BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelHVG-A
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Region CategoryDomestic (China)
ModelSFJ-16M
PricingUpon Request
Minimum Detectable Leak Rate (ULTRA mode, He)5.0×10⁻¹³ Pa·m³/s
Minimum Detectable Leak Rate (FINE mode, He)1.0×10⁻¹² Pa·m³/s
Minimum Detectable Leak Rate (Sniffer mode)5.0×10⁻⁹ Pa·m³/s
Max. Allowable Test Pressure (ULTRA)40 Pa
Max. Allowable Test Pressure (FINE)200 Pa
Sniffer Mode Max. Pressure1800 Pa
Detection Masses2 (H₂), 3 (³He), 4 (⁴He)
Ion SourceDual iridium-coated yttria emitters with auto-switching
Vacuum InterfaceULTRA: DN25 KF
FINEDN16 KF
SnifferDN25 KF
Human-Machine Interface5-inch color LCD touchscreen
Dimensions (SFJ-16M standalone)400 × 330 × 301 mm
Dimensions (SFJ-16M + turbomolecular pump option)400 × 315 × 310 mm
Power SupplyDC 24 V (±5%)
Response Time<1 s
Pump-down & Startup Time<95 s
Operating Temperature0–40 °C
Display LanguagesEnglish / Chinese
Data VisualizationNumeric value, bar graph, real-time leak rate curve
I/O InterfacesRS-232, RS-485, LAN
MES IntegrationStandard support
ComplianceDesigned for ISO 20484 (leak testing), ASTM E1776, and GLP/GMP-aligned operational logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelWMS1800s
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelLC3200S Series
Instrument TypeConventional HPLC System
Application ScopeGeneral-Purpose Analytical HPLC
Maximum Operating Pressure45 MPa
Wavelength Range (UV/Vis Detector)188–900 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelPA2000
Instrument TypePortable
Detection PrincipleCatalytic Oxidation + Flame Ionization Detection (FID)
Regulatory ComplianceHJ 1012–2018
Detection LimitSub-ppb (NMHC)
Analysis CycleAs low as 5 seconds
Operating TemperatureFull-path high-temperature heating (≥180 °C)
Methane Separation MethodHigh-efficiency catalytic oxidation (≥98% conversion efficiency)
Catalyst Lifetime≥3 years
Oxygen MeasurementIntegrated paramagnetic/O₂ sensor
Weight~13 kg
Carrier GasNot required
Combustion AirBuilt-in compressor — no external air supply needed
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM/ODM)
Country of OriginChina
ModelAQ7100
PricingAvailable upon Request
Measured ParametersSO₂, NO₂, CO, O₃, PM₂.₅, PM₁₀, TVOC, Temperature, Relative Humidity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWayeal
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Model SeriesGC6000
Temperature Control Range+4 °C above ambient to 450 °C
Maximum Ramp Rate60 °C/min
Carrier Gas Flow ControlElectronic Flow Control (EFC)
Injector Maximum Operating Temperature400 °C
Detector OptionsFID6000 (standard), ECD (optional)
Autosampler CompatibilityALS6000 (optional)
Air Purification SystemWayeal-built (optional)
MS Interface预留接口 (MS coupling port available upon request)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelTQ9200
Instrument TypeTriple Quadrupole (Tandem QqQ) Mass Spectrometer
Application ScopeUniversal (Broad-Spectrum Quantitative & Qualitative Analysis)
LC ComponentWAYEAL LC3600 Ultra-High-Performance Liquid Chromatograph
Ionization SourceElectrospray Ionization (ESI), Standard Configuration
Vacuum InterfaceHigh-Durability Conical Interface with Active Desolvation
Detection ModeMultiple Reaction Monitoring (MRM), Selected Reaction Monitoring (SRM), Full Scan, Product Ion Scan, Precursor Ion Scan, Neutral Loss Scan
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelLD1200A
PricingUpon Request
Measurement PrincipleLaser Forward Light Scattering
Safety RatingNon-Explosive
Measurement Range0–15 mg/m³
Resolution0.1 mg/m³
Accuracy±10% of reading
Relative Error±2%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Benchtop Ion Chromatograph
ModelIC6500
Pump Pressure Rating42 MPa
Operating Temperature Range5 °C to 70 °C
Flow Path MaterialFull PEEK
Detector ConfigurationDual Conductivity Detector
Eluent GenerationIntegrated On-Line Electrolytic Eluent Generator
Application ScopeGeneral-Purpose Anion/Cation Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelGC6100
Application ScopeGeneral-Purpose
Control ArchitectureDual-Core Mainboard (Quad-Core Application Processor + Dual-Core Co-Processor)
Temperature ControlPID with Auto-Tuning & Environmental Compensation
EPC SystemHigh-Stability Electronic Pressure Control
Detectors SupportedFID (1000 Hz Sampling Rate, 0.5 ms Minimum Peak Width), ECD (Low-Radiation Microcell), MS (Integrated with WAYEAL Mass Spectrometer)
Software PlatformSmartLab CDS Workstation with H.B.C-ApexFinder & SmartPeak Algorithms
ConnectivityWeb-Based UI, Touchscreen (10.1" Capacitive), Remote Access via Browser
Compliance FeaturesAudit Trail, User Permission Levels, Electronic Signatures (FDA 21 CFR Part 11 Ready), GLP/GMP Data Integrity Support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (PRC)
ModelModular Differential Pressure Airtightness Leak Tester
