| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE 9100 |
| Pricing | Available Upon Request |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dansensor ISM-3 |
| Measurement Range | 1 ppm – 100 % O₂ (std. 0–20.9 %) |
| Accuracy | ±1% of reading |
| Sensor Type | Ceramic Solid-State Electrochemical |
| Response Time | <60 s (t₉₀) |
| Flow Rate | 125 mL/min |
| Warm-up Time | 10 min (operational), 20 min (full stabilization) |
| Calibration Interval | 12 months |
| Output Signal | 4–20 mA (standard), optional 0–10 V |
| Alarm Outputs | 2 programmable O₂ alarms + system fault alarm (max. 48 V, 1 A, SPST configurable) |
| Power Supply | 230 VAC ±10% / 115 VAC ±10%, 50–60 Hz |
| Enclosure Material | Stainless steel (IP65-rated housing) |
| Dimensions (H×W×D) | 125 × 185 × 125 mm (ISM-3i), 125 × 185 × 160 mm (ISM-3x w/ integrated display) |
| Weight | 3.7 kg (ISM-3i), 3.8 kg (ISM-3x) |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | PERMATRAN-C® 4/30 |
| Detection Limit | 0.5 cm³/(m²·day) |
| Measurement Principle | Modulated Infrared Spectroscopy |
| Compliance | ASTM F2476 |
| Test Chamber | Dual independent horizontal chambers with interchangeable fixtures |
| Temperature Control | Automated, ±0.1 °C stability |
| Flow Control | Fully automated mass flow regulation |
| Throughput | High—real-time CO₂ concentration monitoring enables rapid equilibrium detection |
| Sample Types | Films, laminates, pouches, trays, bottles, and rigid containers |
| Range | 0.5–8,000 cm³/(m²·day), extendable to ~72,000 cm³/(m²·day) via area reduction factor (×9) |
| Brand | Mocon |
|---|---|
| Model | Dansensor LeakMatic II |
| Origin | Denmark |
| Type | Online Non-Destructive CO₂-Based Leak Detection System for Modified Atmosphere Packaging (MAP) |
| Max. Test Speed | 4 cartons/min |
| Max. Package Dimensions (with fill) | 330 × 610 × 300 mm (L×W×H) |
| Sensor Type | Optical CO₂ Sensor |
| Test Pressure Range | Down to 300 mbar absolute |
| Warm-up Time | 1 min (cold start), 20 sec (from standby) |
| Number of Programmable Test Methods | 16 |
| Interface | Dual RS232 ports, Relay outputs (≤48 V/1 A) |
| Power Supply | 400 VAC |
| Weight | ~450 kg |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-013 |
| Price | Upon Request |
| Detection Range | 20 ppm |
| Minimum Detectable Quantity (MDQ) | 1.5 ppb |
| T90 Response Time | < 4 s (typical) |
| Housing Color | Yellow |
| Certification | UL, CAN/CSA, ATEX, IECEx |
| Sensor Architecture | 4-Series Compatible |
| Lamp Type | Long-Life UV Lamp (10.6 eV) |
| Internal Regulation | Dual Linear Voltage Regulators |
| Filtration | Dual-Stage Particle Filter |
| Humidity Compensation | Electrode-Based Suppression |
| Thermal Drift | Negligible |
| Maintenance | Field-Serviceable & Cleanable |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optech-O2 P |
| Power Supply | USB-powered (2.5 W) |
| Operating Temperature | 5–40 °C (Headspace Mode), 10–35 °C (Dissolved O₂ Mode) |
| Measurement Principle | Fluorescence-based Confocal Optical Sensing |
| Detection Range (Headspace) | 0.050%–25% O₂ (500 ppm–250,000 ppm) |
| Detection Range (ImPULSE™ Adhesive Sensor) | 0.001%–25% O₂ (10 ppm–250,000 ppm) |
| Repeatability (Needle Probe, 0–150 mmHg) | ±0.100% O₂ or ±5% of reading (whichever is greater) |
| Repeatability (Needle Probe, 150–1000 mmHg) | ±0.015% O₂ or ±2% of reading (whichever is greater) |
| Repeatability (ImPULSE™ Sensor) | ±0.015% O₂ or ±3% of reading (whichever is greater) |
| Probe Dimensions (w/ Needle) | 4.83 × 3.30 × 15.24 cm (H×W×D) |
| Probe Dimensions (w/o Needle) | 4.83 × 3.30 × 22.86 cm (H×W×D) |
| Preheat Time | 20 min |
| Compliance | CE, CSA, UL certified |
