Empowering Scientific Discovery

Aiwa Technology

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginUSA
ModelSR2
Spectral Range185–1100 nm (configuration-dependent)
Detector TypeCCD
Optical Resolution (FWHM)0.56–1.71 nm
Signal-to-Noise Ratio380:1 (single acquisition)
Dynamic Range3400:1 (single acquisition)
Integration Timeas low as 10 µs
Slit Options5, 10, 25, 50, 100, or 200 µm
Thermal StabilityEngineered for low drift across operating temperatures
Inter-unit ConsistencyLow unit-to-unit variation via automated precision manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginUSA
ModelQE65 Pro
Spectral Range200–1100 nm
DetectorBack-Illuminated CCD (Hamamatsu FFT-CCD)
Optical Resolution (FWHM)0.14–7.7 nm
Sensitivity22 e⁻/count (all λ)
Signal-to-Noise Ratio1000:1 (full signal)
Dynamic Range7.5 × 10⁹
Stray Light<0.08% @ 600 nm
CoolingTwo-stage TEC to –15 °C (ΔT = –40 °C below ambient)
Integration Time8 ms – 15 min
SlitInterchangeable SMA905-compatible slit
Grating OptionsIncluding 900 grooves/mm (#H36), blaze 500 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginUSA
ModelOcean ST
Spectral Range185–650 nm (UV-VIS), 350–810 nm (VIS-NIR), 645–1085 nm (NIR)
Optical Resolution (FWHM, 25 µm slit)2.2 nm
Signal-to-Noise Ratio190:1 (single scan @ 10 ms), 2250:1 (1 s averaging, no buffer)
Dynamic Range1000:1 (single scan)
Stray Light< 2.0 AU
Integration Time3.8 ms – 6 s
Scan Rate160 Hz (no buffer)
A/D Resolution14-bit
Thermal Stability0.05 pixel/°C
InterfaceUSB-C + 16-pin Samtec TFM-108-02-L-DH connector
Dimensions42.1 × 40.3 × 26.6 mm
Weight70.4 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginImported
ModelOcean HDX
Spectral Range200–925 nm
Detector TypeCCD
Optical Resolution (FWHM)0.61–0.72 nm (with 10 µm slit)
Signal-to-Noise Ratio400:1
Dynamic Range12,000:1
Stray Light< 0.3% (typical, at 600 nm with 400 nm cutoff filter)
Onboard Storage CapacityUp to 50,000 spectra
Interface OptionsUSB 3.0, Gigabit Ethernet, Wi-Fi (802.11ac), RS-232
Operating Temperature Stability±0.05 nm/°C (wavelength drift)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginUSA
ModelSTS Miniature Fiber Optic Spectrometer
Spectral Range200–1100 nm
Detector TypeCMOS
Optical Resolution (FWHM)1.0–12.0 nm (configurable via slit width)
Signal-to-Noise Ratio>1500:1 (at maximum signal)
Dynamic Range5×10⁹ (system, 10 s integration)
Stray Light≤0.25% at 450 nm
Dimensions40 × 42 × 24 mm
Weight68 g
Integration Time10 µs – 10 s
Dark Noise≤3 counts RMS
Grating600 lines/mm
Input ConnectorSMA 905
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginShanghai, China
ModelHR2000+
Spectral Range200–1100 nm
DetectorSony ILX511B linear CCD array (2048 pixels)
Optical Resolution (FWHM)0.035–6.8 nm
Sensitivity75 photons/count @ 400 nm
Signal-to-Noise Ratio250:1 (full signal)
Dynamic Range2 × 10⁸ (system)
13001 (single acquisition)
Stray Light<0.05% @ 600 nm
A/D Resolution14-bit
Integration Time1 ms – 65 s
Slit Options5, 10, 25, 50, 100, or 200 µm
Grating Options14 UV–NIR gratings including HC-1 for enhanced UV throughput
Optical Designf/4 symmetrical crossed Czerny-Turner (101.6 mm focal length)
InterfaceUSB 2.0 (480 Mbps), RS-232 (115.2 kbaud), or Ethernet via Remora adapter
