| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | M8880 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Carrier Gas Options | Single selectable gas (e.g., He, H₂, or Ar) |
| Dual-Detector Configuration | PDHID + TCD |
| Independent Temperature Zones | 8 |
| Oven Programmed Ramps | 20-step |
| Back-Flush & Heart-Cut Capability | Integrated |
| Detection Limits (v/v) | PDHID — H₂: 0.06 µL/L, CH₄: 0.08 µL/L, CO: 0.08 µL/L, C₂H₆: 0.01 µL/L, CO₂: 0.09 µL/L, C₂H₄: 0.01 µL/L, C₂H₂: 0.01 µL/L, C₃H₈: 0.01 µL/L, H₂S: 0.01 µL/L, C₃H₆: 0.01 µL/L, SO₂: 0.23 µL/L |
| TCD — O₂ | 49 µL/L, N₂: 70 µL/L |
| PDHID Specifications | Pulsed Discharge Helium Ionization Detector |
| TCD Specifications | Baseline Noise ≤ 20 µV |
| Brand | Southland |
|---|---|
| Origin | USA |
| Model | MOMD480, MOMD525 |
| Measurement Principle | Electrochemical (Galvanic Cell) |
| Range Options | 0–1%/5%/10%/25%/100% (MOMD480) |
| Accuracy | ±1% FS |
| Display | Backlit Color LCD |
| Enclosure Rating | IP66 / NEMA 4X |
| Output | Dual Adjustable Relay Alarms (MOMD525) |
| Operating Environment | Inert, N₂, H₂, CO₂-containing, or mixed gas matrices |
| Compliance | CE, Class I, Div. 1, Groups B, C, D (MOMD625 variant) |
| Brand | Southland |
|---|---|
| Origin | USA |
| Model | 525X |
| Measurement Range | 0–10 / 100 / 1000 ppm, 0–1% / 5% / 10% / 25% / 100% O₂ |
| Accuracy | < ±1% FS |
| Display | Backlit LCD |
| Enclosure | Die-cast aluminum, IP66 / NEMA 4X rated |
| Mounting | Wall-mountable |
| Operating Temperature | 0–50 °C |
| Power Supply | 10–28 VDC or 100–240 VAC |
| Output Signals | 4–20 mA (standard), 1–5 VDC (optional) |
| Data Logging | USB flash drive (up to 8 GB), configurable interval 1–120 min |
| Alarm Outputs | Two non-latching relay contacts |
| Flow Rate Sensitivity | 0.5–5 SCFH |
| Pressure Range | 0.1–50 PSIG |
| Warranty | 12 months (sensor & electronics) |
| Compliance | CE-marked, RoHS-compliant, designed for GLP/GMP-aligned environments |
| Brand | Sabio |
|---|---|
| Origin | Beijing, China |
| Model | 1001 |
| Output Pressure | 25 psi |
| Standard Flow Rate | 22 L/min (SLP) |
| Condensate Tank Capacity | 3.4 L |
| Air Purity | NO/NO₂/O₃/H₂S/SO₂ < 0.5 ppb, CO < 25 ppb, HC < 200 ppb |
| Dew Point | ≤ −20 °C at 15 L/min |
| Dimensions | 222 mm (H) × 412 mm (W) × 565 mm (D) |
| Power Supply | 220 VAC, 50 Hz |
| Compressor Type | Brushless, Oil-Free |
| Condensate Drain | Automatic or Manual |
| Optional | Built-in CO oxidation catalyst, HC oxidation catalyst, pressure switch, flow meter, rack-mount kit, LED dew point display |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TU-1810 |
| Quotation | Upon Request |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Wavelength Repeatability | 0.2 nm |
| Spectral Bandwidth | Fixed 2 nm |
| Stray Light | <0.3%T (220 nm, NaI |
| Photometric Modes | Transmittance (%T), Absorbance (Abs), Energy |
| Photometric Range | −0.3 to 3.0 Abs |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs) |
| Photometric Repeatability | 0.001 Abs (0–0.5 Abs) |
| Baseline Flatness | ±0.002 Abs (190–1100 nm) |
| Baseline Drift | 0.001 Abs/h (500 nm, 0 Abs, after 2 h warm-up) |
| Photometric Noise | ±0.001 Abs (500 nm, 0 Abs, 2 nm SBW) |
| Key | Brand: Restek |
|---|---|
| Origin | USA |
| Material | Electropolished Stainless Steel (316L) |
| Valve Type | Parker Hannifin Metal-to-Metal Sealed Diaphragm Valve (2/3-turn) |
| Volume Options | 1 L, 3 L, 6 L, 15 L |
| Operating Temperature | Up to 250 °C |
