OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelPGC5007B
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelFTPA2000-260
TypeOnline Analyzer
PrincipleFourier Transform (FT)
Wavelength Range3800–14000 cm⁻¹
Spectral Resolution1–128 cm⁻¹ (in 2× steps)
Optical Path Difference (OPD) Scan Speed1 cm/s
Wavenumber Repeatability0.002 cm⁻¹ RMS @ 7300 cm⁻¹
Wavenumber Reproducibility0.04 cm⁻¹ RMS @ 7300 cm⁻¹
Absorbance Linearity Error≤0.1% of peak response
SNR (1 scan, 16 cm⁻¹, room-temp InGaAs)≥15,000:1 (29 µabs @ 0 abs)
Sampling ModesTransmission / Diffuse Reflectance / Transflectance
Detector OptionsThermoelectrically Cooled InAs or InGaAs
Channel Count8 independent optical channels (8-in/8-out)
Fiber InterfaceSMA-905
Fiber TypesLow-OH silica core (300–600 µm), multi-fiber bundle (650 µm, NA 0.22–0.28)
Max Fiber Length100 m (solids), 300 m (liquids)
SoftwareHorizon MB, FTSW100
ComplianceFDA 21 CFR Part 11, GMP/GLP-ready, OPC, Modbus TCP
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelTALYS ASP500-OH
Instrument TypeOnline
PrincipleFourier Transform Near-Infrared (FT-NIR) Spectroscopy
Wavelength Range3800–14000 cm⁻¹
Detector OptionsInGaAs 2.1 (4550–10500 cm⁻¹), InGaAs 2.1 TE-cooled (4750–10500 cm⁻¹), InGaAs 2.6 (4000–10000 cm⁻¹)
Light SourceQuartz Halogen Lamp with Electronic Stabilization
Laser ReferenceSolid-State Laser
Spectral Resolution (Adjustable)1–64 cm⁻¹
Wavenumber Reproducibility (@7300 cm⁻¹)<0.006 cm⁻¹
Wavenumber Accuracy (@7300 cm⁻¹)<0.06 cm⁻¹
Sampling ModesTransmission, Diffuse Reflectance, Transflectance
Data Sampling IntervalBetter than 0.7 cm⁻¹
Software SuiteHorizon MB, Quantify, PLSPlus, PLS-IQ, Unscrambler
Communication ProtocolsModbus TCP (Ethernet), RS232/RS485 (via converter), OPC DA (Ethernet), CANopen (via USB-to-CAN adapter)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGLA132
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelMB3000
Instrument TypeLaboratory FTIR Spectrometer
Wavenumber Range490–8500 cm⁻¹
ResolutionAdjustable from 1 to 64 cm⁻¹ (2× step increments)
Signal-to-Noise Ratio50,000:1 (60 s acquisition, 4 cm⁻¹ resolution)
DetectorDTGS
Beam SplitterZnSe
InterferometerDual-pivot Michelson with high-throughput optical design
Laser SourceSolid-state laser
ADC Resolution24-bit
Wavenumber Accuracy< 0.01 cm⁻¹ (@1918 cm⁻¹)
Wavenumber Repeatability< 0.001 cm⁻¹ (@1918 cm⁻¹)
Short-term Stability< 0.09 %
Temperature Stability< 1 %/°C
Power Consumption65 W
Dimensions435 × 280 × 372 mm
Weight24 kg
ComplianceCSA, RoHS, CE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelMBGAS-3000
Instrument TypeMulti-component FTIR Flue Gas Analyzer
Measurement PrincipleFourier Transform Infrared Spectroscopy
Max. Simultaneous Components25
Accuracy (Relative Error)≤4% FS
Repeatability≤2% RSD
Response Time (T90)≤80 s
Long-term Stability (7-day drift)≤4% FS
Operating ModeHot/Wet Sampling
Detection of Water-Soluble GasesHCl, HF, NH₃, SO₂, NO, NO₂, CO, CO₂, CH₄, N₂O, etc.