| Pressure Compensation | Integrated for needle-based measurements |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckPoint 4 |
| Origin | Denmark |
| Detection Gases | O₂ and CO₂ (selectable single or dual) |
| Measurement Principle | Electrochemical (O₂), Infrared (CO₂) |
| Portability | Handheld, battery-powered |
| Interface | Capacitive touchscreen with 10 language options |
| Compliance | Designed for ISO 22000, HACCP, and GMP-aligned quality control environments |
| Power | Rechargeable Li-ion battery with rugged charging port |
| Accessories | Standard low-cost hypodermic needle probe (22G), optional protective boot |
| Auto-shutdown | Yes, energy-saving mode |
| Gas flow alarm | Visual and audible alert |
| Certifications | CE, RoHS, FDA-compliant design (non-invasive testing per 21 CFR Part 11 data integrity guidelines) |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W 3/38 H |
| Application | PV Backsheet & Encapsulant Barrier Testing |
| Compliance | ASTM F1249 |
| Detection Range | 0.05–200 g/(m²·day) |
| Sensor Type | Patented Modulated Infrared Detector |
| Chamber Configuration | Dual removable test cells (4 samples per run) |
| Control System | Fully automated temperature, RH, and carrier gas flow |
| Sealing Technology | TruSeal nitrogen purge ring |
| Measurement Principle | Modulated IR detection of water vapor in carrier gas stream |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MultiCheck 2 |
| Price Range | USD 13,500 – 27,000 |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | eV-NXT 045-111 |
| Detection Range | 0–2,000 ppm |
| LOD | 100 ppb |
| T90 Response Time | < 3.5 s |
| Typical Sensitivity | 2.4 mV/ppm |
| Measurement Condition | 100 ppm |
| Operating Voltage | Low-Voltage DC |
| Power Consumption | Ultra-Low |
| Intrinsic Safety Rating | Certified |
| Onboard Fault Detection | Yes |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE piD-TECH eVx |
| Pricing | Available Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE PID-TECH eV-NXT |
| Pricing | Available Upon Request |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | Lippke 5000 |
| Origin | Denmark |
| Application | Medical, Pharmaceutical & Food Packaging Seal Integrity Testing |
| Test Principles | Pressure Decay, Burst, Creep, Bubble, and Combined Testing |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Max Test Volume | 90 L |
| Pressure Range | 10–5000 mbar |
| Resolution | 0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar) |
| Accuracy | ±0.5 mbar or ±1% of reading (whichever is greater) |
| Test Duration | 1–500 s |
| Data Storage | >1,000,000 records |
| Interface | USB 2.0 (Host & Device), RJ-45 Ethernet |
| Power | 90–264 VAC, 47–63 Hz, ≤50 W |
| Dimensions | 284 × 236.5 × 185 mm |
| Weight | 3.4 kg |
| IP Rating | IP20 |
| Operating Temp | +2 °C to +25 °C |
| Humidity | 10–90% RH (non-condensing) |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-114 |
| Detection Range | 4 ppm |
| LOD | 0.5 ppb |
| T90 | < 6.5 s |
| Typical Sensitivity | 545 mV/ppm |
| Measurement Condition | 1 ppm |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Baseline 9200 |
| Pricing | Upon Request |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckMate 4 SV |
| Origin | Denmark |
| Gas Measurement | O₂ or O₂ + CO₂ |
| Principle | Zirconia (O₂), Electrochemical (O₂), Dual-Beam Infrared (CO₂), Optical Fluorescence (O₂) |
| Sampling Method | Non-invasive optical probe or minimally invasive needle-penetration |
| Minimum Sample Volume | None |
| Resolution | 0.001% |
| Accuracy | ±0.02% |
| Compliance | Designed for ISO 8573-1, ASTM F2714, USP <1207>, FDA 21 CFR Part 11–ready software architecture |
| User Interface | Multi-language capacitive touchscreen (10 languages) |
