Empowering Scientific Discovery

Southland MOMD-525 Trace Oxygen Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Southland
Model MOMD-525
Measurement Principle Electrochemical Fuel Cell (TO2-1x Sensor)
Range Options 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–1% / 0–25% O₂
Accuracy < ±1% FS
Response Time T₉₀ ≤ 10 s
Operating Temperature 0–50 °C
Enclosure Rating IP66 / NEMA 4X
Output Signal 4–20 mA (isolated)
Power Supply 14–28 VDC or 100–240 VAC via included adapter
Display Color backlit LCD
Data Logging USB flash drive (up to 8 GB, supports ~50 years of timestamped data)
Sensor Lifetime 20–25 months
Calibration Manual zero/span via front panel or remote command
Mounting Wall-mounted
Warranty 12 months

Overview

The Southland MOMD-525 Trace Oxygen Analyzer is a wall-mounted, industrial-grade electrochemical analyzer engineered for continuous, high-stability measurement of oxygen concentration across five selectable ranges—from sub-ppm trace levels (0–10 ppm) up to ambient and enriched oxygen environments (0–25% O₂). At its core resides the TO2-1x precision fuel cell sensor, manufactured in Southland’s ISO-certified facility in California and designed using proprietary solid polymer electrolyte technology. Unlike galvanic or zirconia-based sensors, this electrochemical cell operates without liquid electrolyte, eliminating maintenance requirements such as electrode cleaning or electrolyte replenishment. The analyzer employs coulometric detection—measuring current proportional to oxygen partial pressure—delivering inherent linearity, low drift, and long-term baseline stability essential for critical process monitoring where false alarms or undetected excursions pose operational or safety risks.

Key Features

  • Five user-selectable measurement ranges: 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1%, and 0–25% O₂—configured via intuitive front-panel interface.
  • TO2-1x trace oxygen sensor with <20 ppm zero drift per year and <0.5% FS span drift over 12 months—validated under accelerated aging protocols per ASTM D6300.
  • Robust IP66/NEMA 4X-rated enclosure suitable for harsh industrial environments including washdown zones and outdoor installations.
  • Real-time color backlit LCD display with dual-unit readout (e.g., ppm + %), status icons, and diagnostic flags (e.g., low sensor voltage, calibration due).
  • Isolated 4–20 mA analog output with HART-compatible digital overlay for integration into DCS/PLC systems; configurable for linear or square-root scaling.
  • Onboard data logging via standard USB flash drive—supports automatic timestamped storage of O₂ readings, sensor diagnostics, and alarm events at user-defined intervals (1 sec to 24 hr).

Sample Compatibility & Compliance

The MOMD-525 is optimized for dry, non-corrosive gas streams with dew point ≤ –20 °C and particulate content < 1 µm. It is compatible with nitrogen, argon, helium, CO₂, hydrogen, and synthetic air matrices—commonly deployed in inert atmosphere control loops. The instrument meets UL 61010-1 (3rd Ed.) for electrical safety and complies with EMC Directive 2014/30/EU (EN 61326-1). Its design supports adherence to Good Manufacturing Practice (GMP) and FDA 21 CFR Part 11 requirements when paired with validated data management workflows—including audit-trail-enabled calibration logs and immutable USB-recorded datasets.

Software & Data Management

While the MOMD-525 operates autonomously without PC dependency, its USB data logging architecture enables seamless post-acquisition analysis using standard spreadsheet or SCADA historian tools. Each logged file includes ISO 8601 timestamps, sensor health metrics (e.g., internal temperature, cell voltage), and configurable metadata fields. For enterprise integration, optional Modbus RTU (RS-485) firmware upgrade provides bidirectional communication—supporting remote zero/span calibration, range switching, and firmware updates. All configuration changes are stored in non-volatile memory with write-cycle logging for GLP/GMP traceability.

Applications

  • Inert glovebox atmospheres (e.g., battery R&D, semiconductor handling) requiring sustained O₂ < 1 ppm.
  • Pressure Swing Adsorption (PSA) nitrogen generators—monitoring breakthrough oxygen to optimize cycle timing and carbon molecular sieve life.
  • Beverage-grade CO₂ purity verification per ISO 22000 and Annex A of EC No. 178/2002—ensuring O₂ ≤ 10 ppm before carbonation.
  • Air separation plant (ASP) product stream validation, especially for high-purity nitrogen used in pharmaceutical blanketing.
  • Control of purge gas quality in heat-treating furnaces and laser cutting assist gas lines.

FAQ

What calibration gases are recommended for the MOMD-525?

Zero gas: High-purity nitrogen (99.999%+, O₂ < 10 ppb); Span gas: Certified O₂-in-N₂ standard matching the selected range (e.g., 5 ppm O₂ for trace mode).
Can the TO2-1x sensor be replaced in the field?

Yes—the sensor module is user-replaceable without tools; full replacement takes < 90 seconds and requires no recalibration if using factory-preconditioned units.
Does the analyzer support automatic temperature compensation?

Yes—integrated Pt1000 RTD measures sample gas temperature at the sensor inlet and applies real-time correction per NIST SRM 2621 algorithms.
Is the USB data log format compatible with LIMS systems?

Data exports as comma-separated values (CSV) with UTF-8 encoding and ISO 8601 timestamps—directly ingestible by LabWare, STARLIMS, and Thermo Fisher SampleManager.
What is the minimum sample flow rate required?

100–500 mL/min; flow-controlled via integrated needle valve or external mass flow controller—no pressure regulation needed below 15 psig.

InstrumentHive