AMETEK Membrane Solutions

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginUSA
ModelOx-TRAN® 2/48
ComplianceASTM D3985
Sensor TechnologyCoulometric (Coulox®)
Test Chambers8 (4 conditioning + 4 testing, parallel operation)
Humidity & Flow ControlAutomated in both conditioning and test chambers
Sealing SystemTruSeal® integrated
Warranty4-year sensor warranty
SoftwareTouchscreen GUI with audit trail, user-level access control, and GLP-compliant reporting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginUSA
ModelOX-TRAN® 2/48
ComplianceASTM D3985
Sensor TypeCoulometric (Coulox®)
Chamber Configuration8-chamber (4 conditioning + 4 testing, parallel operation)
Humidity & Flow ControlAutomated RH and carrier gas flow in both conditioning and test chambers
Sealing TechnologyTruSeal® integrated seal verification
Warranty4-year sensor warranty
SoftwareMOCON Permatran-W® v6.x with 21 CFR Part 11 compliance options
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginUSA
ModelOX-TRAN® 2/28 H
Detection Range0.05–200 cm³/(m²·day)
Sensor TypePatented Coulometric Coulox® Absolute Sensor
Test Chambers4 Independent Horizontal Dual-Membrane Cells
ComplianceASTM D3985, ISO 15105-2, FDA 21 CFR Part 11 (with optional audit trail software)
Temperature ControlAutomatic, ±0.1 °C stability
Flow ControlPrecision Mass Flow Controllers
Sealing MethodTruSeal™ Nitrogen Purge Ring
Sample ThroughputUp to 4 specimens simultaneously
Detection Limit0.05 cm³/(m²·day)
Response Time<60 seconds to 90% signal stabilization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginUSA
ModelOX-TRAN® Model 2/12
Test Range (Film)0.5–144,000 cc/m²·day
Test Range (Container)0.0025–720 cc/pkg·day
Resolution (Film)0.05 cc/m²·day
Repeatability±0.25 cc/m²·day
Temperature Range5–50 °C
Humidity Range (Film)0–90 %RH (±3 %RH)
Dual Test Cells2 × 50 cm²
Sample Size (Film)10.8 cm × 10.8 cm
Container CapacityUp to 3 L
ComplianceASTM F2622, ASTM D3985
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginUSA
ModelOX-TRAN® 2/40
Test PrincipleCoulometric Oxygen Detection
Sample TypeWhole Packages & Films
Standards ComplianceASTM D3985, ASTM F1927, ISO 15105-2, JIS K-7126, ASTM F1307, GB/T 31354-2014
Temperature Range10–50 °C (±0.2 °C)
Humidity Range5–90 %RH (±4 %RH)
OTR Range (Containers, Air)0.00025–1.0 cc/pkg·day
Resolution (Containers)0.0001 cc/pkg·day
Repeatability±0.0001 cc/pkg·day
Test Duration30–60 min
Sensor TypeAbsolute Coulometric Oxygen Sensor (Faraday-based, calibration-free)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginUSA
ModelOX-TRAN® 2/22 H
Detection PrincipleCoulometric Sensor (ASTM D3985)
ComplianceASTM D3985, ISO 18369-4:2017, GB/T 11417.7–2012
Sensor TypeAbsolute, Zero-Calibration Coulometric Sensor
Measurement RangeUltra-Low to High OTR (O₂)
Application FocusRigid Gas Permeable (RGP) & Soft Hydrogel/Silicone Hydrogel Contact Lens Materials
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginUSA
ModelOX-TRAN® Model 2/22
Standards ComplianceASTM D3985, ASTM F1927, ASTM F1307, ISO 15105-2, GB/T 19789-2005, GB/T 31354-2014, YBB00082003-2015
Test Range (Film)0.0005–200 cm³/(m²·day)
Resolution0.0002 cm³/(m²·day)
Temperature Control10–40 °C (±0.2 °C)
Humidity Control0–90% RH (dual-side independent)
Test ChamberDual 50 cm² chambers (standard), optional 5.64 cm²
Sample FormatFlat films (10.8 × 10.8 cm) or packages (≤3 L)
SensorCoulometric (Coulox®), NIST-traceable, zero-calibration required
AutomationFully automated gas flow, pressure, temperature, and humidity control
Sealing TechnologyTruSeal™ nitrogen curtain sealing
InterfaceIntegrated touchscreen, USB, Ethernet, remote operation via PermNet® Lite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginUSA
ModelOX-TRAN® 2/22
Detection PrincipleCoulometric (COULOX®) Sensor-Based OTR Measurement
ComplianceASTM D3985, ISO 15105-2, FDA 21 CFR Part 11 Ready (with optional software package)
Test ChamberHorizontal, Interchangeable Sealed Test Cell with TruSeal® Dual-Gasket Design
Sample HandlingManual single-sample loading per cycle
Typical OTR Range0.005–10,000 cm³/m²·day·atm (dependent on cell configuration and film barrier level)
Sensor TypeAbsolute coulometric oxygen sensor (zero-calibration required)
Data OutputReal-time OTR curve, permeation onset time, steady-state slope calculation