| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC100 Series |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Oven Temperature Range | +5–450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cooling Rate | 300–50 °C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–700 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| DID Operating Temp | 30–45 °C |
| Ambient Temp Requirement | 10–30 °C |
| Response Time (90%) | 0.5 s |
| Warm-up Time | 60 min |
| Display | 6.5″ color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity helium (He, N6.0), 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 300 kPa |
| Electronic Gas Control | Input 5–10 bar, output control 0–5 bar |
| Output Signal | 0–1 V analog |
| Communication | 4–20 mA, Profibus, Modbus RTU, RS-485 via TrendVision PLUS |
| Power Supply | 220 V AC |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack, 5U) |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM 1000 DID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Dedicated to High-Purity Hydrogen Analysis |
| Temperature Control Range | +5 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (0.1 °C increments) |
| Cool-down Time | ~5 min (300 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–700 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–700 kPa |
| Injector Total Flow Setpoint Range | 10–500 mL/min |
| Detector | Helium Ionization Detector (DID) |
| DID Measurement Range | ppb to % level |
| DID Accuracy | ±1% of full-scale reading |
| DID Operating Temperature | 30–45 °C |
| Ambient Operating Temperature | 10–30 °C |
| DID Response Time (90%) | 0.5 s |
| DID Warm-up Time | 60 min |
| Display | 6.5″ color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity helium (He, N6.0), 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 300 kPa (3 bar) |
| Electronic Gas Control | 5–10 bar input → 0–5 bar regulated output |
| Standard Fittings | 1/8″ stainless steel Swagelok® and VCR |
| Output Signal | 0–1 V analog |
| Alarm Outputs | Detector, system, flow, maintenance, temperature, pressure |
| Data Interface | TrendVision PLUS with 4–20 mA, Profibus, Modbus, RS-485 |
| Power Supply | 220 V AC |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack, 5U) |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaPRO9000 |
| Repeatability | ±0.1% |
| Detection Limit | 1 ppb |
| Detector Type | Helium Discharge Ionization Detector (DID) |
| Column Oven Temperature Range | Ambient to 450 °C with Independent Per-Column Thermal Control |
| Carrier Gas Requirement | Ultra-High-Purity Helium (99.999%) |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM 1000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Impurity Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Temperature Stability | < ±0.05 °C/h (after 30 min warm-up) |
| Cooling Rate | 300 °C to 50 °C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Max Temperature | 300 °C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC 600DID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity (UHP) Gas Analysis |
| Oven Temperature Range | 5°C above ambient to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increments) |
| Oven Cool-Down | 300°C to 50°C in ≤5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Maximum Temperature | 450°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ECO Physics nCLD 822 |
| Pricing | Upon Request |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM1000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Impurity Analysis |
| Oven Temperature Range | 4°C to 450°C |
| Temperature Stability | < ±0.05°C/h (after 30 min warm-up) |
| Cooling Rate | 300°C → 50°C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Maximum Temperature | 300°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NovaCHROM2000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal for Ultra-High-Purity Gas Analysis |
| Temperature Control Range | 5°C above ambient to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increment) |
| Cooling Rate | 1°C/sec (typical, from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–40 mL/min (EPC-controlled) |
| Carrier Gas Pressure Range & Control | 0–600 psi (EPC-controlled) |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–200 psi |
| Injector Total Flow Setting Range | 100–300 mL/min |