Trigger Modes4 hardware/software-selectable modes
Digital I/O10 programmable GPIO pins
Analog I/O1 × 13-bit input, 1 × 9-bit output
Dimensions148.6 × 104.8 × 45.1 mm
Weight570 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginUSA
ModelFS1100
Spectral Range300–1100 nm
DetectorCCD
Optical Resolution (FWHM)1.3 nm
Signal-to-Noise Ratio450:1
Dynamic Range8000:1
Stray Light<0.05% at 600 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Insight
OriginUSA
Detector TypeBack-Illuminated CCD
Spectral RangeConfigurable from 185–1100 nm
Resolution18-bit ADC
Peak Quantum Efficiency90%
Signal-to-Noise Ratio1000:1 (full well, single acquisition)
Dynamic Range85,000 (typical, at full well capacity)
Stray Light<0.08% at 600 nm
CoolingThermoelectrically cooled to –15 °C (stabilized ±0.1 °C)
Onboard Memory15,000 spectra buffer
InterfaceUSB 2.0 / USB 3.0 compatible
Slit Options5–200 µm (interchangeable)
Grating OptionsMultiple groove densities and blaze wavelengths available
Internal ShutterOptional for dark current optimization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
ModelMaya2000 Pro
Spectral Range200–1100 nm
Detector TypeBack-Illuminated CCD
Optical Resolution0.07–6.7 nm (slit- and grating-dependent)
Signal-to-Noise Ratio450:1
Dynamic Range~8000:1
Stray Light<0.05% at 600 nm, <0.10% at 435 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelSpectrumTEQ-PL
PricingUpon Request
Spectrometer OptionsQE Pro / QE65 Pro (350–1100 nm) or NIRQuest+ (900–1700 nm / 900–2200 nm)
SNR1000:1 (QE Pro, 100 ms) / 15,000:1 (NIRQuest+, 100 ms)
Optical Resolution (FWHM)2.5 nm (QE Pro) / 3.4–10.8 nm (NIRQuest+)
Dynamic Range85,000:1 (QE Pro, single acquisition) / 15,000:1 (NIRQuest+, single scan)
ADC18-bit (QE Pro) / 16-bit (QE65 Pro, NIRQuest+)
Integrating Sphere Diameter3.3″ (standard), 1.5″ (optional)
Sphere CoatingSpectralon® (PTFE-based, >99% reflectance, 250–2500 nm)
Light SourceHL-3-INT-CAL calibrated halogen lamp (5 W electrical power)
Excitation Source CompatibilityExternal CW or pulsed LEDs/lasers (user-supplied)
Fiber Core1000 µm (quartz, SMA 905, interchangeable)
Source Measure UnitKeithley 2400 or 2450 (for electroluminescent mode)
SoftwareOcean QY v3.x (Windows-based, guided workflow, ASTM E2758-compliant reporting)
Sample EnvironmentGlovebox-compatible (O₂/H₂O < 0.1 ppm), ambient or controlled atmosphere
Measurement ModesAbsolute photoluminescence quantum yield (PLQY), electroluminescence quantum yield (ELQY), spectral radiance, luminance, chromaticity (CIE 1931), dominant wavelength, radiant/photometric flux
RepeatabilityPLQY ±5%, ELQY ±2%, dominant wavelength ±0.5 nm, luminance >98% (Lambertian reference)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Insight
OriginUSA
ModelFLAME-S / FLAME-T
Spectral Range190–1100 nm
Detector TypeCMOS (back-thinned or standard, model-dependent)
Optical Resolution (FWHM)Configurable via slit width and grating selection
SensitivityConfiguration-dependent (e.g., UV-enhanced or NIR-optimized)
Signal-to-Noise Ratio250:1 (full signal, 10 ms integration)
3001 (with on-chip binning)
Dynamic Range8.5 × 10⁷ (system, with 16-bit ADC and multi-integration)
Stray Light<0.05% at 600 nm
Dimensions89.1 × 63.3 × 34.4 mm
Weight265 g
