Empowering Scientific Discovery

Ailun AC-100 Rapid COD Digestion System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Ailun General / Qingdao Ailun
Origin Shandong, China
Manufacturer Type Authorized Distributor
Country of Origin China
Model AC-100
Digestion Method Rapid Closed-Vessel Catalytic Digestion
Heating Module Single Aluminum Alloy Heating Block
Batch Capacity 17 samples
Temperature Range 32–399 °C
Temperature Accuracy ±1 °C
Digestion Volume Capacity 1700 mL (total, distributed across 17 positions)
Timer Accuracy ±0.1 s at 10 min setting

Overview

The Ailun AC-100 Rapid COD Digestion System is a precision-engineered thermal digestion platform designed for compliant, high-throughput chemical oxygen demand (COD) determination in aqueous environmental matrices. It operates on the principle of rapid closed-vessel catalytic digestion—standardized in Standard Methods for the Examination of Water and Wastewater, 4th Edition—where samples are heated under acidic, oxidizing conditions (typically using potassium dichromate in concentrated sulfuric acid with silver sulfate catalyst) to fully oxidize organic matter. The system’s robust cast-aluminum heating block ensures uniform thermal distribution and rapid ramp-up to target temperatures (32–399 °C), enabling precise replication of method-defined digestion protocols—including those for high-salinity industrial effluents where chloride interference mitigation is critical. Unlike open-reflux or conventional hotplate-based systems, the AC-100 supports sealed-tube digestion, minimizing reagent loss, operator exposure, and analytical variability.

Key Features

  • Single high-integrity aluminum alloy heating block with optimized thermal mass and surface emissivity for stable temperature maintenance (±1 °C) across all 17 sample positions
  • Rapid thermal response: reaches 150 °C in under 8 minutes and maintains setpoint stability within ±0.5 °C during extended 2-hour digestion cycles
  • Dedicated timer with high-resolution quartz-controlled accuracy (±0.1 s at 10-minute interval), programmable for up to 180 minutes to accommodate ASTM D1252–22 (Method B) and ISO 6060 protocols
  • Integrated safety interlock system prevents operation without proper lid engagement; over-temperature cutoff safeguards against thermal runaway
  • Compact footprint (280 × 220 × 180 mm) and low power consumption (≤800 W) suitable for shared laboratory bench space and multi-user environments
  • Chemical-resistant anodized housing and PTFE-coated sample well inserts ensure long-term durability against aggressive H2SO4/K2Cr2O7 reagents

Sample Compatibility & Compliance

The AC-100 accommodates standard 16-mm OD borosilicate glass digestion tubes (up to 17 per run), supporting both 10 mL and 20 mL reaction volumes. Its wide temperature range (32–399 °C) enables method flexibility—not only for standard COD (e.g., EPA 410.4, ISO 6060), but also for total phosphorus (TP) and total nitrogen (TN) digestion per APHA 4500-P E and 4500-N C. The system meets key regulatory alignment requirements: its temperature accuracy and timer resolution satisfy GLP documentation prerequisites for audit-ready data generation; it supports traceable calibration via NIST-traceable digital thermometers; and its closed-vessel configuration complies with OSHA 29 CFR 1910.1200 (Hazard Communication Standard) by reducing fume generation during Cr(VI) and SO3 evolution. While not certified as GMP-grade equipment, its reproducible thermal profile supports FDA 21 CFR Part 11–compliant workflows when paired with validated LIMS or ELN software.

Software & Data Management

The AC-100 is a standalone hardware platform with no embedded microprocessor or digital interface—intentionally designed for method fidelity and operational simplicity in regulated environmental labs. All parameters (set temperature, duration, ramp rate) are configured manually via dual-knob analog controls with LED readouts. This architecture eliminates firmware vulnerabilities, reduces validation burden, and ensures full compatibility with existing QA/QC documentation systems. Users maintain complete control over protocol execution and generate auditable paper-based or scanned logbook records per ISO/IEC 17025:2017 clause 7.5.2. For laboratories requiring electronic data capture, the system integrates seamlessly with third-party data acquisition modules (e.g., LabVIEW-compatible thermocouple interfaces) or digital timers with USB export functionality.

Applications

  • Routine COD analysis of municipal wastewater influent/effluent per ISO 6060 and ASTM D1252–22
  • High-chloride wastewater characterization (e.g., seawater-influenced discharges, chemical manufacturing effluents) using mercury-free digestion variants
  • Preparation of digested samples for subsequent spectrophotometric quantification (e.g., Hach DR3900, Thermo Scientific Genesys UV-Vis) or titrimetric analysis (e.g., ferrous ammonium sulfate back-titration)
  • Multi-parameter environmental testing workflows where TP, TN, and COD share common digestion steps
  • Educational laboratories conducting AP Chemistry or Environmental Engineering curriculum-aligned experiments with documented method adherence

FAQ

Does the AC-100 support method-specific pre-programmed protocols?

No—the AC-100 uses manual analog controls to ensure full user transparency and eliminate black-box automation. Protocols must be executed per written SOPs.
Can it be used for mercury-free COD digestion methods?

Yes—its adjustable temperature range and stable thermal uniformity enable validated use with AgSO₄–Bi₂(SO₄)₃ catalyst systems for chloride-rich samples.
Is calibration verification required before each batch?

Per ISO/IEC 17025, periodic calibration (at least daily or per batch sequence) using a NIST-traceable reference thermometer is recommended.
What tube types are compatible?

Standard 16-mm OD borosilicate glass digestion tubes (e.g., Hach TNTplus vials, Lovibond COD cuvettes) with maximum height of 150 mm.
Does it include digestion reagents or consumables?

No—reagents, tubes, and cooling racks are supplied separately to allow method-specific selection and vendor qualification.