| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dansensor ISM-3 |
| Measurement Range | 1 ppm – 100 % O₂ (std. 0–20.9 %) |
| Accuracy | ±1% of reading |
| Sensor Type | Ceramic Solid-State Electrochemical |
| Response Time | <60 s (t₉₀) |
| Flow Rate | 125 mL/min |
| Warm-up Time | 10 min (operational), 20 min (full stabilization) |
| Calibration Interval | 12 months |
| Output Signal | 4–20 mA (standard), optional 0–10 V |
| Alarm Outputs | 2 programmable O₂ alarms + system fault alarm (max. 48 V, 1 A, SPST configurable) |
| Power Supply | 230 VAC ±10% / 115 VAC ±10%, 50–60 Hz |
| Enclosure Material | Stainless steel (IP65-rated housing) |
| Dimensions (H×W×D) | 125 × 185 × 125 mm (ISM-3i), 125 × 185 × 160 mm (ISM-3x w/ integrated display) |
| Weight | 3.7 kg (ISM-3i), 3.8 kg (ISM-3x) |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | PERMATRAN-C® 4/30 |
| Detection Limit | 0.5 cm³/(m²·day) |
| Measurement Principle | Modulated Infrared Spectroscopy |
| Compliance | ASTM F2476 |
| Test Chamber | Dual independent horizontal chambers with interchangeable fixtures |
| Temperature Control | Automated, ±0.1 °C stability |
| Flow Control | Fully automated mass flow regulation |
| Throughput | High—real-time CO₂ concentration monitoring enables rapid equilibrium detection |
| Sample Types | Films, laminates, pouches, trays, bottles, and rigid containers |
| Range | 0.5–8,000 cm³/(m²·day), extendable to ~72,000 cm³/(m²·day) via area reduction factor (×9) |
| Brand | Mocon |
|---|---|
| Model | Dansensor LeakMatic II |
| Origin | Denmark |
| Type | Online Non-Destructive CO₂-Based Leak Detection System for Modified Atmosphere Packaging (MAP) |
| Max. Test Speed | 4 cartons/min |
| Max. Package Dimensions (with fill) | 330 × 610 × 300 mm (L×W×H) |
| Sensor Type | Optical CO₂ Sensor |
| Test Pressure Range | Down to 300 mbar absolute |
| Warm-up Time | 1 min (cold start), 20 sec (from standby) |
| Number of Programmable Test Methods | 16 |
| Interface | Dual RS232 ports, Relay outputs (≤48 V/1 A) |
| Power Supply | 400 VAC |
| Weight | ~450 kg |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optech-O2 P |
| Power Supply | USB-powered (2.5 W) |
| Operating Temperature | 5–40 °C (Headspace Mode), 10–35 °C (Dissolved O₂ Mode) |
| Measurement Principle | Fluorescence-based Confocal Optical Sensing |
| Detection Range (Headspace) | 0.050%–25% O₂ (500 ppm–250,000 ppm) |
| Detection Range (ImPULSE™ Adhesive Sensor) | 0.001%–25% O₂ (10 ppm–250,000 ppm) |
| Repeatability (Needle Probe, 0–150 mmHg) | ±0.100% O₂ or ±5% of reading (whichever is greater) |
| Repeatability (Needle Probe, 150–1000 mmHg) | ±0.015% O₂ or ±2% of reading (whichever is greater) |
| Repeatability (ImPULSE™ Sensor) | ±0.015% O₂ or ±3% of reading (whichever is greater) |
| Probe Dimensions (w/ Needle) | 4.83 × 3.30 × 15.24 cm (H×W×D) |
| Probe Dimensions (w/o Needle) | 4.83 × 3.30 × 22.86 cm (H×W×D) |
| Preheat Time | 20 min |
| Compliance | CE, CSA, UL certified |
| Pressure Compensation | Integrated for needle-based measurements |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckPoint 4 |
| Origin | Denmark |
| Detection Gases | O₂ and CO₂ (selectable single or dual) |
| Measurement Principle | Electrochemical (O₂), Infrared (CO₂) |
| Portability | Handheld, battery-powered |
| Interface | Capacitive touchscreen with 10 language options |
| Compliance | Designed for ISO 22000, HACCP, and GMP-aligned quality control environments |
| Power | Rechargeable Li-ion battery with rugged charging port |
| Accessories | Standard low-cost hypodermic needle probe (22G), optional protective boot |
