- All
- Favorite
- Popular
- Most rated
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UIC-4 |
| Construction | Copper alcohol cups (4 pcs) |
| Test Angle | 45° sample support fixture (1 set) |
| Brand | MEI / Marlin Engineering |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME1500-3 + ME2100-1 |
| Pricing | Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | CTA |
| Air Flow Range | 0–3 L/min (digital display, adjustable in 0.1 L/min increments) |
| Temperature Control | Dual-mode PID (programmable ramping and single-point setpoint) |
| Max Furnace Temperature | 1100 °C with over-temperature cutoff |
| Furnace Type | Openable tubular furnace with imported thermocouple-equipped quartz heating tube |
| Auxiliary Instruments | Magnetic stirrer, pH meter, conductivity meter |
| Air Filtration | Activated carbon + silica gel columns |
| Compliance | GB/T 17650.1–2–1998, IEC 60754-1/2–1994, EN 50305, BS 6853 Annex B |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WFT |
| Pricing | Available Upon Request |
| Compliance | GB/T 29416–2012 |
| Heat Release Rate Peak | (3.0 ± 0.5) MW |
| Total Energy Release (30 min) | ~4500 MJ |
| Fuel Load | ~400 kg Wood |
| Ignition Delay Alert | Automated 5-min pre-ignition warning |
| Data Acquisition | Real-time temperature, droplet onset, collapse timing, thermal flux, and flame dynamics |
| Sensor Suite | 3 × Medtherm water-cooled heat flux gauges (0–100 kW/m²), 1 × OMEGA anemometer (0–10 m/s, ±0.1 m/s), 30 × OMEGA thermocouples, dual high-resolution CCTV monitoring, Advantech DAQ modules, dedicated control & signal conditioning cabinets |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | TAI |
| Pricing | Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MMS |
| Pricing | Available Upon Request |
| Standards Compliance | EN 348, ISO 9150, GB 8965.2–2009, GB/T 17599–1998 |
| Power Supply | 220 V AC, 50 Hz |
| Operating Environment | 20 ± 2 °C, 65 ± 5 % RH |
| Dimensions (W × H × D) | 800 × 1200 × 450 mm |
| Gas Supply | Oxygen and Acetylene |
| Burner Nozzle Diameter | 1.2 ± 0.1 mm |
| Specimen Pre-tension | 175 ± 0.5 g (via calibrated copper weight) |
| Droplet Guidance Angle | 45° with high-temperature anti-adhesion coated channel |
| Metal Feed Mechanism | Stepper motor–driven wire feed system with adjustable linear speed |
| Backside Temperature Sensor | Calibrated thermocouple array for real-time fabric rear-surface temperature monitoring |
| Data Logging | Automated temperature vs. time acquisition |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | VF-1 |
| Compliance Standards | ASTM D6413, ISO 6941, GB/T 5455, CFR 1615/1616, CA TB117 |
| Chamber Material | Stainless Steel (304) |
| Viewing Window | Tempered Borosilicate Glass |
| Burner Adjustment | Linear Sliding Rail with Precision Needle Valve |
| Sample Holder Options | Multiple Interchangeable Fixtures for Woven, Knitted, and Nonwoven Textiles |
| Flame Height Range | 10–50 mm (adjustable via calibrated needle valve) |
| Ignition Source | Laboratory-grade Bunsen-type Gas Burner (Propane or Butane) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | CCA |
| Compliance | GB/T 16172–2007, ISO 5660-1/2/3/4:2002, ASTM E1354–2011 |
| Radiant Heat Flux Range | 0–100 kW/m² |
| Mass Loss Measurement | 0–2000 g ±0.1 g |
| Oxygen Analysis | 0–25% vol, ±0.1% accuracy |
| CO₂/CO Detection | 0–10% / 0–1% vol, ±0.1% accuracy |
| Exhaust Flow Control | 0.024 m³/s min, variable via inverter-driven fan |
| Laser Smoke Density System | He–Ne source (632.8 nm), ±2% stability over 8 h |