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelMBGAS-3000
Instrument TypeMulti-component FTIR Flue Gas Analyzer
Measurement PrincipleFourier Transform Infrared Spectroscopy
Max. Simultaneous Components25
Accuracy (Linearity & Span Error)≤ ±3% of full scale
Repeatability≤ 2% RSD
Response Time (T90)≤ 90 s
Long-term Stability (7-day drift)≤ 3% of full scale
Operating ModeHot/Wet Sampling
Optical Resolution≤ 0.5 cm⁻¹
Laser Source Lifetime≥ 10 years
ComplianceDesigned for EN 15267-3, EN 14181, ISO 12039, and US EPA Methods 320 & OTM-12
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginUSA
ModelPGC5000
Detection PrinciplesGas Chromatography with Thermal Conductivity (TCD), Flame Ionization (FID), and Flame Photometric (FPD) Detection
Column Oven ConfigurationsDual Intelligent Isothermal Zones (PGC5000B & PGC5000C)
Interface10.4″ SVGA Touchscreen HMI, Redundant Ethernet, USB, MODBUS RTU/TCP, Analog/Digital I/O
ComplianceDesigned for SIL2-capable system integration per IEC 61511, compatible with FDA 21 CFR Part 11 audit trail requirements via optional software configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelMB3600-PH
Instrument TypeLaboratory FT-NIR Spectrometer
PrincipleFourier Transform
Spectral Range3800–14000 cm⁻¹
Spectral ResolutionAdjustable from 1 to 64 cm⁻¹ (step size: 2 cm⁻¹), nominal resolution < 0.7 cm⁻¹
Signal Sampling24-bit ADC
SNR (60 s, 16 cm⁻¹, peak response)>100,000:1 (DTGS), >600,000:1 (Extended InGaAs)
Frequency Accuracy (@ 7300 cm⁻¹)< 0.06 cm⁻¹
Frequency Reproducibility (@ 7300 cm⁻¹)< 0.006 cm⁻¹
Absorbance Reproducibility (methanol reference)< 0.002 AU
Short-term Stability (@ 8000 cm⁻¹)< 0.09 %
Temperature Stability (@ 8000 cm⁻¹)< 1 %/°C
Sampling ModesTransmission, Diffuse Reflectance, Fiber-Optic Probe
SoftwareHorizon MB Chemometrics Suite
Regulatory Compliance21 CFR Part 11, cGMP IQ/OQ Protocols Included
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelRVP4500 Series
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGLA133
Detection Gases & RangesCH₄ (0–100 ppm standard
Response Time2.5 Hz (1/e)
Power Consumption<35 W
Weight<3 kg
Measurement RateUp to 10 Hz
TechnologyOff-Axis Integrated Cavity Output Spectroscopy (OA-ICOS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelGLA451-N2OI3
Measurement TargetsN₂O, δ¹⁵N, δ¹⁵Nα, δ¹⁵Nβ, δ¹⁸O, δ¹⁷O*
Detection PrincipleOff-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) with Quantum Cascade Laser
Dynamic Range>20× ambient environmental concentration
Measurement FrequencyUp to 10 Hz (high-flow mode)
Sample IntroductionAutomated gas sampler or manual injection
Internal Temperature ControlYes
Data StorageOnboard computer with long-term archival capability
Output InterfacesAnalog + RS232 digital
Software IncludedInstrument control, real-time diagnostics, isotope ratio calculation and time-series analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelMB3600-CH80
Instrument TypeLaboratory FT-NIR Spectrometer
PrincipleFourier Transform Near-Infrared (FT-NIR)
Wavelength Range3800–14000 cm⁻¹
Data Sampling Interval< 0.7 cm⁻¹
Measurement ModeTransmission
Chemometrics SoftwareHorizon MB
Sample ThroughputNon-destructive, sub-10-second analysis per PET container
Calibration BasisPre-installed quantitative models derived from >150 real-world PET bottle measurements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGLA331-GGA
PriceUpon Request
Measured Gases & RangesCH₄ (0–100 ppm), CO₂ (0–20,000 ppm), H₂O (0–30,000 ppm)
Measurement SpeedUp to 10 Hz (GGA configuration)
CH₄ Precision (1σ, 1 s / 10 s / 100 s)0.6 ppb / 0.2 ppb / 0.1 ppb
CO₂ Precision (1σ, 1 s / 10 s / 100 s)150 ppb / 50 ppb / 20 ppb
H₂O Precision (1σ, 1 s / 10 s / 100 s)150 ppm / 50 ppm / 17 ppm