| Internal Surface Treatment | Electropolishing + Ultrasonic Cleaning + Passivation |
| Leak Integrity | Helium-leak tested (<1×10⁻⁹ atm·mL/s) |
| Pressure Rating | 60 psig / Vacuum Range: –30" Hg |
| Compliance | EPA TO-14A, TO-15A, ASTM D5466, USP <661> |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | FID Gas Station |
| Hydrogen Flow Rate | 100–1000 mL/min |
| Hydrogen Purity | 99.9996% or 99.99996% |
| Hydrogen Output Pressure | up to 11 barg (160 psig) |
| Zero Air Flow Rate | 1.8–5 L/min |
| Zero Air Hydrocarbon Content | < 0.1 ppm |
| Configuration Options | Horizontal (GC-under bench) or Vertical (space-saving rack-mount) |
| Rack Compatibility | 19-inch standard enclosure (Hydrogen 19” Rack Plus variant) |
| Compliance | Designed for continuous operation in GLP/GMP and ISO/IEC 17025-accredited laboratories |
| Brand | Southland Sensing |
|---|---|
| Model | MOMD-480 |
| Origin | USA (California) |
| Measurement Principle | Electrochemical Fuel Cell |
| Range Options | 0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (selectable) |
| Accuracy | < ±1% FS |
| Response Time | ≤10 s to T90 |
| Operating Temperature | 0–50 °C |
| Gas Pressure Range | 0–50 PSI (inlet) |
| Power | Rechargeable Li-ion battery + 100–240 VAC adapter |
| Dimensions | 8.80 × 7.50 × 3.90 in (223.5 × 190.5 × 99.1 mm) |
| Weight | 4.8 lb (2.18 kg) |
| Enclosure Material | Polypropylene |
| Sensor Lifetime | 60 months |
| Analog Output | 0–1 VDC |
| Data Logging | USB flash drive (up to 8 GB, supports >50 years of timestamped data at 1-min intervals) |
| Display | Backlit high-contrast LCD |
| Warranty | 12 months |
| Compliance | Designed for GLP-compliant field use |
| Brand | MNK |
|---|---|
| Origin | Sweden |
| Model | BIOTECH Series Vacuum Degasser |
| Internal Volume | 480 µL per Channel |
| Max. Channel Pressure | 70 PSI |
| Wetted Materials | Systec AF™ Membrane, PEEK, Glass-Filled PTFE |
| Dimensions (L×H×W) | 245 × 111 × 59 mm |
| Power Supply | 110–240 V, 50/60 Hz |
| Operating Mode | Continuous 7×24 |
| Design Life | ≥5 Years Fault-Free Operation |
| Vacuum Control | Closed-Loop with ZHCR® Stepper Motor Drive |
| Leak & Error Pre-Diagnosis | Yes |
| Channel Options | 1–6 Channels |
| Chemical & Biological Compatibility | Fully Validated for HPLC Mobile Phases and Biopharmaceutical Buffers |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | SWH4, HKS, VSH, FRK1 |
| Unit Price | USD 1.00 |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MY702-4/6 |
| Maximum Flash Vaporization Temperature | 230 °C |
| Heating & Jacket Temperature Range | Ambient +5 °C to 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Ports | 4 or 6 positions + 1 purge gas channel |
| Inlet Fitting | M14×1.5 internal thread quick-connect |
| Tubing | 1/16″ SilcoTek-passivated stainless steel |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 100 W |
| Dimensions (4-port) | 400 × 255 × 300 mm |
| Net Weight | 20 kg |
| Compliance | Designed for ASTM D6667, ASTM D7164, ISO 8570, and USP <621> gas chromatographic workflows requiring trace sulfur and oxygenate analysis |
| Brand | MNK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VOC |
| Pricing | Available Upon Request |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | VICI TGA |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Detection Limit | Sub-ppb (parts-per-quadrillion achievable with optimized configuration) |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories, supports FDA 21 CFR Part 11 audit trails (with optional software package), GLP/GMP-ready architecture |