| Data Acquisition | Advantech industrial modules, 3000 Vdc isolation, 50/60 Hz auto-filtering |
| Software | VB-based, GLP-compliant, with full calibration traceability and audit trail |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | NCF |
| Compliance | ISO 1182, GB/T 5464, BS 476-4 & BS 476-11, IMO FTP Code Part 1 |
| Temperature Control Range | 750 ± 5 °C |
| Heating Method | Radiant Tube with Kanthal® Resistance Band |
| Thermocouple Type | OMEGA™ Type K (NiCr-NiAl) |
| Temperature Monitoring Points | Furnace Chamber, Specimen Surface, Specimen Center |
| Calibration Capabilities | 360° Rotatable & Vertically Adjustable Thermocouple Scanning System for Furnace Wall and Internal Temperature Mapping |
| Airflow Stabilization | PTFE-Coated Stainless Steel Inverted Conical Air Stabilizer and Cylindrical Flow Guide |
| Software | Integrated Windows-Based Data Acquisition, Real-Time Curve Plotting, Automated Report Generation (PDF/Excel), ASTM/ISO-Compliant Data Logging with Timestamped Audit Trail |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SBI |
| Compliance | EN 13823, GB/T 20284 |
| Heat Release Rate Measurement | Oxygen consumption calorimetry |
| Smoke Measurement | Optical density (light extinction) via white-light beam |
| Flame Spread Assessment | Lateral flame spread (LFS) up to 1.5 m × 1.0 m specimen edge |
| Droplet Collection | Integrated metal drip tray with thermal shielding |
| Chamber Dimensions | 3 m × 3 m × 2.4 m (W × D × H) |
| Ignition Source | 31 kW propane corner burner (250 mm × 250 mm × 80 mm) mounted on specimen trolley |
| Sampling Duct | Stainless-steel duct with integrated probe zone for multi-parameter gas analysis |
| Data Acquisition | Simultaneous sampling of O₂, CO, CO₂, flue gas temperature, mass flow, and optical density |
| Analyzer Specifications | Siemens OXYMAT 61 (0–25% O₂, ±1% FS/week drift, <3 s response), U23 NDIR (CO: 0–1%, CO₂: 0–10%, ±0.5% FS linearity) |
| Calibration Support | Full software-based calibration routines per ISO 5660-1 and EN 13823 Annex B |
| Brand | MOTIS |
|---|---|
| Model | TPP |
| Origin | Shanghai, China |
| Compliance | NFPA 1971, ASTM D4018, GB 8965.1–2009, ISO 12749 |
| Heat Source | Dual Meker burners (38 mm, 5/16″ orifice) + 9× T150 quartz IR tubes |
| Total incident heat flux | 83 kW/m² ± 2 kW/m² |
| Radiant flux range | 13–40 kW/m² ± 4 kW/m² |
| Convection source | 800–1200 BTU/h per burner |
| Calibrated water-cooled heat flux sensor | 0–100 kW/m², response <200 ms, emissivity >0.95 |
| Data acquisition | 20 Hz (50 ms interval), 0.1 °C resolution, ±0.75 °C accuracy, cold-junction compensation |
| Gas control | Rotameter (±2% accuracy, >3 L/min), pressure regulator (0–15 psi), quarter-turn shutoff valve |
| Brand | MOTIS |
|---|---|
| Model | CFRT |
| Application | Fire resistance testing of low-voltage power cables (≤ 0.6/1.0 kV) |
| Compliance | GB/T 19216.11 (equivalent to IEC 60331-11) |
| Ignition Source | AGF propane ribbon burner (500 mm length, 15 mm nominal width, triple-row 1.32 mm diameter orifices) |
| Temperature Calibration | Omega 1.5 mm sheathed thermocouple |
| Gas Control | Imported mass flow controllers (accuracy ≥ ±1.5%) |
| Air–Fuel Mixing | Venturi-type premixing system |
| Voltage Control | Programmable via PC interface or front-panel adjustment |
| Continuity Monitoring | 0.25 A DC test current per conductor, LED-based real-time circuit integrity indication |
| Data Acquisition | Digital multichannel logging of voltage, current, gas flow, air flow, and thermocouple temperature |
