SRI
Filter
Showing all 7 results
| Brand | SRI |
|---|---|
| Origin | USA |
| Model Variants | 110, 310, 410, 8610C, 8610D |
| Configuration | Benchtop or Portable Chassis Options |
| Detectors | FID, TCD, SCD, PID (User-Selectable) |
| Compliance | ASTM D1945, D1946, D3588, ISO 8573-5, USP <467>, EPA Method TO-14A/TO-15 |
| Data System | Standalone PC-Based Acquisition & Processing Software (No Dedicated Terminal Required) |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | 8610 |
| Detection Limit | 1 ppb |
| Dimensions | 49.5(W) × 36.8(D) × 34.3(H) cm |
| Regulatory Compliance | EPA Methods 8010, 8015, 8021 |
| Carrier Gas Control | Electronic Pressure Control (EPC), 0–80 psi programmable at 90 psi/min |
| Column Oven | Ambient to 400 °C, 0.01 °C resolution, ±0.1 °C stability, 19.8 × 19.0 × 7.6 cm internal volume |
| Detector Options | 16 configurable detectors, up to 6 simultaneously installed |
| Injection Modes | 12 selectable methods, up to 5 concurrently configured |
| Software | PeakSimple v4.x, USB interface, 4-channel data acquisition |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | SRI-8610C |
| Instrument Type | Portable Gas Chromatograph |
| Temperature Control Range | 0–400 °C |
| Temperature Ramp Rate | 0.1 °C/min (programmable) |
| Cool-down Time | ~15 min (400 °C to ambient) |
| Carrier Gas Flow Control | Electronically adjustable |
| Carrier Gas Pressure Control | 0–80 psi (EPC-programmable) |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–80 psi (programmable) |
| Injector Total Flow Setpoint Range | Adjustable |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | 8610C (Pesticide Residue Configuration) |
| Instrument Type | Portable Gas Chromatograph |
| Temperature Control Range | 0–400 °C |
| Temperature Ramp Rate | 0.1 °C/min (minimum programmable increment) |
| Cooling Time | ~15 min (from 400 °C to ambient) |
| Carrier Gas Flow Range | Adjustable (EPC-controlled) |
| Carrier Gas Pressure Range | 0–80 psi (programmable EPC) |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–80 psi (programmed) |
| Injector Total Flow Setpoint Range | Adjustable |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | 8610C (Routine Configuration) |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Oven Temperature Range | 0–400 °C |
| Temperature Ramp Rate | 0.1 °C/min (minimum programmable increment) |
| Cool-down Time | ~15 min (from 400 °C to ambient) |
| Carrier Gas Flow Control | Electronically adjustable |
| Carrier Gas Pressure Range & Control | 0–80 psi, program-controlled via EPC |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–80 psi, fully programmable |
| Injector Total Flow Setpoint Range | Electronically adjustable |
| Brand | SRI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SRI |
| Price Range | USD 14,000 – 42,000 |
| Brand | SRI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TO-14 Special GC |
| Pricing | Available Upon Request |