficient of variation) when tested per ASTM D2873-22. Its construction complies with EU Directive 2014/30/EU (EMC), IEC 61010-1:2010 (safety), and FDA 21 CFR Part 11 requirements for audit-trail-capable instrumentation when paired with WIGGENS’ optional BioLog software suite. All components are validated for 100+ autoclave cycles at 121 °C / 15 psi, dry heat sterilization at 180 °C for 2 hours, and direct flame pass-through (per ISO 14644-1 Class 5 cleanroom maintenance protocols).

Software & Data Management

When integrated with the WIGGENS BioLog v3.2 platform (optional), the BioVac630B supports electronic batch records, user-access-controlled method storage, and time-stamped event logging—including valve actuation, vacuum pressure excursions, and runtime duration per channel. Data export conforms to ASTM E2500-21 for raw data integrity and supports CSV, PDF, and XML formats compliant with LIMS ingestion standards. Audit trails meet ALCOA+ criteria and include immutable operator ID, timestamp, action type, and pre-/post-change values for all configurable parameters.

Applications

  • Membrane filtration assays for E. coli, Pseudomonas aeruginosa, and Staphylococcus aureus per ISO 7218 and AOAC 977.27
  • Particulate removal from HPLC mobile phases and cell culture media prior to sterile filtration
  • Residual solvent recovery and catalyst separation in fine chemical synthesis
  • Airborne particulate collection using NIOSH-approved 37-mm cassettes (with adapter kit)
  • Pre-concentration of low-biomass environmental water samples for qPCR-based pathogen detection

FAQ

Is the BioVac630B compatible with aggressive solvents such as chloroform or concentrated nitric acid?
Yes—the SS316 filtration plate, polycarbonate waste bottle, and fluorosilicone O-rings resist prolonged exposure to halogenated hydrocarbons, strong mineral acids, and caustic bases per ASTM G128-20 corrosion resistance guidelines.
Can the system be validated for GMP manufacturing environments?
Yes—full IQ/OQ documentation packages, including calibration certificates traceable to NIST standards, are available upon request; system design supports installation qualification per Annex 15 of the EU GMP Guide.
What is the maximum operating temperature for the filtration plate during dry-heat sterilization?
The SS316 plate retains mechanical integrity and surface passivation up to 250 °C for durations ≤4 hours, consistent with EN 285:2015 steam sterilizer validation requirements.
Does each filtration position maintain identical vacuum distribution under load?
Yes—pressure mapping conducted per ISO 5355:2019 confirms ≤±12 mbar deviation across all six ports at 58 L/min flow, ensuring equivalent filtration kinetics regardless of channel utilization pattern.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0