PerkinElmer Clarus 500 Gas Chromatograph with TurboMatrix Autosampler
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | Clarus 500 |
| Instrument Type | Gas Chromatograph (GC) |
| Detector Configuration | FID & ECD |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished & Fully Tested |
| Regulatory Compliance | Meets ASTM D3606, ISO 10301, and USP <621> for GC method execution |
Overview
The PerkinElmer Clarus 500 Gas Chromatograph with TurboMatrix autosampler is a high-performance, benchtop analytical system engineered for precision, reproducibility, and operational efficiency in regulated and research laboratories. Built on PerkinElmer’s proven GC architecture, the Clarus 500 employs capillary column separation coupled with dual-detector capability—specifically flame ionization detection (FID) and electron capture detection (ECD)—to deliver quantitative accuracy across volatile and semi-volatile organic compounds. Its microprocessor-controlled oven provides precise temperature ramping (0.1 °C increments), rapid heating/cooling cycles (<3.5 min from 300 °C to 50 °C), and isothermal stability of ±0.01 °C—critical for method transfer and retention time reproducibility. The integrated TurboMatrix autosampler enables unattended analysis of up to 160 samples with programmable vial agitation, syringe wash routines, and customizable injection volumes (0.1–100 µL), supporting both split and splitless modes per ASTM D5504 and EPA Method 8260D.
Key Features
- Full-color, touchscreen graphical user interface (GUI) with intuitive navigation and real-time instrument status monitoring
- Programmable oven with dual-zone temperature control and active cooling for accelerated cycle times
- Dual-detector configuration: FID (detection limit ≤ 1.8 pg C/s for n-decane) and ECD (detection limit ≤ 0.005 pg/mL for γ-HCH), enabling trace-level halogenated compound analysis
- TurboMatrix autosampler with robotic arm positioning accuracy of ±0.1 mm and thermal equilibration control for consistent vapor-phase injection
- Onboard diagnostics including leak detection, pressure sensor calibration verification, and detector baseline stability logging
- Modular design supporting future upgrades—including optional nitrogen phosphorus detector (NPD), mass selective detector (MSD), or headspace sampler integration
Sample Compatibility & Compliance
The Clarus 500 GC is validated for use with standard fused-silica capillary columns (0.1–0.53 mm ID, up to 60 m length) and accommodates common stationary phases (e.g., DB-5ms, HP-INNOWax, DB-VRX). It supports liquid, gas, and headspace-derived samples, with inlet configurations compatible with septum purge, split/splitless, and direct injection modes. The system meets essential regulatory requirements for GLP and GMP environments: all method parameters, sequence logs, and audit trails are timestamped and exportable in CSV or PDF format. When operated with PerkinElmer’s TotalChrom software (v6.3.1 or later), it supports 21 CFR Part 11-compliant electronic signatures, user role-based access control, and secure data archiving—facilitating FDA and EMA inspection readiness.
Software & Data Management
Data acquisition and processing are performed via PerkinElmer TotalChrom Chromatography Data System (CDS), which provides full method development tools, peak integration algorithms (including valley-to-valley and tangent skim), and customizable reporting templates. Raw data files (.chd) are stored in a relational database structure with automatic backup scheduling. The software includes built-in compliance features such as electronic lab notebook (ELN) integration, audit trail review functionality, and automated recalibration alerts. All instrument control commands and parameter changes are logged with operator ID, timestamp, and reason-for-change fields—ensuring full traceability per ISO/IEC 17025:2017 clause 7.7.
Applications
This refurbished Clarus 500 GC system is routinely deployed in environmental testing (e.g., pesticide residue screening in soil/water per EPA SW-846), petrochemical QA/QC (hydrocarbon fingerprinting, benzene/toluene/xylenes quantification), pharmaceutical impurity profiling (ICH Q2(R2)-aligned validation), and food safety analysis (fatty acid methyl ester profiling, solvent residue testing). Its dual-FID/ECD configuration makes it especially suitable for simultaneous hydrocarbon and organochlorine pesticide analysis in a single run—reducing turnaround time without compromising sensitivity or selectivity.
FAQ
Is this instrument fully refurbished and performance-verified?
Yes. Each unit undergoes a comprehensive refurbishment protocol including column oven calibration, detector sensitivity verification, carrier gas flow optimization, and full system leak testing. A detailed Certificate of Performance Verification is provided with shipment.
What documentation accompanies the system?
You receive original PerkinElmer hardware manuals, factory service records, calibration certificates, and a signed refurbishment report. Software license transfer documentation is included where applicable.
Can this GC be integrated into an existing LIMS environment?
Yes. TotalChrom supports ODBC-compliant data export and can be configured for direct LIMS interfacing via ASTM E1394 or HL7 messaging protocols.
Does the 6-month warranty cover labor and parts?
Yes—the warranty covers all components, labor, and remote technical support for hardware-related failures under normal operating conditions.
Are consumables and spare parts available?
All OEM consumables—including liners, septa, ferrules, and detector components—are stocked and available with same-day shipping. Extended service contracts are also offered post-warranty.