| Auto-shutdown | Yes, energy-saving mode |
| Gas flow alarm | Visual and audible alert |
| Certifications | CE, RoHS, FDA-compliant design (non-invasive testing per 21 CFR Part 11 data integrity guidelines) |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W 3/38 H |
| Application | PV Backsheet & Encapsulant Barrier Testing |
| Compliance | ASTM F1249 |
| Detection Range | 0.05–200 g/(m²·day) |
| Sensor Type | Patented Modulated Infrared Detector |
| Chamber Configuration | Dual removable test cells (4 samples per run) |
| Control System | Fully automated temperature, RH, and carrier gas flow |
| Sealing Technology | TruSeal nitrogen purge ring |
| Measurement Principle | Modulated IR detection of water vapor in carrier gas stream |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MultiCheck 2 |
| Price Range | USD 13,500 – 27,000 |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | Lippke 5000 |
| Origin | Denmark |
| Application | Medical, Pharmaceutical & Food Packaging Seal Integrity Testing |
| Test Principles | Pressure Decay, Burst, Creep, Bubble, and Combined Testing |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Max Test Volume | 90 L |
| Pressure Range | 10–5000 mbar |
| Resolution | 0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar) |
| Accuracy | ±0.5 mbar or ±1% of reading (whichever is greater) |
| Test Duration | 1–500 s |
| Data Storage | >1,000,000 records |
| Interface | USB 2.0 (Host & Device), RJ-45 Ethernet |
| Power | 90–264 VAC, 47–63 Hz, ≤50 W |
| Dimensions | 284 × 236.5 × 185 mm |
| Weight | 3.4 kg |
| IP Rating | IP20 |
| Operating Temp | +2 °C to +25 °C |
| Humidity | 10–90% RH (non-condensing) |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckMate 4 SV |
| Origin | Denmark |
| Gas Measurement | O₂ or O₂ + CO₂ |
| Principle | Zirconia (O₂), Electrochemical (O₂), Dual-Beam Infrared (CO₂), Optical Fluorescence (O₂) |
| Sampling Method | Non-invasive optical probe or minimally invasive needle-penetration |
| Minimum Sample Volume | None |
| Resolution | 0.001% |
| Accuracy | ±0.02% |
| Compliance | Designed for ISO 8573-1, ASTM F2714, USP <1207>, FDA 21 CFR Part 11–ready software architecture |
| User Interface | Multi-language capacitive touchscreen (10 languages) |
| Data Management | On-device storage with timestamped audit trail, optional PC-based Dansensor Insight™ software for multi-line monitoring and GLP/GMP-compliant reporting |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | Ox-TRAN® 2/48 |
| Compliance | ASTM D3985 |
| Sensor Technology | Coulometric (Coulox®) |
| Test Chambers | 8 (4 conditioning + 4 testing, parallel operation) |
| Humidity & Flow Control | Automated in both conditioning and test chambers |
| Sealing System | TruSeal® integrated |
| Warranty | 4-year sensor warranty |
| Software | Touchscreen GUI with audit trail, user-level access control, and GLP-compliant reporting |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | Lippke 5000 |
| Test Pressure Range | 10–5000 mbar |
| Resolution | 0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar) |
| Accuracy | ±0.5 mbar or ±1% of reading (whichever is greater) |
| Test Volume Capacity | 0–90,000 mL |
| Test Duration | 1–500 s |
| Data Storage | >1,000,000 records |
| Interface | USB 2.0 (Host & Device), RJ-45 Ethernet |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/48 |
| Compliance | ASTM D3985 |
| Sensor Type | Coulometric (Coulox®) |
| Chamber Configuration | 8-chamber (4 conditioning + 4 testing, parallel operation) |
