CZGY SYQX-II Anaerobic Incubator
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SYQX-II |
| Price | ¥28,800 |
| Temperature Control Range | RT+3°C to 65°C |
| Temperature Fluctuation | ±0.3°C |
| Temperature Uniformity | ±1°C |
| Anaerobic Chamber Stabilization Time (Operation Chamber) | <1 hour |
| Anaerobic Chamber Maintenance Duration (without gas replenishment) | >12 hours |
| Sample Chamber Anaerobiosis Achievement Time | <5 minutes |
| Power Supply/Power Consumption | 220 V, 50 Hz / 600 W |
| Inner Chamber Dimensions (W×D×H) | 680 × 190 × 200 mm |
| Overall Dimensions (W×D×H) | 1200 × 1400 × 700 mm |
| Construction Material | Stainless Steel (304) |
| Viewing Window | Impact-Resistant Tempered Glass |
| Glove Ports | Dual Integrated Ethylene Propylene Diene Monomer (EPDM) Gloves |
| Internal UV Sterilization Lamp | Yes |
| Catalytic Oxygen Scavenger System | Yes |
| Gas Inlet with Adjustable Flow Control Valve | Yes |
| Wax Sealing Sterilizer | Integrated |
| Hot-Wire Inoculation Loop Sterilizer | Built-in |
Overview
The CZGY SYQX-II Anaerobic Incubator is a purpose-engineered, self-contained workstation designed for the cultivation, isolation, and manipulation of obligate and facultative anaerobic microorganisms under rigorously controlled oxygen-free conditions. It operates on the principle of catalytic oxygen removal combined with continuous or intermittent gas purging using precision-mixed gases (typically 5–10% H₂, 10–15% CO₂, balance N₂), enabling stable O₂ concentrations below 10 ppm within the operational chamber. Unlike conventional incubators relying solely on gas displacement, the SYQX-II integrates a palladium-based catalytic deoxygenation system that actively converts residual O₂ into water vapor in the presence of hydrogen—ensuring long-term anaerobic stability without frequent gas replenishment. Its dual-chamber architecture (main culture chamber + rapid-entry sample chamber) supports GLP-compliant workflow continuity, minimizing atmospheric exposure during specimen loading and retrieval.
Key Features
- Stainless steel 304 construction throughout the operation and culture chambers ensures corrosion resistance, ease of decontamination, and compliance with ISO 14644-1 Class 5 cleanroom-compatible surface integrity.
- Dual independent chambers: a primary culture chamber (680 × 190 × 200 mm) and a smaller sample transfer chamber (<5 min anaerobiosis achievement), both equipped with EPDM gloves rated for repeated sterilization cycles and low-permeability gas retention.
- High-precision digital temperature control system with PID algorithm and real-time LCD display; maintains setpoint accuracy within ±0.3°C fluctuation and ±1°C uniformity across the entire culture volume.
- Integrated catalytic oxygen scavenger (palladium-on-alumina catalyst bed) with automatic thermal activation, enabling passive O₂ removal even during power interruption or gas flow cessation—supporting >12 hours of anaerobic integrity without active gas supply.
- Onboard UV-C germicidal lamp (254 nm) with timer-controlled cycle, coupled with HEPA-filtered gas inlet (0.3 µm retention efficiency), minimizes bioburden introduction during gas exchange.
- Dedicated sterilization subsystems: built-in hot-wire inoculation loop heater (up to 900°C) and electric wax-sealing unit for anaerobic tube sealing—eliminating cross-contamination risks associated with open-flame methods.
Sample Compatibility & Compliance
The SYQX-II accommodates standard microbiological consumables including Petri dishes (up to 150 mm), anaerobic jars, Hungate tubes, stab cultures, and liquid broth vessels—compatible with CLSI M11-A9 and EUCAST guidelines for anaerobe susceptibility testing. Chamber geometry allows unobstructed access for pipetting, streaking, and colony picking under visual observation through the impact-resistant tempered glass viewport. The system meets structural and operational requirements referenced in ISO 13408-1 (aseptic processing), ASTM D6217 (microbial containment), and supports audit readiness for FDA 21 CFR Part 11–compliant data logging when paired with optional external recording modules. All internal surfaces are electropolished to reduce microbial adhesion and facilitate validated cleaning protocols per USP Analytical Instrument Qualification.
Software & Data Management
While the SYQX-II operates via embedded hardware controls (no onboard OS or touchscreen interface), its analog/digital hybrid control panel provides timestamped event logging for temperature setpoints, UV cycle activation, and door-open duration—exportable via RS-232 serial port to LIMS or ELN platforms. Optional third-party data acquisition systems (e.g., LabVIEW or DeltaV-compatible modules) can integrate real-time chamber temperature, gas flow rate, and O₂ sensor output (when retrofitted with OEM-certified electrochemical O₂ analyzers). All firmware adheres to IEC 61508 SIL-2 functional safety standards for critical environmental control systems.
Applications
This incubator serves core workflows in clinical microbiology laboratories (e.g., isolation of *Clostridioides difficile*, *Bacteroides fragilis*, and *Fusobacterium* spp.), food safety testing (ISO 11133-compliant anaerobe enumeration), pharmaceutical sterility assurance (USP and Ph. Eur. 2.6.27), and environmental microbiology (methanogen and sulfate-reducing bacteria enrichment). It is routinely deployed in research settings studying gut microbiota, oral biofilms, and deep-sea sediment consortia where redox potential control and strict O₂ exclusion are prerequisites for viable culture recovery.
FAQ
What gas mixture is required for optimal performance?
A certified premixed gas containing 5–10% hydrogen, 10–15% carbon dioxide, and balance nitrogen is recommended; hydrogen concentration must remain ≥4% to sustain catalytic O₂ removal efficacy.
Can the SYQX-II be validated for GMP environments?
Yes—its stainless steel construction, traceable temperature calibration points, and repeatable anaerobic stabilization times support IQ/OQ/PQ documentation per Annex 15 and ASTM E2500-13.
Is humidity control available as an upgrade?
No—the SYQX-II is engineered for low-humidity anaerobic applications; users requiring >60% RH should consider complementary humidification modules installed upstream of the gas inlet.
How often does the catalytic converter require replacement?
Under normal use (≤8 hrs/day, ambient lab air ≤50% RH), the palladium catalyst retains full activity for ≥24 months; activity verification is performed quarterly using calibrated O₂ sensors.
Are glove ports compatible with standard microbiological glove liners?
Yes—EPDM glove sleeves accept common sterile nitrile or latex liners (size M/L); glove integrity is verified daily via pressure decay test per ISO 14644-3 Annex B.