| Data Management | On-device storage with timestamped audit trail, optional PC-based Dansensor Insight™ software for multi-line monitoring and GLP/GMP-compliant reporting |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | eV-NXT 045-110 |
| Price | Upon Request |
| Detection Range | 0–10,000 ppm |
| LOD | 500 ppb |
| T90 Response Time | < 3.5 s |
| Typical Sensitivity | 0.6 mV/ppm |
| Calibration Gas | 2000 ppm Isobutylene (standard) |
| Operating Temperature | –20 °C to +50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Supply | 3.3 V DC nominal |
| Power Consumption | < 80 mW (active mode) |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | Ox-TRAN® 2/48 |
| Compliance | ASTM D3985 |
| Sensor Technology | Coulometric (Coulox®) |
| Test Chambers | 8 (4 conditioning + 4 testing, parallel operation) |
| Humidity & Flow Control | Automated in both conditioning and test chambers |
| Sealing System | TruSeal® integrated |
| Warranty | 4-year sensor warranty |
| Software | Touchscreen GUI with audit trail, user-level access control, and GLP-compliant reporting |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | Lippke 5000 |
| Test Pressure Range | 10–5000 mbar |
| Resolution | 0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar) |
| Accuracy | ±0.5 mbar or ±1% of reading (whichever is greater) |
| Test Volume Capacity | 0–90,000 mL |
| Test Duration | 1–500 s |
| Data Storage | >1,000,000 records |
| Interface | USB 2.0 (Host & Device), RJ-45 Ethernet |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/48 |
| Compliance | ASTM D3985 |
| Sensor Type | Coulometric (Coulox®) |
| Chamber Configuration | 8-chamber (4 conditioning + 4 testing, parallel operation) |
| Humidity & Flow Control | Automated RH and carrier gas flow in both conditioning and test chambers |
| Sealing Technology | TruSeal® integrated seal verification |
| Warranty | 4-year sensor warranty |
| Software | MOCON Permatran-W® v6.x with 21 CFR Part 11 compliance options |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-113 |
| Detection Range | 0–20 ppm |
| LOD | 1.0 ppb |
| T90 | < 6.5 s |
| Typical Sensitivity | 118 mV/ppm |
| Measurement Condition | 10 ppm |
| Operating Voltage | Low-Voltage DC |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® Model 3/34 |
| Test Range (Film) | 0.005–100 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2% |
| Temperature Range | 10–40 °C (±0.2 °C) |
| Humidity Range | 5–90% RH, up to 100% RH |
| Test Chamber | Dual 50 cm² chambers |
| Sample Size (Film) | 10.8 × 10.8 cm |
| Package Capacity | Up to 3 L |
| Compliance | ASTM F1249, ISO 15106-2, JIS K7129, TAPPI T557, GB/T 26253–2010, GB/T 31355–2014, YBB00092003–2015 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PERMATRAN-W® Model 101K |
| Quotation | Upon Request |
| Test Range | 500–100,000 g/m²·day |
| Test Temperature | 20–50 °C with Automatic Temperature Control |
| Atmospheric Pressure Compensation | Standard |
| Flow Rate Compensation | Standard |
| Number of Test Cells | 6 |
| Cell Area | 10 cm² per cell |
| Compliance | ASTM D6701, WSP 001.0.R3 (12) (EDANA & INDA) |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/28 H |
| Detection Range | 0.05–200 cm³/(m²·day) |
| Sensor Type | Patented Coulometric Coulox® Absolute Sensor |
| Test Chambers | 4 Independent Horizontal Dual-Membrane Cells |
| Compliance | ASTM D3985, ISO 15105-2, FDA 21 CFR Part 11 (with optional audit trail software) |
| Temperature Control | Automatic, ±0.1 °C stability |
| Flow Control | Precision Mass Flow Controllers |
| Sealing Method | TruSeal™ Nitrogen Purge Ring |
| Sample Throughput | Up to 4 specimens simultaneously |
| Detection Limit | 0.05 cm³/(m²·day) |
| Response Time | <60 seconds to 90% signal stabilization |