BrandMOCON
OriginUSA
ModelAQUATRAN-W 3/38 H
ApplicationPV Backsheet & Encapsulant Barrier Testing
ComplianceASTM F1249
Detection Range0.05–200 g/(m²·day)
Sensor TypePatented Modulated Infrared Detector
Chamber ConfigurationDual removable test cells (4 samples per run)
Control SystemFully automated temperature, RH, and carrier gas flow
Sealing TechnologyTruSeal nitrogen purge ring
Measurement PrincipleModulated IR detection of water vapor in carrier gas stream
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMocon
OriginUSA
ModelPERMATRAN-W® Model 3/34
Test Range (Film)0.005–100 g/(m²·day)
Resolution0.001 g/(m²·day)
Repeatability±0.005 g/(m²·day) or ±2%
Temperature Range10–40 °C (±0.2 °C)
Humidity Range5–90% RH, up to 100% RH
Test ChamberDual 50 cm² chambers
Sample Size (Film)10.8 × 10.8 cm
Package CapacityUp to 3 L
ComplianceASTM F1249, ISO 15106-2, JIS K7129, TAPPI T557, GB/T 26253–2010, GB/T 31355–2014, YBB00092003–2015
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelPERMATRAN-W® Model 101K
QuotationUpon Request
Test Range500–100,000 g/m²·day
Test Temperature20–50 °C with Automatic Temperature Control
Atmospheric Pressure CompensationStandard
Flow Rate CompensationStandard
Number of Test Cells6
Cell Area10 cm² per cell
ComplianceASTM D6701, WSP 001.0.R3 (12) (EDANA & INDA)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMocon
OriginUSA
ModelPERMATRAN-W® 1/50
Test Range0.1–100 cm³/m²·day
Temperature Range5–50 °C (W-type configuration)
Humidity Range35–90 %RH (standard), up to 100 %RH (W-type)
Test Area2 chambers × 50 cm²
Repeatability±0.05 g/m²·day or ±3 % of reading (whichever is greater)
RH Sensor Accuracy±3 %RH
Carrier GasDry nitrogen or oil-free compressed air
ComplianceASTM E398, ISO 15106-1, GB/T 30412–2013
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginUSA
ModelAQUATRAN-W® 3/38 H
Detection Limit0.05 g/(m²·day)
Measurement Range0.05–200 g/(m²·day)
Test Chambers4 independent horizontal dual-membrane chambers
ComplianceASTM F1249
Sensor TypeModulated Infrared (Patented MOCON)
Environmental ControlAutomated temperature, RH, and N₂ flow
Sealing TechnologyTruSeal nitrogen purge ring
Software InterfaceLocal PC GUI or optional touchscreen HMI
Test Mode OptionsQC pass/fail mode, reference film validation, triplicate testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMocon
OriginUSA
ModelAQUATRAN® Model 3
Test Range (Film)0.00005–5 g/m²·day
Test Range (Container)0.00000025–0.025 g/pkg·day
Resolution0.00001 g/m²·day
Repeatability±0.00005 g/m²·day
Temperature Range5–50 °C (±0.2 °C at 100% RH)
Humidity Range (Detector Gas)5–90% RH & 100% RH
(Carrier Gas)Dry
Test Chamber OptionsDual 50 cm² chambers
ComplianceASTM F3299, ISO 15106-3, GB/T 21529-2008, YBB00092003-2015
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMocon
OriginUSA
ModelAQUATRAN-W® 3/40
Detection Limit0.000025 g/(pkg·day)
Test Chambers4 independent
Temperature Range10–50 °C
RH Range30–90 % RH
Sensor TypeModulated Infrared (ASTM F1249 compliant)
AutomationFully automated T/RH/flow control, motorized test cartridge exchange, integrated conditioning & purge
InterfaceTouchscreen HMI with real-time parameter monitoring