SRI 110/310/410/8610C-D Series Gas Chromatograph

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand SRI
Origin USA
Model Variants 110, 310, 410, 8610C, 8610D
Configuration Benchtop or Portable Chassis Options
Detectors FID, TCD, SCD, PID (User-Selectable)
Compliance ASTM D1945, D1946, D3588, ISO 8573-5, USP <467>, EPA Method TO-14A/TO-15
Data System Standalone PC-Based Acquisition & Processing Software (No Dedicated Terminal Required)

Overview

The SRI 110/310/410/8610C-D Series Gas Chromatograph is a modular, field-deployable analytical platform engineered for precision separation and quantification of volatile and semi-volatile organic compounds (VOCs), permanent gases, hydrocarbons, sulfur species, and greenhouse gases. Based on robust packed and capillary column gas chromatography principles, the system employs temperature-programmed oven control, precise carrier gas flow regulation (via electronic pressure control or mechanical flow controllers), and detector-specific signal conditioning to deliver high reproducibility across diverse sample matrices. Designed for both laboratory and mobile deployment—including on-site environmental monitoring, transformer maintenance, petrochemical process support, and academic teaching—the instrument supports rapid reconfiguration between applications without hardware modification. Its architecture conforms to fundamental GC performance criteria defined in ASTM E1618, ISO 17025-compliant operation environments, and method validation frameworks required under GLP and regulated QC workflows.

Key Features

  • Modular chassis design: Select from four standardized platforms—110 (compact benchtop), 310 (enhanced thermal stability), 410 (dual-detector capability), and 8610C/D (high-sensitivity dual-column systems with backflush)—each supporting interchangeable detector modules and column configurations.
  • Field-ready portability: Integrated power conditioning, shock-absorbing chassis mounts, and optional battery-backed operation enable stable GC performance during transport and at remote locations—including substation sites, offshore platforms, and soil vapor extraction points.
  • Detector flexibility: Compatible with flame ionization (FID), thermal conductivity (TCD), sulfur chemiluminescence (SCD), photoionization (PID), and electron capture (ECD) detectors—configured per application requirements without external signal amplifiers.
  • Column system versatility: Supports both packed and fused-silica capillary columns (up to 60 m), including narrow-bore (0.1–0.25 mm ID) and wide-bore formats; dual-column setups allow simultaneous analysis using complementary selectivity (e.g., PLOT Al₂O₃/KCl + DB-1).
  • Self-contained data acquisition: Embedded analog-to-digital conversion and real-time peak integration run on standard Windows-based PCs via USB or Ethernet; no proprietary terminal hardware or operating system dependencies.
  • Method portability: GC methods—including oven ramp profiles, valve events, detector parameters, and calibration tables—are stored as portable XML files, enabling seamless transfer between instruments and laboratories.

Sample Compatibility & Compliance

The SRI GC series accommodates gaseous, liquid, and dissolved-phase samples through standardized inlet interfaces: split/splitless injectors, gas-tight syringes, purge-and-trap concentrators, headspace autosamplers, and direct gas loop valves. It meets documented performance criteria for regulated analyses including ASTM D1945 (natural gas), D3588 (LNG), ISO 8573-5 (compressed air purity), USP (residual solvents), and EPA Methods TO-14A (ambient air VOCs) and TO-15 (canister-based VOCs). For transformer oil DGA, the system complies with IEC 60567 sampling protocols and enables full C1–C3 hydrocarbon speciation (H₂, CH₄, C₂H₆, C₂H₄, C₂H₂, CO, CO₂) with sub-ppm detection limits when paired with TCD/FID dual detection. All firmware and software versions maintain audit trails compliant with FDA 21 CFR Part 11 for electronic records and signatures where enabled.

Software & Data Management

ChromPerfect® GC control and analysis software (v3.5+) provides method development tools, automated calibration curve generation (linear, quadratic, multi-level), peak deconvolution for co-eluting analytes, and customizable reporting templates aligned with ISO/IEC 17025 documentation standards. Raw data files (.cpd) are stored in open binary format with embedded metadata (instrument ID, operator, date/time, method version, detector settings). The software supports LIMS integration via ASTM E1394-compliant file export and includes built-in validation packages for IQ/OQ/PQ execution. Data integrity safeguards include user role-based access control, electronic signature capture, and immutable audit logs tracking all method edits, calibration updates, and result modifications.

Applications

  • Transformer oil dissolved gas analysis (DGA) per IEEE C57.104 and IEC 60599
  • Greenhouse gas monitoring (CO₂, CH₄, N₂O) in ambient air, flue gas, and biogas streams
  • Trace sulfur compound detection (H₂S, COS, mercaptans) in natural gas and refinery streams
  • BTEX and aromatic hydrocarbon quantification in soil vapor, groundwater, and indoor air
  • BTU value calculation for pipeline gas via compositional analysis (N₂, CH₄, C₂H₆, C₃H₈, i-C₄H₁₀, n-C₄H₁₀, C₅+)
  • Explosives residue screening (TNT, RDX, HMX) in security and forensic labs
  • PCB congener profiling (Aroclor mixtures) using chlorinated biphenyl-selective columns
  • High-reactivity VOC analysis (C₂–C₆ alkenes/alkanes) in flare stack emissions and combustion off-gas
  • Geoprobe®-compatible soil gas surveys targeting total VOC, chlorinated VOC, and aromatic fractions
  • Academic instruction: Gas cylinder-free training mode with simulated carrier gas and reference standards for undergraduate chromatography labs

FAQ

What column configurations are supported for C40+ hydrocarbon analysis?
Capillary columns such as DB-5ht (30 m × 0.25 mm × 0.1 µm) or equivalent high-temperature stationary phases are recommended; temperature programming up to 400 °C enables elution of heavy n-alkanes and polyaromatics.
Can the system perform simultaneous FID and TCD detection?
Yes—the 410 and 8610C/D models support dual-detector operation with independent signal processing and real-time co-integration.
Is method validation documentation available for regulated use?
SRI provides IQ/OQ protocols, detector linearity reports, retention time repeatability data, and system suitability test (SST) checklists aligned with USP and EP 2.2.46.
How is data integrity maintained during field deployment?
All acquisitions include embedded timestamps, instrument configuration hashes, and digital signatures; local data storage uses write-once media options to prevent post-acquisition alteration.
Does the system support EPA Compendium Method TO-15?
Yes—when configured with a cryogenic trap, stainless steel-lined sample loops, and appropriate capillary columns (e.g., DB-VRX), it meets TO-15 sensitivity and speciation requirements for 97 target VOCs.