Empowering Scientific Discovery

WIGGENS Fuego SCS Blue Classic Series Bunsen Burner

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand WIGGENS
Origin Germany
Model Fuego SCS
Max. Flame Temperature 1350 °C (LPG), 1300 °C (Natural Gas)
Gas Consumption 70 g/h
Gas Supply Pressure LPG 20–50 mbar, Natural Gas E/LL 18–25 mbar
Power Input 100–240 V AC, 50/60 Hz, ≤0.3 A
Rated Power 1 kW
Dimensions 103 × 49 × 130 mm
Weight 700 g
Safety Compliance DIN EN 61000-6-3, DIN EN 61000-6-4, CE, EEC
Control Interface Microprocessor-based LCD with graphical navigation, IR sensor, rotary knob, optional footswitch (order separately)

Overview

The WIGGENS Fuego SCS Blue Classic Series Bunsen Burner is an engineered solution for laboratories requiring precise, repeatable, and high-temperature open-flame operation under stringent safety and ergonomics standards. Unlike conventional burners relying solely on mechanical air-gas mixing, the Fuego SCS integrates aerodynamic nozzle geometry—designed using fluid-dynamic principles—to minimize ambient air turbulence and stabilize the stoichiometric combustion zone. This results in a consistent, non-luminous blue flame with optimal thermal profile and minimal CO emission. Its maximum operating temperature of 1350 °C (with LPG) or 1300 °C (with natural gas) meets ISO 15190:2020 requirements for microbiological sterilization cycles and ASTM E119-compliant flame testing protocols. The burner operates as a standalone thermal source without external gas regulators or secondary ignition hardware—its integrated piezoelectric igniter and flame-sensing thermocouple ensure reliable cold-start performance and real-time flame integrity verification.

Key Features

  • Aerodynamically optimized burner head with 23 mm orifice diameter ensures laminar flow stability and uniform flame geometry across variable gas pressures (LPG: 20–50 mbar; NG: 18–25 mbar)
  • SCS (Safety Control System) — a proprietary microprocessor-controlled architecture continuously monitors gas supply continuity, flame presence via thermocouple feedback, surface temperature at the burner head, and thermal cutoff thresholds (auto-shutdown at >180 °C surface temp)
  • BHC (Burner Head Check) algorithm detects physical obstructions (e.g., liquid residue or particulate blockage) and verifies correct installation orientation prior to ignition sequence initiation
  • Multi-mode activation: rotary knob with tactile switch (press-to-ignite, turn-to-adjust), infrared remote controller (timer range: 1 s–2 h), and optional wired footswitch (standard mode or timed actuation)
  • Thermally insulated stainless steel housing (one-piece deep-drawn construction) with external heat shielding; no sharp edges for safe handling and simplified decontamination
  • Adjustable tilt mechanism—user-selectable left/right inclination via spring-loaded base plate—enables angled flame positioning without compromising structural rigidity or gas seal integrity
  • Integrated graphical LCD interface with self-guided navigation menu supports multilingual configuration and real-time status display (gas type, flame status, timer countdown, fault codes)

Sample Compatibility & Compliance

The Fuego SCS is compatible with standard laboratory glassware (e.g., test tubes, Petri dishes, inoculation loops) and metallic sterilization tools (e.g., wire loops, spatulas). Its flame stability enables reproducible dry-heat sterilization cycles per ISO 14644-1 Class 5 cleanroom protocols and USP compounding environment validation. The device conforms to European electromagnetic compatibility directives (DIN EN 61000-6-3/6-4), low-voltage safety regulation (2014/35/EU), and carries CE and EEC markings. It is designed for use in GLP- and GMP-regulated environments where audit-ready operational logs are required—though it does not include FDA 21 CFR Part 11-compliant electronic record functionality unless paired with external data acquisition systems.

Software & Data Management

The Fuego SCS features embedded firmware with non-volatile memory storing up to 100 operational events (ignition timestamp, duration, gas type selected, fault triggers). While it lacks cloud connectivity or API interfaces, its IR remote controller supports programmable timer sequences that can be documented manually in lab notebooks or imported into LIMS via CSV export from connected PCs (using optional RS-232 adapter kit, order no. 6.000.405). All safety-critical alerts—including residual heat warning (audible beep + LED indicator), flame-out detection, and overpressure condition—are logged with ISO 8601 timestamps and accessible via service mode diagnostics.

Applications

  • Routine sterilization of inoculation loops, needles, and forceps in microbiology and cell culture labs
  • Flame polishing of glass capillaries and Pasteur pipettes
  • Controlled open-flame heating during chemical synthesis (e.g., Schlenk line maintenance, solvent evaporation)
  • Calibration reference source for pyrometric validation of furnace temperature profiles
  • Education and training modules on combustion stoichiometry, flame spectroscopy, and thermal hazard assessment
  • Field-deployable flame source for environmental sampling stations requiring portable high-temperature treatment

FAQ

What gas types are supported, and what pressure ranges must be maintained?
The Fuego SCS accepts liquefied petroleum gas (LPG) at 20–50 mbar or natural gas (E/LL grade) at 18–25 mbar. Use only certified laboratory-grade gas supplies meeting EN 437 specifications.
Is the footswitch included in the standard delivery package?
No—the wired footswitch (order no. 6.000.402) and wireless RF footswitch (for Fuego Basic RF variant) are optional accessories and must be ordered separately.
Can the burner be used for extended continuous operation?
Yes—engineered for duty cycles up to 8 hours per day, provided ambient temperature remains below 35 °C and ventilation meets DIN 1946-7 airflow requirements (≥12 air changes/hour).
Does the unit support external temperature feedback control?
An optional external Pt100 sensor input (accessory port) enables closed-loop temperature regulation of heated media within the range of +35 °C to +350 °C, though this function requires separate configuration via service menu.
How is residual heat indicated after shutdown?
A dual-mode alert activates: amber LED pulsing + intermittent audible tone (3 kHz, 0.5 s ON / 1.5 s OFF) until burner head surface cools below 60 °C, verified by integrated thermistor array.