| Safety Protection | D-II type fuse per GB 13539.5 (2 A), imported miniature circuit breakers per test circuit |
| Flame Stabilization | Automatic closed-loop control of propane/air ratio for stable 750 °C or 950 °C flame profile |
| Software Features | Standard-compliant report generation, pre-test parameter configuration (cable specs, standard selection, max duration), audit-trail-capable data logging, calibration history management (≥10 min stabilized acquisition) |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SDB |
| Compliance Standards | ASTM E662, ISO 5659-2, NES 711 |
| Internal Chamber Dimensions | 914 × 914 × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution: 0.0001% |
| Radiation Sources | ASTM E662 radiant heater (25 kW/m²), ISO 5659-2 conical heater (50 kW/m²), dual-standard flame burners |
| Temperature Control | External auxiliary heating jacket |
| Safety Features | Explosive-relief aluminum foil lining, pressure-regulated vent port with capacity bottle, top/bottom pneumatic actuators |
| Cooling | Integrated recirculating water chiller (MEDTHERM water-cooled heat flux meter included, NIST-traceable calibration certificate provided) |
| Weighing System | 0–5000 g capacity, 0.01 g readability |
| Optical Calibration | Motorized ND2 neutral density filter wheel with Clear/Filter/Dark auto-selection |
| Light Source | Uniform incandescent collimated beam |
| Data Interface | Touchscreen PC with integrated reporting and thermal gravimetric analysis (TGA) module |
| Optional Add-ons | Dräger gas detection tubes, FTIR coupling interface for smoke gas speciation |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | NFP-1 |
| Compliance | NFPA 701 (2004 & 2009 Ed.), Test Method 1 |
| Burner Type | Meker Burner |
| Heat Output | 10,500 BTU/hr |
| Ignition | Automatic spark ignition |
| Burn Duration | Fixed 20 s ± 0.1 s |
| Timer Resolution | 0.1 s |
| Sample Holder | Standard ASTM/NFPA-compliant specimen clamp |
| Max Fabric Areal Density | 700 g/m² (21 oz/yd²) |
| Chamber Construction | Calcium silicate board lined with stainless steel exterior |
| Configuration | Open-top vertical combustion chamber |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | RFS |
| Standards Compliance | ASTM E162, ASTM E365, ASTM D3675 |
| Radiant Panel Dimensions | 300 × 460 mm |
| Reflector Surface | 305 × 457 mm, Porous Cement |
| Max Reflector Temp | 815 °C |
| Calibration Burner | Methane (95% purity, 20 L/min @ 150 mbar) |
| Pilot Burner | Acetylene (0.5 L/min @ 150 mbar) |
| Propane Burner | 1.0 L/s @ 20 mbar |
| Compressed Air Supply | 50 L/s @ 700 Pa water column |
| Exhaust Airflow Velocity | 0.5 m/s ±0.05 m/s |
| Black-Body Temperature Control Range | 180–230 °C (±5 °C accuracy) |
| Heat Flux Measurement Range | 0–100 kW/m² (±10% full scale, Schmidt-Boelter type) |
| Data Acquisition | GPIB/USB interface DAQ system with 19" touchscreen control unit |
| Frame Dimensions | 1850 H × 700 D × 1250 L mm |
| Electrical Supply | 220 V AC, 60 Hz, 12 A |
| Brand | MEI/Marlin Engineering |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME1500-3 + ME1700-3 |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BFT |
| Pricing | Available Upon Request |
| Compliance | ASTM D4151 |
| Construction | Stainless Steel Enclosure with Tempered Glass Viewing Window |
| Ignition Source | No. 18 Needle Burner (Adjustable Flame Height) |
| Timing Resolution | 0.01 s |
| Accessories | Standardized Brushing Device, Sample Holder Assembly, Stainless Steel Specimen Clamps |
| Brand | MEI / Marlin Engineering |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME1500-1/3 |