| Detector Options | ADD (Argon Discharge Detector), DID (Dielectric Barrier Discharge Ionization Detector), TCD, FID, FPD |
| Detection Limit | Sub-ppb to ppm level |
| Accuracy | ±1% of full scale |
| Response Time | 0.5 s (to 90% of final signal) |
| Warm-up Time | ≤60 min |
| Display | 6.5" color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity argon (Ar, N6.0, 99.9999% purity), flow 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 3 bar (300 kPa) |
| Electronic Pressure Control Input | 5–10 bar |
| Output Control Range | 0–5 bar |
| Standard Fittings | 1/8" stainless steel Swagelok® and VCR |
| Analog Output | 0–1 V (detector, system status, flow, maintenance, temperature, pressure) |
| Data Interface | TrendVision PLUS with 4–20 mA, Profibus, Modbus RTU, and RS-485 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (Rack Mount) | 19" (483 mm) W × 5U (219 mm) H × 22" (564 mm) D |
| Dimensions (Free-Standing) | H=900 mm, W=600 mm, D=400 mm |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC23 THC Analyzer |
| Detection Principle | Catalytic Combustion + Methane Conversion + Flame Ionization Detection (FID) |
| Display | 5.7″ QVGA Touchscreen |
| Calibration | Automated Zero/Range Calibration via Internal Solenoid Valves |
| Flow Control | Digital Electronic Mass Flow Controllers (MFCs) |
| Sample Flow Monitoring | Real-time Digital Flow Visualization & Alarm |
| Output Signals | 2 × Isolated, Passive 4–20 mA Outputs |
| Communication | RS-232 Serial Interface |
| Range Selection | 3 Auto-ranging Full-Scale Ranges |
| Compliance Support | Designed for ISO 8573-5, ASTM D6245, EPA Method 25A, and EN 15409-compliant installations |
| Safety Certification | ATEX / IECEx Zone 2 (optional), CE Marked |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaSTREAM 6000 |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–20,000 ppm C₁–C₁₀ (as methane or propane equivalent) |
| Minimum Detectable Level | <10 ppb |
| Linearity Error | ≤±1% F.S. |
| Repeatability | ±30 ppb |
| Span Drift | ±30 ppb (24 h) |
| Response Time (T₉₀) | ≤30 s |
| Operating Temperature | 10–40 °C |
| Display | 6.5-inch TFT LCD touchscreen |
| Data Storage | 10,000 measurement records |
| Communication Interface | RS232 |
| Dimensions (W×H×D) | 483 mm × 450 mm × 400 mm (19″ rack-mount compatible) |
| Alarm Outputs | Dry-contact relays for high/low concentration, system fault, sample gas interruption, zero/span gas loss, and flame-out detection |
| Built-in Diagnostics | 20 standardized fault codes |
| Auto-Calibration | Motorized solenoid valves for automated zero/span calibration cycles |
| Flow Control | Integrated electronic mass flow controllers (MFCs) for sample, hydrogen, air, and zero/span gases |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC50 |
| Detection Principle | Thermal Conductivity Detection (TCD) |
| Configuration | Online Fixed-Installation Analyzer |
| Response Time (t90) | <30 s |
| Repeatability | ±0.5% FS for H₂, He, CO₂, and other binary gas mixtures or high-purity gases |
| Display | 5.7″ QVGA LCD with real-time status, alarm, diagnostic, and measurement readouts |
| Flow Measurement | Integrated high-accuracy mass flow sensor (displayed in real time) |
| Detector Design | Temperature-controlled TCD with adjustable setpoint, housed in thermally stabilized metal enclosure |
| Zero Reference | Electromechanically actuated solenoid valve for periodic zero-gas introduction |
| Drift Stability | <1% full-scale drift over 24 h at constant ambient and sample conditions |
| Sample Compatibility | Binary gas mixtures and ultra-high-purity gases (e.g., N₂/H₂, Ar/He, O₂/CO₂, air/N₂) |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | MAP-PAK Combi |
| Measurement Range | 0.1–100% O₂ and CO₂ |
| Accuracy | ±1% of reading |
| Response Time | <10 s |
| Data Storage Capacity | Up to 5,000 records |
| Display | Backlit LCD |
| Power | Rechargeable battery (4 units) + AC adapter |
| Compliance | CE-marked, ISO 9001-manufactured instrumentation |
| Software | MP Download Software (Windows-compatible) |
| Optional Accessory | Portable thermal printer |
| Language Support | Multilingual UI (English, French, German, Spanish, Italian, Chinese) |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NC1000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity Semiconductor Gas Analysis |
