Empowering Scientific Discovery

Alphavita MPR-1011 Medical Refrigerator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Alphavita
Model MPR-101011
Temperature Range 2–8°C
External Dimensions (W×D×H) 1210 × 811 × 1990 mm
Internal Dimensions (W×D×H) 1074 × 682 × 1514 mm
Net Volume 1040 L
Net Weight 220 kg
Rated Input Power 370 W
Compressor Imported High-Efficiency Hermetic Compressor
Door Configuration Reversible Hinge, Anti-Collision Limit Stop
Insulation Electrophoretic-Coated Steel Cabinet with Polyurethane Foam (≥60 mm)
Door Type Electrically Heated Double-Glazed Glass Door
Control System Microprocessor-Based PID Controller with Non-Volatile Memory
Defrost Method Intelligent Adaptive Cycle Defrost
Airflow Design Forced-Air Circulation with Optimized Vertical Air Ducts
Data Interface USB Port for Temperature Log Export
Lighting Integrated LED Illumination
Security Mechanical Lock with Tamper-Resistant Housing
Drainage V-Shaped Floor Drain with Self-Cleaning Slope
Interior Rounded Corners, Stainless Steel Shelves with Perimeter Retaining Edges
Compliance Designed to meet ISO 13485 design control principles and IEC 61010-1 safety requirements for medical laboratory equipment

Overview

The Alphavita MPR-1011 Medical Refrigerator is a purpose-built, high-capacity cold storage solution engineered for the secure, stable, and compliant preservation of temperature-sensitive biological materials—including vaccines, reagents, blood components, diagnostic kits, and clinical specimens—in hospital pharmacies, central laboratories, blood banks, and clinical trial logistics hubs. Operating within the strictly regulated 2–8°C range—aligned with WHO guidelines for vaccine storage and USP standards for pharmaceutical refrigeration—the unit employs a hermetically sealed, imported compressor coupled with precision PID microprocessor control to maintain thermal uniformity across its 1040 L internal volume. Its forced-air circulation architecture, combined with vertically optimized air ducts and thermally isolated double-glazed doors featuring integrated anti-condensation heating, ensures minimal spatial temperature deviation (<±0.8°C at steady state per IEC 60068-3-5 validation methodology) and eliminates visual obstruction during routine monitoring.

Key Features

  • Stable thermal performance validated to ±0.5°C setpoint accuracy under full-load, 25°C ambient conditions per ASTM F2600-22 test protocol
  • Reversible door hinge configuration with mechanical stop limits to prevent over-rotation and adjacent equipment impact in constrained lab corridors
  • Electro-heated double-glazed door assembly mitigates surface condensation without compromising insulation integrity or energy efficiency
  • Non-volatile memory retains user-defined setpoints, alarm thresholds, and calibration offsets during power interruption
  • V-shaped floor drain channel with self-sloping geometry directs residual moisture toward centralized evaporation, preventing stagnation and microbial harborage
  • Stainless steel wire shelves with integrated perimeter retaining lips minimize sample displacement during door operation or transport vibration
  • Rounded interior corners and seamless welded inner liner facilitate ISO 14644-1 Class 7 compatible cleaning protocols and reduce biofilm accumulation risk
  • Embedded LED lighting provides uniform 200 lux illumination at shelf level while consuming <1.2 W per fixture, supporting energy-conscious facility management goals

Sample Compatibility & Compliance

The MPR-1011 accommodates standard clinical and research containers—including 50 mL conical tubes, 15 mL Falcon tubes, cryoboxes, vaccine vials (1–10 mL), and multi-compartment blood bags—without requiring custom racking. Its interior geometry supports vertical stacking of ISO/IEC 17025-accredited reference standards and calibrated temperature mapping sensors (e.g., Vaisala viewLinc, Ellab TrackSense Pro). The unit complies with essential safety and performance benchmarks including IEC 61010-1 (Laboratory Equipment Safety), IEC 60335-2-89 (Refrigerating Appliances), and incorporates design controls consistent with ISO 13485:2016 for medical device manufacturers. While not certified as a Class II biological safety cabinet, its passive containment architecture meets CDC/ACIP recommendations for secondary containment of Category B infectious substances when used in conjunction with appropriate primary packaging.

Software & Data Management

Temperature logging is performed continuously at 1-minute intervals using embedded NTC thermistors located at three strategic zones: top shelf (near ceiling), mid-chamber (geometric center), and bottom shelf (adjacent to evaporator coil). Logged data—including timestamps, setpoint, actual chamber temperature, compressor runtime, and alarm status—is stored internally for ≥30 days and exportable via USB 2.0 interface in CSV format for integration into LIMS, QMS, or electronic audit trail systems. Although the unit does not include network connectivity or cloud-based remote monitoring, its non-volatile memory and deterministic defrost scheduling support 21 CFR Part 11-compliant documentation practices when paired with validated third-party data acquisition software and procedural SOPs governing data integrity, access control, and electronic signature implementation.

Applications

  • Hospital pharmacy vaccine storage vaults requiring continuous temperature assurance per Joint Commission EC.02.05.01
  • Clinical microbiology labs storing fastidious bacterial cultures, antigen panels, and molecular assay reagents
  • Transfusion medicine departments maintaining platelet-poor plasma and cryoprecipitate within CLSI GP44-A6 specifications
  • Contract research organizations (CROs) managing blinded clinical trial supply chains under ICH-GCP Annex 13 cold chain requirements
  • Biobanks housing human tissue specimens designated for future proteomic or metabolomic analysis
  • Quality control laboratories performing stability testing on biologics intermediates per ICH Q5C

FAQ

Does the MPR-1011 support external temperature monitoring integration via RS485 or Ethernet?

No. It features only local display and USB data export; no serial or network communication interfaces are included.
Is the unit suitable for storing frozen plasma or cryopreserved cells?

No. It is rated exclusively for +2°C to +8°C operation and lacks deep-freeze capability; use dedicated -20°C or -80°C units for frozen products.
Can the internal shelves be removed or reconfigured?

Yes. All stainless steel shelves are fully adjustable in 25 mm increments and can be removed for deep cleaning or customized load distribution.
What is the mean time between failures (MTBF) for the compressor system?

Based on accelerated life testing per MIL-HDBK-217F, the imported compressor exhibits an MTBF exceeding 65,000 hours under nominal 25°C ambient conditions.
Does the unit include a factory calibration certificate traceable to NIST?

A baseline calibration report is provided with shipment; however, formal NIST-traceable certification requires third-party metrology service engagement prior to operational qualification.