Empowering Scientific Discovery

ONUEE UYI-U30 Portable Micro-Flow Gas Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand ONUEE
Origin Guangdong, China
Manufacturer Type Authorized Distributor
Country of Origin China
Model UYI-U30
Linear Error < ±1% FS
Repeatability ±0.2% (zero), ±1% (span)
Response Time 6–25 s (dependent on sensor type, flow rate, tubing length, and digital filtering settings)
Measurement Principles NDIR (CH₄, CO₂), Electrochemical (O₂)
Detection Limits <1% FS
Operating Temperature 0–50 °C
Humidity Range 0–95% RH (non-condensing)
Pressure Compensation ±0.2% FS/10 mbar (800–1200 mbar range)
Power Supply DC 24 V (optional internal Li-ion battery, 8 h runtime)
Dimensions (PCB module) 270 × 220 × 120 mm
Weight 0.8–2.0 kg
Tubing ID 4–6 mm

Overview

The ONUEE UYI-U30 Portable Micro-Flow Gas Analyzer is an engineered solution for real-time, low-volume gas concentration measurement in constrained or transient sampling environments. Designed around high-stability German-sourced NDIR and electrochemical sensing modules, the UYI-U30 operates on fundamental physical principles: non-dispersive infrared absorption for CH₄ and CO₂ detection, and potentiometric electrochemical reaction kinetics for O₂ quantification. Its architecture supports continuous monitoring at volumetric flow rates as low as 15 mL per analysis cycle — a critical capability for applications where sample availability is limited, such as micro-reactor effluent streams, breath analysis prototypes, soil gas flux studies, or lab-scale fermentation headspace characterization. Unlike conventional online analyzers requiring >1 L/min flow or pressurized supply, the UYI-U30 integrates a precision diaphragm vacuum pump and optimized internal fluidics to achieve stable baseline operation under sub-atmospheric (negative-pressure) conditions. This eliminates the need for external sample conditioning systems in many field-deployable use cases.

Key Features

  • Multi-gas capability: Simultaneous or configurable single-gas measurement of CH₄ (0–1%, 0–5%, 0–100% vol), CO₂ (0–5%, 0–50%, 0–100% vol), and O₂ (0–21% vol)
  • Micro-flow optimized design: Minimum required sample volume of 15 mL per measurement; total system dead volume < 8 mL
  • Fast response profile: T₉₀ ≤ 10 s typical for CH₄/CO₂ (NDIR); ≤ 25 s for O₂ (electrochemical), adjustable via digital time constant settings
  • Integrated sample handling: Built-in diaphragm pump with programmable suction pressure control and dual-stage filtration (particulate + hydrophobic membrane)
  • Environmental robustness: Operates continuously from 0–50 °C ambient; humidity tolerance up to 95% RH non-condensing; pressure compensation active across 800–1200 mbar
  • Power flexibility: DC 24 V input standard; optional rechargeable Li-ion battery pack enables 8-hour unattended mobile operation
  • Calibration simplicity: Two-point (zero/span) calibration supported via front-panel interface or PC software; no proprietary tools or gases required

Sample Compatibility & Compliance

The UYI-U30 is compatible with dry or moderately humid gas matrices containing CH₄, CO₂, O₂, and select hydrocarbons (CnHm). It is not intended for corrosive, solvent-saturated, or particulate-laden streams without upstream conditioning. The integrated hydrophobic filter cartridge (standard) prevents liquid water ingress and particulate accumulation on optical windows or electrode surfaces. While not certified to ATEX or IECEx, the unit meets CE marking requirements for electromagnetic compatibility (EN 61326-1) and low-voltage safety (EN 61010-1). Its measurement stability (<±1% FS over 12 months) and linearity (<±1% FS) align with routine QC/QA protocols referenced in ISO 14644-3 (cleanroom air monitoring), ASTM D1945 (natural gas analysis), and USP (analytical instrument qualification). For regulated environments, audit-trail-capable calibration logs and user-accessible firmware versioning support GLP/GMP documentation workflows.

Software & Data Management

The UYI-U30 communicates via RS-232 or USB-C (virtual COM port) using ASCII-based command protocol. ONUEE provides Windows-compatible configuration software for parameter setup (flow rate, averaging time, alarm thresholds), real-time data logging (CSV export), and calibration history management. All measurements include timestamping, sensor status flags (e.g., “filter clogged”, “low battery”), and raw ADC values alongside compensated concentration outputs. Data integrity is preserved through cyclic redundancy check (CRC) on serial frames. The device stores up to 10,000 timestamped records internally when external logging is unavailable. Firmware updates are performed via signed binary upload to ensure traceability and prevent unauthorized modification — a functional prerequisite for FDA 21 CFR Part 11 compliance in validated laboratory settings.

Applications

  • Biogas process monitoring in small-scale digesters and landfill well-head sampling
  • In-line concentration tracking in microfluidic reactors and catalytic screening platforms
  • Soil respiration studies requiring minimal disturbance and low sample draw
  • Medical device prototyping involving exhaled breath metabolite profiling (CH₄, CO₂, O₂)
  • Quality assurance in modified atmosphere packaging (MAP) line validation
  • Educational labs for teaching gas sensor physics, signal processing, and environmental monitoring principles

FAQ

What gases can the UYI-U30 measure simultaneously?
The analyzer supports sequential or dedicated single-gas measurement of CH₄, CO₂, and O₂. Simultaneous multi-gas operation is not enabled by default but can be implemented via time-multiplexed sampling with external valve sequencing.
Is pressure compensation mandatory for accurate readings?
Pressure compensation is recommended when operating outside 950–1050 mbar. Without compensation, span drift may reach ±1% FS per 10 mbar deviation — acceptable for indoor lab use but insufficient for altitude-variable field deployments.
Can the UYI-U30 be integrated into a PLC-controlled process system?
Yes. Analog 4–20 mA outputs (optional) and Modbus RTU over RS-485 (via adapter) are available for industrial automation integration. Digital I/O pins support external trigger and alarm signaling.
How often does the internal filter require replacement?
Under typical clean-air conditions, the hydrophobic filter lasts ≥6 months. In high-humidity or dusty environments, inspection every 4 weeks is advised; replacement kits are field-serviceable without tools.
Does the device support zero-point auto-calibration?
No. Zero calibration requires exposure to certified zero gas (e.g., N₂ for CH₄/CO₂, N₂-balanced for O₂). However, the onboard zero-stabilization algorithm minimizes drift between calibrations.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0