Maximum Drift (15-min avg, STP, 24 h)CH₄ < 3 ppb, CO₂ < 0.2 ppm
Flow Response Time (1/e)<10 s (standard), 0.1 s (with optional ACC-DS35 dry scroll pump)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMR-i
PriceUSD 2,000,000
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDRS2170
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelGLA351-N2OCM
Detection Gases & RangesN₂O (0–4 ppm, extended to 40 ppm), CO (0–4 ppm, extended to 40 ppm), H₂O (0–30,000 ppm, <99% RH, non-condensing)
Accuracy (1σ, 1 s / 10 s / 100 s)N₂O: 0.1 / 0.04 / 0.02 ppb
CO0.2 / 0.06 / 0.03 ppb
H₂O50 / 20 / 10 ppm
Max Drift (24 h, STP, 15-min avg)N₂O <1 ppb, CO <1 ppb
Measurement Rate0.01–1 Hz (standard), up to 10 Hz with high-flow option
Flow Response Time<12 s (1/e), <10 s with high-flow option
Data OutputsEthernet, Wi-Fi, USB, RS-232
Power110/240 VAC, 50/60 Hz
Dimensions50 × 48 × 86 cm (H×W×L)
Weight68 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPGC2009
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGLA132
PriceUpon Request
Accuracy< 1% uncertainty (uncalibrated, 5–45 °C)
Measured Gases & RangesCH₄ (0.01–100 ppm), CO₂ (200–20,000 ppm), NH₃ (1–10,000 ppb), H₂O (500–30,000 ppm)
Detection PrincipleFourth-Generation Cavity-Enhanced Absorption Spectroscopy (CEAS)
Power Consumption< 70 W
Warm-up Time< 2 min
Data Output Rate0.01–1 Hz (user-selectable)
Operating Temperature5–45 °C
Sample Temperature Range−10–50 °C
Relative Humidity0–98% RH (non-condensing)
Dimensions47 × 35.6 × 17.8 cm (18.5″ × 14″ × 7″)
Weight17 kg
ComplianceCE, RoHS, FCC Class A
Data StorageInternal Linux-based SSD with indefinite logging
Remote AccessWeb-based GUI via Ethernet (HTTPS), full instrument control and diagnostics
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeDistributor
Origin CategoryImported
ModelAnalyzeIT Wet Process Analyzer
Price RangeUSD 140,000 – 280,000 (based on CIF terms)
Instrument PrincipleFourier Transform Near-Infrared (FT-NIR) Spectroscopy
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelEL3000
Measurement PrincipleNon-Dispersive Infrared (NDIR) Spectroscopy
Accuracy≤ 1% of full scale
CO₂ Measurement Range0–5 ppm to 95–100 vol%
Response Time (T₉₀)2.5 s
Repeatability≤ 0.5% of full scale
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelFTPA2000-PH40
Instrument TypeOnline
PrincipleFourier Transform (FT)
Wavelength Range3800–14000 cm⁻¹
Spectral Sampling Interval< 0.7 cm⁻¹
Measurement ModeDiffuse Reflectance
Chemometrics SoftwareFTSW100, Horizon MB
Optical Path Difference (OPD) Scan Speed1 cm/s
Resolution Options1–128 cm⁻¹ (in powers of two)
Wavenumber Repeatability0.002 cm⁻¹ RMS @ 7300 cm⁻¹
Wavenumber Reproducibility0.04 cm⁻¹ RMS @ 7300 cm⁻¹
Absorbance Linearity±0.1% of peak response
SNR (1 scan, 16 cm⁻¹, room temp)≥15,000:1 (extended InGaAs detector)
Long-term Spectral Stability≤2%/°C drift (4000–10000 cm⁻¹)
Beam Splitter MaterialBK7 optical glass
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginUSA
ModelLGR H2S/NH3
Measurement PrincipleCavity Ring-Down Spectroscopy (CRDS)
Detection Limits (1σ, 1 s)NH₃: 1.5 ppb, H₂S: 30 ppb
Measurement RangesNH₃: 2–10,000 ppb (operational up to 200 ppm), H₂S: 30 ppb–50 ppm (operational up to 1,000 ppm), H₂O: 100–70,000 ppm (condensation-free)
Response Time<1 s (T₉₀)
Power Consumption≤60 W
Weight15 kg
Power OptionsAC 100–240 V or DC 12–28 V
Environmental Operating Range−10 to +45 °C, 0–95% RH (non-condensing)
ComplianceDesigned for field-deployable GLP-compliant operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMB3600-HP10
Instrument TypeLaboratory
PrincipleFourier Transform Near-Infrared (FT-NIR) Spectroscopy
Wavelength Range3800–14000 cm⁻¹
Data Sampling Interval< 0.7 cm⁻¹
Measurement ModeTransmission
Chemometrics SoftwareHorizon MB