| Output Options | Configurable digital (RS-485, Ethernet/IP, Modbus TCP) and analog (4–20 mA, 0–10 V) outputs |
| Sample Interface | Valco®-sourced high-integrity pneumatic valves, Sulfinert®/Silcosteel®-passivated flow paths, electropolished stainless-steel manifolds |
| Calibration | Automated on-board calibration with user-defined schedules, NIST-traceable standard gas integration |
| Data Handling | OPC UA server integration, automated daily maintenance logging, CSV/Excel export via embedded web interface |
| Form Factor | Rack-mountable (19″ 4U chassis) or standalone industrial enclosure (NEMA 4X rated) |
| Support | Lifetime remote diagnostics and application engineering support included |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | Valco HP2 |
| Gas Compatibility | He, Ar, Ne, Kr, Xe, Rn |
| Max Operating Pressure | 1000 psi |
| Impurity Removal Limit | <10 ppb (H₂O, H₂, O₂, N₂, CO, NO, NH₃, CO₂) |
| Excluded Gases | He, Ar, Ne, Kr, Xe, Rn (i.e., does not remove carrier gas itself) |
| Heating Control | Integrated thermal regulation system |
| Certification | CE compliant |
| Power Options | 110 VAC or 230 VAC |
| Replacement Cartridge Part No. | MNK283165 (He) |
| Mounting | In-line upstream of GC inlet |
| Brand | Southland |
|---|---|
| Origin | USA |
| Model | H2S-150-NG |
| Measurement Principle | Electrochemical Fuel Cell Sensor |
| Range Options | 0–200 ppm (H2S-1X) or 0–2000 ppm (H2S-2X) |
| Accuracy | < ±2% of Full Scale |
| Response Time (T90) | 60 s |
| Operating Temperature | 0–50 °C |
| Sample Flow Rate | 0.5–2.0 SCFH |
| Inlet Pressure Range | 0.1–50 PSI |
| Output Signal | 4–20 mA or 1–5 VDC |
| Enclosure Rating | Class 1, Div 2, Groups C & D |
| Dimensions | 11.25 × 12.0 × 5.50 in |
| Weight | 12.5 lbs |
| Sensor Lifetime | 12 months |
| Calibration Interval | Every 1–3 months with certified span gas |
| Gas Connection | 1/4" compression fitting |
| Electrical Isolation | Galvanically isolated power and analog outputs |
| Optional | Dual-loop configuration, RS-485 Modbus RTU interface |
| Brand | Sabio |
|---|---|
| Origin | Beijing, China |
| Model | 2020 |
| Flow Rate | 10 SLPM at 20 psig |
| Purification Targets | NO, NO₂, O₃, SO₂, H₂S < 0.5 ppb (standard) |
| Dew Point | < –40 °C (via integrated permeation dryer) |
| Power Supply | 196–264 VAC, 50–60 Hz |
| Analog Output | 4–20 mA (max. load 750 Ω) |
| Dimensions | 165 mm (H) × 353 mm (W) × 381 mm (D) |
| Weight | 10.4 kg |
| Compliance | Designed for ISO 8573-1 Class 1 compressed air purity |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8810 |
| Instrument Type | Online Gas Chromatograph |
| Application Focus | High-Purity Gas Analysis |
| Detector Configuration | Up to 3 Simultaneous Detectors (PDHID, TCD, FID, FPD) |
| Communication Interface | Ethernet-enabled Industrial Bus Architecture |
| Compliance Context | Designed for GLP/GMP-aligned environments with audit-ready data handling capabilities |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HP Plus Tower |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 0.5–4 L/min |
| Output Pressure | 5 bar (75 psig) |
| Nitrogen Purity | 99.999% (≤10 ppm O₂, ≤0.1 ppm total hydrocarbons with optional HC module) |
| Dew Point | −50 °C |
| Inlet Air Pressure | 7–10 bar (100–160 psi) |
| Interface | LED display with power switch, system status, and error indicators |
