Macro SpinColumnTM
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Macro SpinColumnTM |
| Pricing | Upon Request |
Overview
The Macro SpinColumnTM is a high-capacity, centrifugation-based sample preparation device engineered for efficient nucleic acid or protein purification from small-volume biological samples. Designed using standardized spin-column architecture, it operates on the principle of solid-phase reversible binding—where target biomolecules selectively adsorb to a functionalized silica or polymer matrix under optimized chaotropic salt and pH conditions, while contaminants are removed via sequential wash steps. Following elution with low-ionic-strength buffer (e.g., TE or nuclease-free water), purified analytes are recovered with high yield and integrity. Its 75–150 µL input volume range and 30–300 µg binding capacity per tip make it particularly suitable for concentrating dilute samples or processing limited clinical specimens—such as CSF, microdissected tissue lysates, or low-yield cell culture supernatants—without requiring pre-concentration or pooling.
Key Features
- Optimized binding matrix delivering consistent recovery across the full 30–300 µg capacity range per column
- Centrifuge-compatible design validated for standard fixed-angle and swing-bucket rotors (max. RCF: 16,000 × g)
- Low-binding polypropylene housing minimizing nonspecific adsorption of nucleic acids and proteins
- Pre-assembled, sterile-filtered columns supplied in individual foil-sealed pouches for ambient storage and immediate use
- No vacuum manifolds or specialized equipment required—fully compatible with standard laboratory centrifuges
- Batch-to-batch performance verified per ISO 13485-compliant manufacturing controls
Sample Compatibility & Compliance
The Macro SpinColumnTM supports diverse upstream lysis chemistries, including guanidine-thiocyanate, SDS-based, and enzymatic digestion protocols. It has been empirically validated for use with human plasma, serum, whole blood (post-hemolysis control), urine sediment, formalin-fixed paraffin-embedded (FFPE) tissue lysates, and bacterial/viral lysates. All components are certified DNase-, RNase-, and endotoxin-free (≤0.01 EU/mL), meeting requirements for molecular diagnostic workflows under CLIA and CAP-accredited laboratories. The device conforms to ISO 10993-5 (cytotoxicity) and ISO 10993-10 (irritation/sensitization) biocompatibility standards. While not an IVD device itself, it is routinely deployed in FDA 510(k)-cleared assay workflows and supports GLP-compliant sample prep documentation when integrated with electronic lab notebooks (ELNs).
Software & Data Management
As a benchtop consumable, the Macro SpinColumnTM does not incorporate embedded electronics or firmware. However, its usage is fully traceable within LIMS and ELN platforms via configurable lot-level tracking. Each production lot includes a Certificate of Analysis (CoA) documenting binding capacity validation (n = 12 columns per lot), endotoxin testing, and sterility assurance (USP ). For regulated environments, raw CoA data and manufacturing records are retained for ≥10 years and available upon audit request. Integration with instrument-agnostic digital SOPs (e.g., via LabVantage or Thermo Fisher SampleManager) enables automated step logging, operator authentication, and deviation flagging during centrifugation time/RCF verification.
Applications
- High-yield isolation of genomic DNA from low-cellularity samples (e.g., circulating tumor DNA in plasma)
- Purification of total RNA from FFPE sections prior to NGS library construction
- Concentration and desalting of antibody fragments or recombinant proteins following affinity chromatography
- Removal of primers, dNTPs, and enzymes post-PCR or in vitro transcription reactions
- Pre-analytical processing of cerebrospinal fluid (CSF) for Alzheimer’s disease biomarker assays (e.g., Aβ42, p-tau181)
- Recovery of exosomal RNA from ultracentrifugation pellets without ultrasonication-induced degradation
FAQ
What is the recommended centrifugation speed and time for optimal binding and wash efficiency?
Standard protocol specifies 12,000 × g for 30 seconds during binding, followed by two 12,000 × g / 30-second washes with provided buffer. Elution requires 12,000 × g for 1 minute after incubation.
Can the Macro SpinColumnTM be used with magnetic bead-based workflows?
No—it is a gravity- and centrifugation-driven format only; magnetic separation compatibility is not supported.
Is the column compatible with automated liquid handlers?
Yes, the standardized 2 mL collection tube footprint and column height enable integration with common deck layouts on Hamilton STAR, Tecan Freedom EVO, and Agilent Bravo systems using custom tip offsets.
How should unused columns be stored after opening the pouch?
Store at room temperature in the original sealed pouch; avoid repeated exposure to humidity. Do not refrigerate or freeze.
Does the product include elution buffer or wash buffers?
Buffers are sold separately as part of the Macro SpinColumnTM Kit (Cat. No. MSC-KIT-01); standalone columns are consumable-only units.