| Humidity & Flow Control | Automated RH and carrier gas flow in both conditioning and test chambers |
| Sealing Technology | TruSeal® integrated seal verification |
| Warranty | 4-year sensor warranty |
| Software | MOCON Permatran-W® v6.x with 21 CFR Part 11 compliance options |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® Model 3/34 |
| Test Range (Film) | 0.005–100 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2% |
| Temperature Range | 10–40 °C (±0.2 °C) |
| Humidity Range | 5–90% RH, up to 100% RH |
| Test Chamber | Dual 50 cm² chambers |
| Sample Size (Film) | 10.8 × 10.8 cm |
| Package Capacity | Up to 3 L |
| Compliance | ASTM F1249, ISO 15106-2, JIS K7129, TAPPI T557, GB/T 26253–2010, GB/T 31355–2014, YBB00092003–2015 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PERMATRAN-W® Model 101K |
| Quotation | Upon Request |
| Test Range | 500–100,000 g/m²·day |
| Test Temperature | 20–50 °C with Automatic Temperature Control |
| Atmospheric Pressure Compensation | Standard |
| Flow Rate Compensation | Standard |
| Number of Test Cells | 6 |
| Cell Area | 10 cm² per cell |
| Compliance | ASTM D6701, WSP 001.0.R3 (12) (EDANA & INDA) |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/28 H |
| Detection Range | 0.05–200 cm³/(m²·day) |
| Sensor Type | Patented Coulometric Coulox® Absolute Sensor |
| Test Chambers | 4 Independent Horizontal Dual-Membrane Cells |
| Compliance | ASTM D3985, ISO 15105-2, FDA 21 CFR Part 11 (with optional audit trail software) |
| Temperature Control | Automatic, ±0.1 °C stability |
| Flow Control | Precision Mass Flow Controllers |
| Sealing Method | TruSeal™ Nitrogen Purge Ring |
| Sample Throughput | Up to 4 specimens simultaneously |
| Detection Limit | 0.05 cm³/(m²·day) |
| Response Time | <60 seconds to 90% signal stabilization |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MAP Mix Provectus |
| Price Range | USD 13,500 – 27,000 |
| Gas Types Supported | O₂, N₂, CO₂, Air, Ar (optional) |
| Mixing Configurations | 2-gas or 3-gas |
| Max Total Output Flow | 1500 L/min (3-gas mode) |
| Flow Accuracy | ±2% at ≥50 L/min |
| Input Pressure Range | 2–10 bar |
| Pressure Drop | ≤1 bar at 10 bar inlet |
| Flow Control Range per Gas | 6–500 L/min |
| Operating Temperature | 0–50 °C |
| Display | Touchscreen LCD |
| Connectivity | RS232 ×2, Ethernet (10/100 Mbit, Modbus TCP), USB, 24 VDC I/O |
| Power Supply | 103–132 / 207–264 VAC, 47–63 Hz or 24 VDC |
| Dimensions (H×W×D) | 192 × 230 × 375 mm |
| Weight | 12.0–14.0 kg |
| IP Rating (with optional kit) | IP45 (NEMA 3S) |
| Compliance | CE-marked |
| Predefined Programs | Up to 10 standard gas mixtures |
| Data Logging | Timestamped flow, pressure, mixture ratio, runtime, total consumption |
| Integration | Fully compatible with Dansensor MAP Check 3 gas analyzers |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® 1/50 |
| Test Range | 0.1–100 cm³/m²·day |
| Temperature Range | 5–50 °C (W-type configuration) |
| Humidity Range | 35–90 %RH (standard), up to 100 %RH (W-type) |
| Test Area | 2 chambers × 50 cm² |
| Repeatability | ±0.05 g/m²·day or ±3 % of reading (whichever is greater) |
| RH Sensor Accuracy | ±3 %RH |
| Carrier Gas | Dry nitrogen or oil-free compressed air |
| Compliance | ASTM E398, ISO 15106-1, GB/T 30412–2013 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/12 |
| Test Range (Film) | 0.5–144,000 cc/m²·day |
| Test Range (Container) | 0.0025–720 cc/pkg·day |
| Resolution (Film) | 0.05 cc/m²·day |
| Repeatability | ±0.25 cc/m²·day |
| Temperature Range | 5–50 °C |
| Humidity Range (Film) | 0–90 %RH (±3 %RH) |