| Connection | Inlet – 1/4" NPT, Outlet – 1/8" NPT |
| Noise Level | Low (external air compressor design) |
| Brand | Sabio |
|---|---|
| Origin | Beijing, China |
| Model | 4010L |
| Diluent Flow Range | 0–10 SLM (optional up to 20 SLM) |
| Source Gas Flow Range | 0–100 SCCM / 0–10,000 SCCM |
| Flow Accuracy | ≤ ±1% FS |
| Flow Repeatability | ≤ ±0.15% FS |
| Linearity | ≤ ±0.5% FS |
| Inlet Pressure | 20–35 PSIG |
| Ozone Generator Output | 0.05–1.5 ppm at 5 SLPM |
| Ozone Generator Accuracy | ±1% of setpoint or ±2 ppb at 5 SLPM |
| UV Absorption Photometer Range | 0–0.5 / 1.0 / 2.0 ppm |
| Photometer Zero Drift | < ±1 ppb per 24 h (or 30 days) |
| Photometer Flow Rate | 1.0 LPM |
| Dilution Furnace Temperature Range | Ambient +5 °C to 65 °C |
| Temperature Stability | < ±0.1 °C |
| Calibration Programs | 20 user-configurable, time- and event-driven (7-day cycle support) |
| Input/Output | 24-bit digital I/O, 2× serial ports (RS232 standard), parallel printer port, external keyboard interface, air source control port |
| Display | High-brightness color LCD |
| Keypad | 55-key membrane panel |
| Gas Ports | 4 source gas inlets, 1 purge inlet, 1 diluent inlet, 5 calibrated outputs, 1 exhaust port |
| Brand | Southland |
|---|---|
| Origin | USA |
| Model | H2S-625 |
| Linear Error | < ±1% FS |
| Repeatability | < ±1% FS |
| Span Drift | < ±1% FS |
| Response Time (T90) | 45 s |
| Explosion Protection Rating | Class I, Division 1, Group B, C, D |
| Brand | MNK |
|---|---|
| Model | MQY301 |
| Origin | Beijing, China |
| Configuration | 5-channel gas bag sampler + 1-channel liquid flash-vaporization inlet |
| Dimensions (W×D×H) | 400 × 255 × 300 mm |
| Net Weight | 15 kg |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 300 W |
| Maximum Flash-Vaporization & Jacket Temperature | 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Liquid Injection Pressure Range | 100–400 psi |
| Sample Transfer Line | Passivated stainless steel |
| Interface Options | AUX trigger, touch control, GC instrument control port |
| Inlet Valve | Integrated 6-position gas sampling valve with quantitative loop |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Technology | Proton Exchange Membrane (PEM) Electrolysis |
| Hydrogen Purity | ≥99.99999% |
| Oxygen Impurity | ≤0.01 ppm |
| Moisture Content | ≤1.0 ppm |
| Output Pressure Options | 100 psig or 175 psig |
| Flow Rate Options | 510–1300 cc/min |
| Outlet Port | 1/4" NPT |
| Power Input | 100–230 VAC, 50/60 Hz |
| Dimensions | 17.1" H × 13.5" W × 21" D |
| Weight | 60 lbs |
| Palladium-Alloy Membrane Lifetime | 3-year warranty |
| System Warranty | 1 year |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | MG220 |
| Pricing | Upon Request |
| Operating Pressure Range | 0.7–4 MPa |
| Drive Gas | Dry Air or Inert Gas (0.4 MPa) |
| Auxiliary Gas Flow Rate | 50–200 mL/min |
| Internal Tubing | 1/16″ SilcoTek-Passivated Stainless Steel |
| Valve Core Volume Options | 0.06–2 μL (Standard: 1 μL) |
| Dead Volume | Minimized (<10 μL typical) |
| Repeatability | RSD < 2% (n ≥ 6) |
| Dimensions (W×D×H) | 130 mm × 200 mm × 200 mm |
| Mounting | Direct installation above GC inlet port |
| Weight | ~1.5 kg |
| Surface Treatment | SilcoTek® SilcoNert® 2000 inert coating applied to entire fluid path |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor & System Integrator |
| Regional Classification | Domestic (China-Made) |
| Model | GC7890B |
| Pricing | Upon Request |