Empowering Scientific Discovery

Alphavita MVC-1300 Ductless Fume Hood

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Alphavita
Model MVC-1300
Type Ductless (Recirculating) Fume Hood
Construction Fully Steel Cabinet with Epoxy-Polyester Coated Galvanized Steel
Filter System Modular Dual-Layer Molecular Filtration (4 Standard PP-Housed Filters)
Face Velocity Range 0.4–0.6 m/s
Airflow Volume 480 m³/h
External Dimensions (W×D×H) 1300 × 790 × 920–1502 mm
Internal Dimensions (W×D×H) ≥1286 × 690 × 760 mm
Filter Capacity IPA ≥500 g, Cyclohexane ≥750 g, HCl ≥1620 g
TVOC Detection Resolution 0.1 ppm
Face Velocity Sensing Accuracy ±0.1 m/s
Display 3.5-inch LED Smart Panel (real-time temp, fan speed, face velocity, filter life countdown, inlet/outlet TVOC)
Connectivity Optional Wi-Fi/4G-enabled EMonitor App (remote monitoring, alarm push notifications, parameter adjustment)
Compliance JG/T 385–2012, GBZ/T 160.55, third-party public liability insurance ≥¥5 million RMB
Waste Filter Handling Certified industrial hazardous waste disposal provider engagement documented

Overview

The Alphavita MVC-1300 is a fully steel, ductless (recirculating) fume hood engineered for safe, localized containment and chemical vapor abatement in laboratories where external ductwork is impractical or prohibited. Unlike conventional ducted hoods that exhaust air to the exterior, the MVC-1300 employs a closed-loop airflow architecture: ambient laboratory air is drawn across the work surface at a controlled face velocity (0.4–0.6 m/s), passed through a modular, multi-stage molecular filtration system, and returned as purified air into the room. This design eliminates structural modifications, reduces HVAC load, and supports energy-efficient operation—while maintaining rigorous compliance with JG/T 385–2012, China’s national standard for ductless fume hood performance and safety. Its core function is not ventilation per se, but *dynamic chemical adsorption*: leveraging high-capacity, chemically selective activated carbon and impregnated media to capture volatile organic compounds (VOCs), acidic gases (e.g., HCl), and solvent vapors—including acetone, isopropanol, and cyclohexane—with quantifiable retention metrics validated against standardized challenge agents.

Key Features

  • Modular dual-layer molecular filtration system with four standardized polypropylene-housed filters—configurable for liquid vapors, particulates, or mixed-phase hazards; certified adsorption capacity: ≥500 g for isopropanol, ≥750 g for cyclohexane, ≥1620 g for hydrochloric acid vapor.
  • Real-time environmental monitoring via integrated 3.5-inch LED smart display: shows face velocity (±0.1 m/s accuracy), fan RPM, cabinet internal temperature, filter service-life countdown, and dual-point TVOC concentration (inlet and outlet; resolution 0.1 ppm; user-definable alarm thresholds).
  • Structural integrity assured by cold-rolled galvanized steel frame with baked-on epoxy-polyester coating—resistant to corrosion from acids, bases, and solvents; work surface options include chemical-resistant epoxy resin or tempered safety glass.
  • Energy-efficient EC centrifugal blower with variable-speed control—maintains stable negative pressure across the sash opening while enabling operator-adjusted airflow to match experimental volatility and reagent load.
  • Optional EMonitor wireless connectivity module: enables remote access via iOS/Android app over Wi-Fi or 4G; delivers real-time parameter visibility, push notifications for filter exhaustion or TVOC excursions, and audit-ready event logs—even when the app is backgrounded or closed.

Sample Compatibility & Compliance

The MVC-1300 is validated for routine use with over 500 common laboratory chemicals, including halogenated solvents, alcohols, ketones, and inorganic acids. Its filtration efficacy is benchmarked using JG/T 385–2012 test protocols: residual acetone concentration post-filtration remains ≤0.25 mg/m³ (per GBZ/T 160.55), and sulfur hexafluoride (SF₆) breakthrough is limited to <0.5 ppm under worst-case challenge conditions. All units undergo third-party verification of structural integrity and airflow uniformity. The manufacturer maintains statutory public liability insurance coverage exceeding ¥5 million RMB, underwritten by a Class-A national insurer. Spent filters are managed exclusively through an authorized industrial hazardous waste handler holding valid National Hazardous Waste Operating Permit (HWOP) certification—ensuring full traceability and environmentally compliant deactivation and disposal per GB 5085.3–2007.

Software & Data Management

The optional EMonitor system provides ISO/IEC 17025-aligned data governance: all sensor readings, fan adjustments, alarm triggers, and filter lifecycle events are time-stamped and stored locally on-device with encrypted cloud backup. Audit trails comply with GLP and GMP documentation requirements, supporting 21 CFR Part 11 readiness when configured with user authentication and electronic signature modules. Data export is supported in CSV and PDF formats; historical trends (e.g., TVOC drift, face velocity stability) can be visualized over custom date ranges. No proprietary drivers or OS-specific software are required—web-based configuration is accessible via standard browsers on desktop or mobile platforms.

Applications

The MVC-1300 serves as a primary containment solution for low-to-moderate volatility procedures in QC labs, academic teaching facilities, pharmaceutical formulation suites, and R&D environments where permanent duct installation is constrained. Typical use cases include weighing of reference standards, preparation of calibration solutions, handling of cytotoxic compounds under ISO Class 5 laminar flow supplementation, solvent-based sample extraction, and small-scale synthesis involving non-pyrophoric reagents. It is not intended for perchloric acid, hydrogen sulfide, or radioactive aerosol applications—nor for processes generating significant heat, high particulate load (>5 mg/m³), or uncharacterized novel compounds without prior filter compatibility assessment.

FAQ

What standards does the MVC-1300 comply with?
It conforms to JG/T 385–2012 (Chinese standard for ductless fume hoods), GBZ/T 160.55 (acetone detection limit), and incorporates engineering controls aligned with ANSI Z9.5 and EN 14175–5 principles.
Can the filtration system be customized for specific chemicals?
Yes—Alphavita offers application-specific filter configurations beyond the standard four-carbon module; users must submit SDS documentation for technical review prior to deployment.
Is the unit suitable for use with nitric acid or ammonia?
Standard filters are not optimized for strong oxidizers (e.g., nitric acid) or alkaline gases (e.g., ammonia); alternative impregnated media configurations are available upon request and validation.
How often must filters be replaced?
Service life depends on cumulative exposure mass and compound type; the smart display calculates remaining capacity based on real-time TVOC uptake and runtime—typical replacement intervals range from 6 to 18 months under normal usage.
Does the hood require annual third-party certification?
Per JG/T 385–2012, initial commissioning verification and biannual performance testing (face velocity mapping, containment check, filter efficiency spot-check) are recommended; Alphavita provides certified field service technicians for scheduled maintenance.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0