| Dual Test Cells | 2 × 50 cm² |
| Sample Size (Film) | 10.8 cm × 10.8 cm |
| Container Capacity | Up to 3 L |
| Compliance | ASTM F2622, ASTM D3985 |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Model | MAP Mix 9001 ME |
| Gas Channels | 2 or 3 |
| Flow Range | 20–400 L/min (40–850 SCFH) |
| Max Output Pressure | 6 bar |
| Input Pressure Range | 5.5–10 bar (varies by configuration) |
| Accuracy | ±2% (at 15–100% flow, 10–90% blend ratio) |
| Housing Material | Stainless Steel |
| Compliance | CE-marked |
| Dimensions (D×H×W) | 420 × 194 × 235 mm |
| Weight | 10–12 kg |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dansensor MAP Check 3 |
| Price Range | USD 6,800 – 13,600 |
| Oxygen Sensor Type | Electrochemical, Range: 0–100% O₂, Accuracy: ±0.01% abs (≤1% O₂), ±1% rel (>1% O₂) |
| CO₂ Sensor Type | Heated Dual-Beam NDIR, Range: 0–100% CO₂, Accuracy: ±0.5% abs, ±1.5% rel |
| Warm-up Time | 10 min (O₂), 8 min (CO₂) |
| Gas Flow Rate | 6–500 L/min |
| Inlet Pressure | 2–10 bar |
| Pressure Drop | 1 bar @ 10 bar inlet |
| Communication Interfaces | 2× RS232C, LAN 10/100 Mbit (Modbus TCP), USB, 4–20 mA / 0–10 V analog outputs, 24 VDC logic I/O |
| Power Supply | 103–132 / 207–264 VAC, auto-ranging, 47–63 Hz |
| Dimensions (H×W×D) | 192 × 230 × 375 mm |
| Weight | 8.5–11.5 kg |
| Enclosure Rating (optional) | IP45 (NEMA 3S) |
| Compliance | CE-marked, RoHS-compliant |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W® 3/38 H |
| Detection Limit | 0.05 g/(m²·day) |
| Measurement Range | 0.05–200 g/(m²·day) |
| Test Chambers | 4 independent horizontal dual-membrane chambers |
| Compliance | ASTM F1249 |
| Sensor Type | Modulated Infrared (Patented MOCON) |
| Environmental Control | Automated temperature, RH, and N₂ flow |
| Sealing Technology | TruSeal nitrogen purge ring |
| Software Interface | Local PC GUI or optional touchscreen HMI |
| Test Mode Options | QC pass/fail mode, reference film validation, triplicate testing |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/40 |
| Test Principle | Coulometric Oxygen Detection |
| Sample Type | Whole Packages & Films |
| Standards Compliance | ASTM D3985, ASTM F1927, ISO 15105-2, JIS K-7126, ASTM F1307, GB/T 31354-2014 |
| Temperature Range | 10–50 °C (±0.2 °C) |
| Humidity Range | 5–90 %RH (±4 %RH) |
| OTR Range (Containers, Air) | 0.00025–1.0 cc/pkg·day |
| Resolution (Containers) | 0.0001 cc/pkg·day |
| Repeatability | ±0.0001 cc/pkg·day |
| Test Duration | 30–60 min |
| Sensor Type | Absolute Coulometric Oxygen Sensor (Faraday-based, calibration-free) |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | LeakPointer 3 |
| Detection Limit | 50 µm |
| Test Cycle Time | 10 s per package |
| Max. Chamber Vacuum | –750 mbar |
| CO₂ Sensor Type | NDIR |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 100–260 VAC, 50/60 Hz |
| Dimensions (open lid) | 617 mm H × 543 mm W × 400 mm D |
| Weight | 20 kg |
| Data Storage Capacity | >1,000,000 test records |
| Compliance | CE-marked |
| Recommended CO₂ Ambient Level | <1500 ppm |
| Calibration Interval | Every 12 months |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | AQUATRAN® Model 3 |
| Test Range (Film) | 0.00005–5 g/m²·day |
| Test Range (Container) | 0.00000025–0.025 g/pkg·day |
| Resolution | 0.00001 g/m²·day |
| Repeatability | ±0.00005 g/m²·day |
| Temperature Range | 5–50 °C (±0.2 °C at 100% RH) |
| Humidity Range (Detector Gas) | 5–90% RH & 100% RH |
| (Carrier Gas) | Dry |
| Test Chamber Options | Dual 50 cm² chambers |
| Compliance | ASTM F3299, ISO 15106-3, GB/T 21529-2008, YBB00092003-2015 |