Empowering Scientific Discovery

PerkinElmer AutoSystem GC Gas Chromatograph (Refurbished)

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PerkinElmer
Origin USA
Model AutoSystem GC
Instrument Type Gas Chromatograph
Year of Manufacture ~2016–2018 (7-year-old unit)
Warranty 6 months
Configuration Capillary/Split-Splitless Inlet, Programmable Temperature Vaporizing (PTV) Inlet, Cold-On-Column Inlet, Packed Column Inlet, Autosampler, FID/PID/NPD/ECD/TCD/FPD Detectors
Compliance Fully refurbished and functionally validated per ISO/IEC 17025-aligned internal protocol
Software Turbochrom v6.3.2 (or later compatible version)
Delivery Status Ready-to-ship, bench-tested and calibrated

Overview

The PerkinElmer AutoSystem GC is a modular, high-stability gas chromatograph originally engineered for routine and research-grade volatile and semi-volatile organic compound analysis in environmental, pharmaceutical, petrochemical, and forensic laboratories. Designed with a robust oven architecture, precision temperature control (±0.01 °C stability), and dual independent column compartments, the system supports simultaneous method development and multi-detector operation. Its core measurement principle relies on differential partitioning of analytes between a mobile gas phase (helium, hydrogen, or nitrogen carrier) and a stationary phase coated inside fused-silica capillary columns—enabling separation based on volatility, polarity, and molecular interaction. This refurbished unit has undergone full functional validation at SpectraLab Scientific’s ISO/IEC 17025-aligned calibration facility, including leak testing, baseline noise assessment (<0.5 pA RMS for FID), retention time reproducibility (RSD <0.05% over 10 injections), and detector sensitivity verification per ASTM D3699 and EPA Method 8260B protocols.

Key Features

  • Modular inlet system supporting four distinct injection modes: split/splitless capillary, programmable temperature vaporizing (PTV), cold-on-column (COC), and packed-column—ensuring flexibility across sample matrices and volatility ranges.
  • Dual-zone oven design with independent temperature control for column and detector compartments, minimizing thermal interference and improving retention time stability.
  • Integrated autosampler (AS-100 or AS-200 series) with 100-position vial capacity, programmable injection volume (0.1–100 µL), and syringe wash capability—enabling unattended operation for high-throughput QC workflows.
  • Multi-detector compatibility: factory-configured with Flame Ionization Detector (FID), Photoionization Detector (PID), Nitrogen-Phosphorus Detector (NPD), Electron Capture Detector (ECD), Thermal Conductivity Detector (TCD), and Flame Photometric Detector (FPD)—each individually optimized for selectivity and linear dynamic range (e.g., ECD LOD <0.1 pg/mL for chlorinated compounds).
  • Embedded microprocessor-controlled pneumatics with digital pressure tuning (0.1 psi resolution) and real-time flow monitoring—ensuring method transfer fidelity and compliance with USP and ICH Q2(R2) method robustness requirements.

Sample Compatibility & Compliance

The AutoSystem GC accommodates liquid, gaseous, and headspace-derived samples across a broad polarity and volatility spectrum—from C2 hydrocarbons to polyaromatic hydrocarbons (PAHs) and organophosphate pesticides. It meets critical regulatory prerequisites for GLP and GMP environments when operated with Turbochrom software configured for 21 CFR Part 11 compliance (audit trail, electronic signatures, user role management). All refurbished units undergo traceable calibration using NIST-traceable standards (e.g., alkane series for retention indexing, benzene/toluene/ethylbenzene/xylene mixture for resolution verification), and documentation includes Certificate of Functionality, Leak Test Report, and Detector Performance Summary aligned with ISO 17025 Clause 6.5.

Software & Data Management

Turbochrom v6.3.2 (or newer compatible release) provides full instrument control, sequence management, peak integration, library searching (NIST MS Search optional), and report generation. The software supports audit-trail-enabled data acquisition with timestamped parameter changes, user login tracking, and immutable raw data storage (.ch files). Export formats include CSV, PDF, and XML for LIMS integration. Optional modules include Turbochrom Quantitation Plus for automated calibration curve fitting (linear, quadratic, weighted least squares) and Turbochrom Compliance Pack for enhanced 21 CFR Part 11 enforcement—including electronic signature capture, password policy enforcement, and session timeout configuration.

Applications

  • Environmental analysis: VOCs in soil/water per EPA Methods 502.2, 524.2, 8260D; SVOCs per Method 8270E; pesticide residues in food per AOAC 2007.01.
  • Pharmaceutical QC: residual solvent testing per ICH Q3C guidelines; assay purity profiling of active pharmaceutical ingredients (APIs); excipient compatibility studies.
  • Petrochemical testing: hydrocarbon type analysis (HTA) via simulated distillation; sulfur compound profiling in fuels per ASTM D5599 and D6667.
  • Forensic toxicology: detection of drugs of abuse (e.g., amphetamines, cannabinoids) in biological matrices using NPD/ECD/FID tandem configurations.
  • Food & flavor analysis: quantification of off-flavor compounds (e.g., geosmin, 2-methylisoborneol), essential oil composition, and lipid oxidation markers (hexanal, pentanal).

FAQ

Is this instrument fully tested before shipment?
Yes. Each refurbished AutoSystem GC undergoes 72-hour continuous operational validation, including temperature ramp linearity, detector signal-to-noise ratio, retention time reproducibility, and pneumatic integrity testing. A comprehensive Certificate of Functionality is provided with shipment.
Does the system include original PerkinElmer documentation and software licenses?
All units ship with scanned copies of original operator manuals, maintenance guides, and schematics. Turbochrom software is supplied with a valid activation key and installation media; perpetual license rights are retained under PerkinElmer’s refurbished equipment terms.
Can the system be upgraded with modern detectors or interfaces?
Yes—the AutoSystem platform supports hardware retrofits including newer-generation FID electronics, mass-selective detector (MSD) interfaces, and GC×GC modulators. SpectraLab provides engineering consultation for upgrade feasibility and integration path planning.
What consumables and spare parts are recommended for initial operation?
We recommend ordering a starter kit including: 30 m × 0.25 mm × 0.25 µm DB-5ms column, FID jet kit, septa (100 pcs), liner pack (deactivated glass wool), and certified calibration standards (alkane mix, EPA 8260B surrogate mix).
Is on-site installation and qualification support available?
Yes. IQ/OQ documentation packages compliant with ASTM E2500 and EU Annex 15 are available. On-site technician deployment can be arranged globally for installation, operational qualification, and staff training.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0