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelFLD
Instrument TypeFluorescence Detector (FD)
Wavelength Range200–650 nm
Detection ModeFluorescence
Light SourceMercury-Xenon Lamp
Display InterfaceTouchscreen LCD
Data OutputDual Analog Channels
Communication InterfacesRS232, Ethernet
Compatible SystemHigh-Performance Liquid Chromatography (HPLC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOEM Manufacturer
Origin CategoryDomestic (China)
ModelZH600-X Multi-Station Hermeticity Leak Detector
PricingAvailable Upon Request
Pressure Sensor Range (ZH600-X)10–500 kPa (mechanically regulated)
Sensor Accuracy±0.1% FS
Display ResolutionAdjustable to 0–4 decimal places
Pressure UnitskPa, MPa, kg/cm², psi, mbar, bar, Torr, mmH₂O, mmHg
Leak Rate UnitsPa, kPa, Pa/s, kPa/s, kPa/min, mL/s, mL/min, mL/h, L/min, L/h, SCCM
Programmable Test Profiles64 total (16 per channel across A/B/C/D channels)
Test Cycle Time0–999 s (max test duration: 1800 s)
Power SupplyAC 220 V ±10%, 50 Hz
Required Test Gas SourceClean, dry, ≥500 kPa supply pressure, ≥100 kPa above test pressure
Dimensions (ZH600-X)431 × 187 × 460 mm
Weight~14 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelAQ7800
Instrument TypeOnline Fixed-Station Analyzer
Detection PrincipleGas Chromatography with Flame Ionization Detection (GC-FID)
Measurement MethodDirect Analysis (Non-Preconcentration Bypass Mode with Cold Trap Preconcentration Option)
Detection Limit≤1 ppbC (as Carbon)
ComplianceHJC-ZY84-2020
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
ManufacturerWAYEAL Instrument Co., Ltd.
ModelWS1801
Instrument TypeOnline Automatic Water Sampler
Sampling MethodExceedance-triggered Retention Sampling
Single Sample Volume10 mL to 1000 mL
Sampling Volume Accuracy±7% (at 200 mL retention volume)
Sampling IntervalAdjustable from 1 min to 9999 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of ManufactureChina
ModelSFJ-16C / SFJ-16D
Base PumpRotary Vane Vacuum Pump (SFJ-16C) / Scroll Vacuum Pump (SFJ-16D)
Minimum Detectable Leak Rate (Vacuum Mode)5.0 × 10⁻¹³ Pa·m³/s
Minimum Detectable Leak Rate (Sniffer Mode)2.5 × 10⁻⁹ Pa·m³/s
Maximum Allowable Test Pressure1800 Pa
Human-Machine Interface7-inch Color TFT LCD Touchscreen
Leak Port ConnectionDN25 KF
Dimensions (W×D×H)475 × 714 × 1168 mm
Power SupplyAC 220 V (±10%), 50/60 Hz
Response Time<1 s
Pump-Down/Startup Time<95 s
Detectable Massesm/z = 2 (H₂), 3 (³He), 4 (⁴He)
Ion SourceDual Filament, Yttria-Coated Iridium, Auto-Switching
I/O InterfacesRS-232, RS-485, LAN, MES Integration Ready
Operating Temperature0–40 °C
Display LanguagesEnglish & Chinese
Leak Rate VisualizationNumeric Value, Bar Graph, Real-Time Trend Curve
ComplianceDesigned for ISO 10110-7, ASTM E1003, and JIS Z 2301 aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelLC3600 Series
Instrument TypeUltra-High-Performance Liquid Chromatograph (UHPLC)
Application ScopeGeneral-Purpose Analytical Instrumentation
Wavelength Range188–900 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelWMS1800
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelLC3400
Instrument TypeUltra-Fast Liquid Chromatograph
Maximum Operating Pressure75 MPa
Application ScopeGeneral-Purpose HPLC/UHPLC Analysis
ComplianceDesigned for ISO/IEC 17025-compliant laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelVM1700
Instrument TypeOnline Continuous Emission Monitoring System (CEMS)
Detection PrincipleGas Chromatography–Flame Ionization Detection (GC-FID)
Target AnalytesMethane (CH₄), Total Hydrocarbons (THC), Non-Methane Hydrocarbons (NMHC), and selected BTEX compounds
Sample Path Temperature175 °C (fully heated from probe to detector)
ComplianceCertified by China National Environmental Monitoring Centre (CNEMC) for CEMS applicability testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelCEMS 1200
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement Accuracy≤ ±5% FS
Repeatability≤ 1% FS
Response Time≤ 90 s
Drift Stability≤ 1% FS over 7 days
Measured ParametersSO₂, NOₓ (NO + NO₂), O₂, CO, CO₂, HCl, particulate matter (PM) concentration, flue gas velocity, static pressure, relative humidity, emission rate, and cumulative emissions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelWS1504
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelCEMS1250
Instrument TypeFlue Gas Continuous Emission Monitoring System
Measurement Accuracy±2.5% FS
Repeatability±2% FS
Response Time200 s
Long-term Stability±5% FS
Measured ParametersSO₂, NO, O₂, Particulate Matter (PM) Concentration, Flue Gas Temperature, Pressure, Velocity, Relative Humidity
Derived OutputsEmission Rate, Total Emissions
Sampling MethodDirect Extraction with Cold-Dry Conditioning
Certified Low-Range QuantificationSO₂ & NO at 0–45 mg/m³
PM Detection PrincipleLaser Forward Scattering
PM Certified Range0–15 mg/m³
ComplianceMeets Chinese HJ 75–2017 and HJ 76–2017 Technical Specifications for CEMS