Empowering Scientific Discovery

Environmental Test Chamber for PVC Sheet Testing – Temperature and Humidity Controlled Chamber

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin Imported
Manufacturer Type Authorized Distributor
Price USD 3,100 (approx.)

Overview

The Environmental Test Chamber for PVC Sheet Testing is a precision-engineered temperature and humidity controlled chamber designed specifically for evaluating the dimensional stability, mechanical integrity, and aging behavior of polyvinyl chloride (PVC) sheets under standardized climatic stress conditions. It operates on the principle of forced-air convection with dual independent control loops for temperature and relative humidity (RH), enabling stable, repeatable exposure profiles across wide operational ranges. The chamber complies with fundamental requirements of IEC 60068-2 series environmental testing standards and serves as a core platform for accelerated aging, storage simulation, and quality conformance verification in polymer manufacturing, building materials R&D, and regulatory pre-compliance screening.

Key Features

  • Robust stainless-steel interior with seamless welding and anti-corrosion coating—optimized for long-term exposure to high-humidity and condensation-prone cycles.
  • Advanced Balanced Temperature and Humidity Control (BTHC) system employing PID-driven SSR output to dynamically match heating/humidification energy input with thermal and moisture load losses—ensuring ±0.5 °C temperature uniformity and ±2.0 % RH stability (at 25 °C / 60 % RH, unloaded).
  • Full-capillary refrigeration circuit with automatic capacity modulation—eliminates mechanical expansion valve hysteresis, delivering smoother cooling transitions and improved low-temperature ramp reproducibility down to −70 °C.
  • 7-inch high-resolution capacitive touch HMI controller with multi-language UI (English, German, Chinese), built-in data logging (10,000-point memory), and USB export capability.
  • Modular structural design supporting custom internal dimensions (up to 10 m³), optional walk-in configuration, and integration-ready interfaces (RS-485, Ethernet, dry-contact alarms).
  • Comprehensive safety architecture including over-temperature cutoff, compressor high-pressure protection, humidity sensor self-diagnosis, and door-open interlock.

Sample Compatibility & Compliance

This chamber accommodates flat-sheet specimens up to 2.4 m × 1.2 m × 50 mm (L×W×H), with adjustable stainless-steel shelves and non-reactive airflow baffles to ensure uniform exposure across PVC substrates—including rigid, flexible, plastisol-coated, and flame-retardant formulations. It meets the essential performance criteria specified in GB/T 5170.2–2017 (temperature test equipment calibration), GB/T 5170.5–2017 (humid heat test equipment calibration), and aligns with technical foundations of ISO 17025-accredited laboratories. While not certified to ASTM D618 or ISO 291 directly, its operational envelope supports test protocols derived from those standards—including conditioning per ASTM D4329 (UV + condensation), ASTM D5208 (light + humidity), and ISO 4892-2 (Xenon arc). All controllers include audit-trail-enabled operation logs compliant with GLP documentation requirements.

Software & Data Management

The embedded controller supports real-time monitoring, programmable multi-step profiles (up to 99 segments), and cycle interruption/resume functionality. Optional PC-based software (OC-View Pro) provides remote supervision via TCP/IP, automated report generation (PDF/CSV), trend analysis with statistical process control (SPC) overlays, and 21 CFR Part 11-compliant user access levels (administrator, operator, reviewer) with electronic signature support. Data integrity safeguards include cyclic redundancy check (CRC) validation, write-protected archive mode, and timestamped event logs covering all parameter changes, alarm triggers, and manual interventions.

Applications

  • Pre-conditioning of PVC sheets prior to tensile, impact, or peel adhesion testing per ASTM D638 or ISO 527.
  • Accelerated weathering simulation for outdoor signage, roofing membranes, and cable sheathing materials.
  • Storage stability assessment under tropical (40 °C / 95 % RH) or arctic (−40 °C) conditions per IEC 60068-2-1/2/30.
  • Validation of PVC formulation resistance to hydrolysis, plasticizer migration, and surface whitening (blooming).
  • Supporting ISO 9001:2015 clause 8.5.1 (control of production and service provision) through documented environmental conditioning records.

FAQ

What is the typical temperature range for this chamber?
Standard configuration covers −70 °C to +150 °C; humidity range spans 20 % to 98 % RH (non-condensing at extremes). Custom low-temp variants down to −80 °C are available upon request.
Does the chamber support programmable cycling between temperature and humidity setpoints?
Yes—supports up to 99-step programs with ramp rate control (0.1–5.0 °C/min), dwell time definition, and simultaneous RH modulation synchronized to temperature transitions.
How is calibration traceability ensured?
Each unit ships with a factory calibration certificate referencing NIST-traceable standards; optional UKAS-accredited third-party calibration services are available for ISO/IEC 17025 compliance.
Can the chamber be integrated into an existing laboratory LIMS or MES system?
Yes—via Modbus TCP or OPC UA protocol adapters; API documentation and driver libraries are provided for LabVIEW, Python, and MATLAB integration.
What maintenance intervals are recommended for long-term reliability?
Compressor oil and refrigerant filter replacement every 24 months; humidity sensor recalibration annually; full system performance verification per GB/T 5170.2 & 5170.5 every 12 months.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0