| Pricing | Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SBI- |
| Compliance | GB/T 20284-2006, EN 13823 |
| Power Supply | 380 V AC, 50 Hz |
| Fuel | 95% commercial propane |
| Exhaust Flow Rate | ≥8000 m³/h |
| Gas Flow Control | Mass flow controller (0–2.3 g/s C₃H₈, ±1% FS accuracy) |
| Temperature Measurement | K-type thermocouples (±0.5 °C) |
| Pressure Sensing | Differential pressure transducers (±0.5 Pa) |
| Oxygen Analysis | 0–25% vol, T90 ≤ 2 s, linearity < ±0.1% O₂ |
| CO/CO₂ Analysis | CO (0–1% vol, ±0.02% vol), CO₂ (0–10% vol, ±1% FS), T90 ≤ 2 s |
| Smoke Measurement | White-light extinction method (24 V, 6 W incandescent source |
| Data Acquisition | NI-compatible 16-bit analog input modules, LabVIEW-based real-time system |
| Cooling System | Active chiller (≤5 °C operational setpoint) |
| Filtration | Dual-stage (coarse ≤25 µm, fine ≤3 µm) |
| Exhaust Duct | J-shaped double-walled 304 stainless steel (ID 315 mm) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | RCF |
| Compliance | GB/T 30735-2014, ENV 1187 (t1), ISO 12468-1 |
| Sample Mounting Angle Range | 0–50° |
| Air Duct Adjustment Range | 0–35° |
| Airflow Capacity | up to 250 m³/min |
| Fan Motor Power | 5.5 kW |
| Radiation Panel Dimensions | 600 mm × 600 mm |
| Ignition Method | Electric Spark with Thermocouple-Monitored Flame Supervision |
| Wind Speed Measurement | Three Vane Anemometers (±0.1 m/s accuracy) |
| Construction Materials | SUS304 Stainless Steel Duct (2 mm thickness), Structural Steel Frame with Pneumatic & Servo-Driven Actuation |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SCT |
| Pricing | Available Upon Request |
| Brand | MOTIS |
|---|---|
| Model | VFT |
| Standard Compliance | ISO 15025, AQ 6103–2007 |
| Ignition Source | Propane burner |
| Ignition Duration | Adjustable (default 10 s) |
| Sample Orientation | Vertical |
| Measured Parameters | Afterflame time, afterglow time, char length |
| Burner Control | Stepper motor–actuated angular positioning for bottom-edge and edge ignition |
| Display | Integrated LCD interface |
| Power Supply | 220 V, 50 Hz |
| Ambient Conditions | 20 ± 2 °C, 65 ± 5 % RH |
| Dimensions (W × H × D) | 410 × 900 × 380 mm |
| Gas Supply | Propane |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | CCT |
| Heating Source | 5 kW Cone Heater (0–100 kW/m²) |
| Sample Capacity | 100 mm × 100 mm × 50 mm |
| Mass Measurement Range | 0–3000 g (±0.1 g) |
| Oxygen Analyzer | ABB Paramagnetic (0–25% O₂) |
| CO/CO₂ Analyzers | ABB NDIR (CO: 0–1% |
| CO₂ | 0–10%) |
| Smoke Measurement | He-Ne Laser System (632.8 nm) |
| Exhaust Flow Control | 0–50 g/s (±0.1 g/s) |
| Heat Flux Calibration | NIST-Traceable Foil Heat Flux Meter (0–100 kW/m², ±3% accuracy) |
| Compliance | ISO 5660-1 & -2, ASTM E1354, GB/T 16172, BS 476-15 |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | GCF |
| Compliance | GB/T 29416–2012 Annex C, BS 8414 |
| Temperature Control | Programmable controller with standardized temperature ramp profile |
| Test Duration | 24 h continuous monitoring |
| Thermocouple Configuration | Internal furnace thermocouples + surface-mounted sample thermocouples |
| Data Logging | Real-time temperature display and curve plotting |
| Pass/Fail Criteria | Based on thermal trajectory divergence (sample center temperature vs. furnace ambient temperature) |
| Software Functionality | Automated test execution, time-synchronized thermal data acquisition, and smoldering propensity classification per GB/T 29416–2012 |
Show next