| Temperature Control Range | 0–300 °C |
| Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cool-down Time | ~5 min (300 °C → 50 °C) |
| Carrier Gas Flow Range | 0–900 mL/min |
| Carrier Gas Pressure Range | 0–700 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–700 kPa |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Detector | Pulsed Helium Discharge Ionization Detector (DID) |
| Detection Range | ppb to % level |
| Accuracy | ±1% of full scale |
| Response Time (90%) | 0.5 s |
| Warm-up Time | 60 min |
| Display | 6.5″ color LCD with resistive touchscreen |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack-mount, 5U) |
| Weight | 25 kg |
| Carrier Gas | Ultra-high-purity helium (N6.0, 20–60 mL/min) |
| Sample Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Dry, oil-free air at 300 kPa |
| Electronic Pressure/Flow Control | 0–5 bar output (5–10 bar input) |
| Output Signals | 0–1 V analog |
| Compliance | Designed for ASTM D7527, ISO 8573-5, IEC 61511, and aligned with USP <621>, FDA 21 CFR Part 11 data integrity requirements for electronic records |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaSTREAM 6000 |
| Linear Error | ≤±1% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | ≤±1% F.S./6 months |
| Response Time | ≤5 s (T90) |
| Detection Limit | <10 ppb |
| Power Consumption | <100 W |
| Minimum Inlet Pressure | 10 kPa |
| Display | 6.5-inch color LCD touchscreen |
| Output Interfaces | 2 × 4–20 mA, 1 × mV, VGA, USB, Ethernet, RS-232, RS-485 |
| Data Storage | Up to 24 months internally |
| Calibration | Automated with audit-trail logging |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECO nCLD63 |
| Price Range | USD 14,000 – 42,000 |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC STREAM 6000 |
| Detection Principle | High-Frequency Argon Discharge Detector (HFADD) |
| Measurement Range | 0–1 ppm / 0–10 ppm / 0–100 ppm |
| LOD | 10 ppb |
| Accuracy | ±1% of full scale |
| Zero Drift | <1% FS / Span Drift: <1% FS |
| Response Time (t₉₀) | 5 s |
| Display | 6.5" industrial-grade touchscreen |
| Signal Outputs | 2 × 4–20 mA, 1 × mV, VGA, USB |
| Communication Options | RS-232 / RS-485 / Ethernet (optional) |
| Alarm Outputs | 7 dry-contact relays (including sample flow monitor) |
| Calibration | Auto-calibration with audit-trail logging |
| Data Storage | Internal non-volatile memory (24-month trend retention) |
| Sample Flow Rate | 5–200 mL/min |
| Inlet Pressure | 10–50 kPa |
| Power | 100–120 VAC / 220–240 VAC, 50/60 Hz |
| Dimensions | 482 mm (W) × 511 mm (D) × 177 mm (H), 4U 19″ rack-mountable |
| Weight | 9 kg |
| Brand | AGC |
|---|---|
| Origin | Switzerland |
| Model | ECO Physics nCLD 844 |
| Measurement Principle | Gas-Phase Chemiluminescence Detection |
| Detection Targets | NO, NO₂, NOₓ, NH₃ (via catalytic conversion) |
| Measurement Range | 0.5–500 ppm (4 programmable ranges) |
| Response Time (T90) | < 1 s |
| Minimum Detectable Concentration | 0.025 ppm |
| Sample Flow Rate | 1.2 L/min |
| Reaction Chamber Temperature | Up to 190 °C (heated sample line) |
| Ozone Generator | High-voltage, high-output |
| O₃ Decomposition | Integrated thermal catalytic decomposer (no consumables) |
| Compliance | Designed for EN 14181, ISO 11665, EPA Method 7E, ASTM D5158, and GLP/GMP-aligned data integrity workflows |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NP9000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Temperature Control Range | +5°C to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increments) |
| Cooling Rate | 300°C to 50°C in ~5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–700 kPa |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Explosion Protection Rating | Ex pxb IIB+H2 T3 Gb |
| Column Oven Configuration | Multiple Independent Temperature-Controlled Ovens |
| Display | 12" Industrial Capacitive Touchscreen |
| Data Output Interfaces | 4–20 mA, Profibus, Modbus, Ethernet |
| Detector Options | DID, FID, TCD, FPD, PID, ADD |
| Column Types Supported | Packed, Micro-packed, Capillary |
| Valve Types | Stainless Steel / Hastelloy VICI Valco (4-, 6-, 8-, or 10-port) |
| Enclosure Material | Low-Carbon Steel with Front Safety Door |
| Gas Line Fittings | 1/8" Swagelok® or VCR (Hastelloy optional) |
| Operating Ambient Temperature | −10°C to +50°C |