Empowering Scientific Discovery

WAYEAL AA2300 Flame and Graphite Furnace Atomic Absorption Spectrophotometer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand WAYEAL
Origin Anhui, China
Manufacturer Type Direct Manufacturer
Instrument Type Flame and Graphite Furnace AAS
Monochromator Plane Grating
Optical System Dual-Beam (Optical for Flame / Electronic for GF)
Detector Photomultiplier Tube (PMT)
Background Correction Deuterium Lamp
Detection Limit (Cu, Flame) ≤0.002 μg/mL
Baseline Stability Zero Drift ±0.002 Abs / 30 min

Overview

The WAYEAL AA2300 is a dual-atomization atomic absorption spectrophotometer engineered for high-precision elemental quantification in environmental, pharmaceutical, clinical, food safety, and metallurgical laboratories. Based on the fundamental principle of atomic absorption spectroscopy—where ground-state free atoms in the gaseous phase absorb characteristic wavelengths of light—the AA2300 employs hollow cathode lamp (HCL) excitation and wavelength-selective detection to deliver trace-level metal analysis with robust reproducibility. Its hybrid optical architecture integrates a true dual-beam optical system for flame mode (ensuring real-time correction of source drift and lamp fluctuations) and an electronic dual-beam configuration for graphite furnace operation (enabling rapid background subtraction without mechanical beam modulation). The monolithic aluminum optical platform minimizes thermal and mechanical drift, while the sealed graphite furnace chamber and integrated furnace-viewing camera support precise temperature programming and visual validation of atomization dynamics.

Key Features

  • Integrated dual-atomization system: Parallel-mounted flame and graphite furnace atomizers with <1 s software-triggered mode switching—eliminating manual reconfiguration and reducing cross-contamination risk.
  • 8-position automated lamp turret: Supports simultaneous preheating of up to eight HCLs; includes proprietary encoded lamp recognition via QR-code scanning for unambiguous element identification and method recall.
  • Intelligent safety interlock suite: Real-time monitoring of acetylene pressure (high/low), air pressure, water seal level, flame ignition status, and combustible gas leakage (via certified catalytic sensor); automatic shutdown and purge upon anomaly or power interruption; integrated air buffer tank sustains auxiliary gas flow for ≥5 seconds after power loss.
  • Pneumatic graphite furnace actuation: One-click software control of furnace lid opening/closing; optimized thermal isolation and reduced ambient interference enhance sensitivity and precision in electrothermal atomization.
  • Dual-background correction: Deuterium arc lamp-based correction for structured molecular absorption across broad spectral ranges—validated per ASTM E1947 and ISO 11170 protocols.

Sample Compatibility & Compliance

The AA2300 accommodates aqueous solutions, acid-digested environmental matrices (e.g., soil, wastewater per EPA Method 200.9), biological digests (blood, tissue per CLIA guidelines), and food extracts (per AOAC 984.27). Its flame and graphite furnace configurations comply with regulatory requirements for routine and ultra-trace analysis under USP , FDA 21 CFR Part 11 (with optional audit trail and electronic signature modules), and GLP/GMP environments. The instrument’s baseline stability (±0.002 Abs over 30 min) and Cu detection limit (≤0.002 μg/mL in flame mode) meet or exceed performance criteria specified in ISO 11170 and EN 14802 for heavy metal screening in drinking water and industrial effluents.

Software & Data Management

Controlled by WAYEAL AAS Studio v4.x, the system provides method-driven workflow automation—from lamp selection and wavelength optimization to multi-point calibration, peak integration (area/height), and QC flagging (e.g., drift alerts, signal-to-noise ratio thresholds). All raw spectral data, instrument parameters, and user actions are timestamped and stored in encrypted SQLite databases compliant with ALCOA+ principles. Optional 21 CFR Part 11 add-ons enable role-based access control, electronic signatures, and full audit trail generation—including modification history of calibration curves and sample results—for regulated laboratory submissions.

Applications

  • Environmental monitoring: Quantification of Pb, Cd, Cr, Ni, and As in groundwater, leachates, and airborne particulate matter (PM2.5/PM10) following EPA SW-846 methods.
  • Pharmaceutical quality control: Residual catalyst metal testing (e.g., Pd, Pt, Rh) in active pharmaceutical ingredients per ICH Q2(R2) guidance.
  • Clinical toxicology: Whole-blood lead and urinary cadmium analysis aligned with CDC reference ranges and CLIA proficiency testing standards.
  • Food and agriculture: Multi-element profiling (Fe, Zn, Cu, Mn) in fortified cereals and infant formula per Codex Alimentarius STAN 1-1985.
  • Geochemical exploration: Rapid field-deployable screening of ore concentrates using flame-AAS for base metals (Zn, Cu, Co).

FAQ

What atomization techniques does the AA2300 support?
Flame atomic absorption (FAAS), electrothermal atomic absorption (ETAAS) using graphite furnace, and hydride generation AAS (HG-AAS) for As, Se, Sb, Bi, Te, and Pb.
Is the instrument compatible with third-party data systems?
Yes—AAS Studio supports ASCII and CSV export; optional OPC UA and ASTM E1384-compliant interfaces enable integration with LIMS and ELN platforms.
How is background correction implemented?
Deuterium lamp continuum correction is applied in both flame and graphite furnace modes, with automatic spectral bandwidth adjustment synchronized to slit width settings.
Does the AA2300 meet ISO/IEC 17025 requirements for accredited testing labs?
When operated with documented SOPs, calibrated standards traceable to NIST SRMs, and validated methods per ISO/IEC 17025 Clause 7.2, the AA2300 supports measurement uncertainty estimation and proficiency testing compliance.
What maintenance routines are recommended for long-term stability?
Daily: Optics purge with dry nitrogen; weekly: HCL alignment verification and graphite tube resistance check; quarterly: PMT gain calibration and burner head cleaning per manufacturer’s technical bulletin TB-AA2300-04.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0