Empowering Scientific Discovery

VACUUBRAND PC 3016 NT VARIO Variable-Speed Chemical Vacuum System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand VACUUBRAND®
Origin Germany
Model PC 3016 NT VARIO
Pump Type Oil-Free Diaphragm Vacuum Pump
Number of Pump Heads 8
Maximum Flow Rate 19.3 m³/h (11.4 cfm)
Ultimate Vacuum (Absolute) 70 mbar (53 torr)
Ultimate Vacuum with Gas Ballast 100 mbar (75 torr)
Motor Speed Range 30–2400 rpm
Rated Motor Power 0.53 kW
Noise Level 47 dBA (at 50 Hz)
Dimensions (L×W×H) 616 × 387 × 420 mm
Weight 29.7 kg
Inlet Port KF DN 25 flange / DN 15 mm hose nipple
Outlet Port DN 10 mm hose nipple
Cooling Water Connections 2 × DN 6–8 mm
Ambient Operating Temperature 10–40 °C
IP Rating IP 40
ATEX Certification II 3G IIC T3 X (230 V only)

Overview

The VACUUBRAND PC 3016 NT VARIO is an engineered oil-free diaphragm vacuum system designed for precision-controlled, high-throughput solvent removal in analytical, preparative, and process-scale laboratory applications. Based on proven Couette-flow–optimized multi-stage diaphragm technology, the system delivers stable, pulse-free vacuum across a wide operational range—from rough vacuum (100 mbar) down to 70 mbar absolute—without oil contamination or hydrocarbon backstreaming. Its eight-head NT-series architecture ensures mechanical robustness, thermal stability, and long-term reproducibility under continuous duty cycles typical of rotary evaporation, freeze drying, vacuum filtration, and distillation workflows. Unlike fixed-speed alternatives, the VARIO drive enables real-time vacuum regulation via closed-loop motor speed modulation, eliminating pressure overshoot and hysteresis during dynamic load changes—critical for sensitive crystallization, concentration, or reactive chemistry protocols.

Key Features

  • Variable-speed motor control (30–2400 rpm) enabling true proportional vacuum regulation without solenoid valves or throttling orifices
  • Integrated CVC 3000 vacuum controller with intuitive text-based menu, built-in vent valve, and programmable setpoint ramping
  • Dual-stage condensation management: inlet AK separator bottle prevents liquid carryover and particulate ingress; exhaust EK cold trap achieves >95% solvent recovery efficiency for acetone, ethyl acetate, methanol, and other low-boiling organics
  • Eight-diaphragm head configuration delivering 19.3 m³/h free-air displacement at low noise emission (47 dBA), optimized for shared lab environments
  • Corrosion-resistant PTFE-coated pump chambers and FKM elastomers compatible with aggressive vapors including HCl, HNO₃, and halogenated solvents
  • IP 40-rated enclosure with dual cooling-water inlets (DN 6–8 mm) for sustained operation up to 40 °C ambient temperature
  • ATEX-certified variant (II 3G IIC T3 X) available for use in Zone 2 hazardous atmospheres when operated at 230 V

Sample Compatibility & Compliance

The PC 3016 NT VARIO is validated for use with aqueous, organic, and mildly corrosive vapor streams encountered in ISO/IEC 17025-accredited QC laboratories and GLP-compliant R&D settings. Its oil-free operation eliminates risk of sample cross-contamination—a requirement under USP , FDA 21 CFR Part 11, and EU GMP Annex 15 for sterile processing support systems. The CVC 3000 controller logs timestamped vacuum profiles and setpoint deviations, supporting audit-ready data integrity when paired with optional Ethernet or RS-485 interfaces. All wetted materials comply with FDA 21 CFR 177.2600 (food-contact polymers) and EU Regulation (EC) No. 1935/2004. CE marking confirms conformity with Machinery Directive 2006/42/EC and Electromagnetic Compatibility Directive 2014/30/EU.

Software & Data Management

While the CVC 3000 operates as a standalone controller with local LCD interface, it supports external integration via analog 0–10 V input/output and digital Modbus RTU (RS-485). Lab automation platforms—including LabVIEW, MATLAB, and DeltaV—can read real-time vacuum values, motor speed, and fault status. Audit trails are maintained internally for ≥10,000 events with time/date stamping, meeting ALCOA+ principles for electronic records. Optional firmware upgrades enable password-protected user roles, electronic signature capture, and CSV export of vacuum trend logs—fully aligned with 21 CFR Part 11 Subpart B requirements for electronic signatures and record retention.

Applications

  • Automated rotary evaporation of heat-sensitive APIs and natural product extracts under controlled vacuum gradients
  • High-yield solvent recovery in kilo-lab synthesis where VOC emissions must meet ISO 14001 environmental management criteria
  • Vacuum-assisted crystallization of chiral intermediates requiring sub-mbar stability over 72-hour runs
  • Parallel sample preparation for LC-MS analysis, where consistent degassing across 96-well plates demands zero-pressure fluctuation
  • Support of lyophilization cycle development, particularly primary drying phases requiring precise vapor pressure control
  • In-line vacuum monitoring during glovebox purging or inert-atmosphere reactor venting

FAQ

Does the PC 3016 NT VARIO require routine oil changes or lubrication?
No. As a fully oil-free diaphragm system, it contains no rotary vane oil or greased bearings—eliminating scheduled oil maintenance, disposal costs, and associated downtime.
Can the EK cold trap be used with water-cooled condensers?
Yes. The EK unit accepts standard chilled water (5–15 °C) via its dual DN 6–8 mm ports; glycol-water mixtures are also compatible for sub-zero trapping of low-volatility solvents.
Is the CVC 3000 controller compatible with LIMS or ELN systems?
Yes—via Modbus RTU or analog 0–10 V signals. Integration kits and driver libraries are available for Thermo Fisher SampleManager, LabWare LIMS, and Benchling ELN.
What is the expected diaphragm lifetime under continuous operation?
Under typical lab conditions (20 °C, 50% duty cycle), VACUUBRAND specifies ≥15,000 operating hours before replacement—validated per DIN EN 60068-2-64 vibration endurance testing.
Does the system meet ISO 8573-1 Class 0 air purity requirements?
Yes. As an oil-free vacuum source, it satisfies ISO 8573-1:2010 Class 0 for total oil content (<0.01 mg/m³), making it suitable for cleanroom-compatible vacuum manifolds and semiconductor-grade drying processes.