InterfaceUSB 2.0 (micro-B), no external power required
Operating Temperature0–40 °C
Thermal Drift<0.03 nm/°C (typical, with onboard thermal stabilization)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginUSA
ModelUSB4000
Spectral Range190–1100 nm
DetectorToshiba TCD1304AP Linear CCD Array (3648 pixels, 8 µm × 200 µm)
Optical Resolution (FWHM)0.02–8.4 nm (configurable via grating & slit selection)
Sensitivity130 photons/count @ 400 nm
Signal-to-Noise Ratio300:1 (full signal)
Dynamic Range3.4 × 10⁶ (single acquisition)
Stray Light<0.05% @ 600 nm
A/D Conversion16-bit with auto-zero and temperature-compensated dark correction
Integration Time3.8 ms – 10 min
InterfaceUSB 2.0 (480 Mbps), RS-232, SPI, I²C
GPIO8 programmable digital I/O pins
Dimensions89.1 × 63.3 × 34.4 mm
Weight190 g
Operating SystemsWindows, macOS, Linux
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginUSA
ModelHR4 Pro
Spectral Range190 nm – 1100 nm
Detector TypeCCD
Optical Resolution (FWHM)0.42 nm (typical), 0.72 nm (typical)
Sensitivity6 counts/photon
Signal-to-Noise Ratio250:1, 290:1, and 300:1 (full signal, configuration-dependent)
Dynamic Range1500:1, 2000:1, and 2500:1 (integration-time dependent)
Stray Light<0.05% at 600 nm
Configuration OptionsUV-Vis (200–875 nm), Vis-NIR (350–1025 nm), Full Range (200–1100 nm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginUSA
ModelFS1100
Spectral Range300–1100 nm
DetectorCCD array
Optical Resolution (FWHM)1.3 nm
Signal-to-Noise Ratio450:1
Dynamic Range8000:1
Stray Light<0.05% at 600 nm
DisplayMonochrome e-ink screen
BatteryRemovable 4200 mAh Li-ion, >6 h continuous operation
InterfaceAndroid-based acquisition app + Windows-compatible spectral processing software
Data Export Formats.txt, .csv, .m
MountingAdjustable tripod-compatible handle (29–88 cm height range)
Integrated featuresMotorized shutter, auto-exposure, embedded image/audio annotation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginUSA
ModelSpectrumTEQ-EL
Spectral Range350–1100 nm
DetectorCCD
Optical Resolution2.5 nm (FWHM)
Sensitivity0.14–7.7 nm (wavelength-dependent responsivity)
Signal-to-Noise Ratio1000:1
Dynamic Range85,000:1 (typical, single acquisition, QEPro)
Stray Light<0.08% at 600 nm
Integrating Sphere Diameter3.3" or 1.5"
Sphere CoatingSpectralon®
Source MeterKeithley 2400
Fiber Core Diameter1000 µm (interchangeable)
Calibration StandardHL-3-INT-CAL 2π geometry, 50 lm, 5 W
AD Resolution18-bit (QEPro), 16-bit (QE65Pro)
SoftwareSpectrumTEQ-EL dedicated application
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
ModelOcean-FX
Spectral Range200–1100 nm
Optical Resolution (FWHM)0.8 nm (with 600 l/mm grating & 5 µm slit)
DetectorHamamatsu S11639 CMOS
SensitivityOptimized for 200–1025 nm with 25 µm slit
Signal-to-Noise Ratio (SNR, single scan)~270:1
Dynamic Range (single scan)~6400:1
Stray Light<0.08% at 600 nm
Minimum Integration Time10 µs
Onboard Buffer50,000 spectra with timestamping
Scan RateUp to 4500 scans/s (system-dependent)
Slit Options5, 10, 50, 100, or 200 µm
Input ConnectorSMA 905 or FC
Thermal Drift0.11 pixels/°C
Communication InterfacesGigabit Ethernet, Wi-Fi 802.11n, USB 3.0
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0