- All
- Favorite
- Popular
- Most rated
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dansensor ISM-3 |
| Measurement Range | 1 ppm – 100 % O₂ (std. 0–20.9 %) |
| Accuracy | ±1% of reading |
| Sensor Type | Ceramic Solid-State Electrochemical |
| Response Time | <60 s (t₉₀) |
| Flow Rate | 125 mL/min |
| Warm-up Time | 10 min (operational), 20 min (full stabilization) |
| Calibration Interval | 12 months |
| Output Signal | 4–20 mA (standard), optional 0–10 V |
| Alarm Outputs | 2 programmable O₂ alarms + system fault alarm (max. 48 V, 1 A, SPST configurable) |
| Power Supply | 230 VAC ±10% / 115 VAC ±10%, 50–60 Hz |
| Enclosure Material | Stainless steel (IP65-rated housing) |
| Dimensions (H×W×D) | 125 × 185 × 125 mm (ISM-3i), 125 × 185 × 160 mm (ISM-3x w/ integrated display) |
| Weight | 3.7 kg (ISM-3i), 3.8 kg (ISM-3x) |
| Brand | Mocon |
|---|---|
| Model | Dansensor LeakMatic II |
| Origin | Denmark |
| Type | Online Non-Destructive CO₂-Based Leak Detection System for Modified Atmosphere Packaging (MAP) |
| Max. Test Speed | 4 cartons/min |
| Max. Package Dimensions (with fill) | 330 × 610 × 300 mm (L×W×H) |
| Sensor Type | Optical CO₂ Sensor |
| Test Pressure Range | Down to 300 mbar absolute |
| Warm-up Time | 1 min (cold start), 20 sec (from standby) |
| Number of Programmable Test Methods | 16 |
| Interface | Dual RS232 ports, Relay outputs (≤48 V/1 A) |
| Power Supply | 400 VAC |
| Weight | ~450 kg |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optech-O2 P |
| Power Supply | USB-powered (2.5 W) |
| Operating Temperature | 5–40 °C (Headspace Mode), 10–35 °C (Dissolved O₂ Mode) |
| Measurement Principle | Fluorescence-based Confocal Optical Sensing |
| Detection Range (Headspace) | 0.050%–25% O₂ (500 ppm–250,000 ppm) |
| Detection Range (ImPULSE™ Adhesive Sensor) | 0.001%–25% O₂ (10 ppm–250,000 ppm) |
| Repeatability (Needle Probe, 0–150 mmHg) | ±0.100% O₂ or ±5% of reading (whichever is greater) |
| Repeatability (Needle Probe, 150–1000 mmHg) | ±0.015% O₂ or ±2% of reading (whichever is greater) |
| Repeatability (ImPULSE™ Sensor) | ±0.015% O₂ or ±3% of reading (whichever is greater) |
| Probe Dimensions (w/ Needle) | 4.83 × 3.30 × 15.24 cm (H×W×D) |
| Probe Dimensions (w/o Needle) | 4.83 × 3.30 × 22.86 cm (H×W×D) |
| Preheat Time | 20 min |
| Compliance | CE, CSA, UL certified |
| Pressure Compensation | Integrated for needle-based measurements |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckPoint 4 |
| Origin | Denmark |
| Detection Gases | O₂ and CO₂ (selectable single or dual) |
| Measurement Principle | Electrochemical (O₂), Infrared (CO₂) |
| Portability | Handheld, battery-powered |
| Interface | Capacitive touchscreen with 10 language options |
| Compliance | Designed for ISO 22000, HACCP, and GMP-aligned quality control environments |
| Power | Rechargeable Li-ion battery with rugged charging port |
| Accessories | Standard low-cost hypodermic needle probe (22G), optional protective boot |
| Auto-shutdown | Yes, energy-saving mode |
| Gas flow alarm | Visual and audible alert |
| Certifications | CE, RoHS, FDA-compliant design (non-invasive testing per 21 CFR Part 11 data integrity guidelines) |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MultiCheck 2 |
| Price Range | USD 13,500 – 27,000 |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckMate 4 SV |
| Origin | Denmark |
| Gas Measurement | O₂ or O₂ + CO₂ |
| Principle | Zirconia (O₂), Electrochemical (O₂), Dual-Beam Infrared (CO₂), Optical Fluorescence (O₂) |
| Sampling Method | Non-invasive optical probe or minimally invasive needle-penetration |
| Minimum Sample Volume | None |
| Resolution | 0.001% |
| Accuracy | ±0.02% |
| Compliance | Designed for ISO 8573-1, ASTM F2714, USP <1207>, FDA 21 CFR Part 11–ready software architecture |
| User Interface | Multi-language capacitive touchscreen (10 languages) |
| Data Management | On-device storage with timestamped audit trail, optional PC-based Dansensor Insight™ software for multi-line monitoring and GLP/GMP-compliant reporting |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | Lippke 5000 |
| Test Pressure Range | 10–5000 mbar |
| Resolution | 0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar) |
| Accuracy | ±0.5 mbar or ±1% of reading (whichever is greater) |
| Test Volume Capacity | 0–90,000 mL |
| Test Duration | 1–500 s |
| Data Storage | >1,000,000 records |
| Interface | USB 2.0 (Host & Device), RJ-45 Ethernet |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MAP Mix Provectus |
| Price Range | USD 13,500 – 27,000 |
| Gas Types Supported | O₂, N₂, CO₂, Air, Ar (optional) |
| Mixing Configurations | 2-gas or 3-gas |
| Max Total Output Flow | 1500 L/min (3-gas mode) |
| Flow Accuracy | ±2% at ≥50 L/min |
| Input Pressure Range | 2–10 bar |
| Pressure Drop | ≤1 bar at 10 bar inlet |
| Flow Control Range per Gas | 6–500 L/min |
| Operating Temperature | 0–50 °C |
| Display | Touchscreen LCD |
| Connectivity | RS232 ×2, Ethernet (10/100 Mbit, Modbus TCP), USB, 24 VDC I/O |
| Power Supply | 103–132 / 207–264 VAC, 47–63 Hz or 24 VDC |
| Dimensions (H×W×D) | 192 × 230 × 375 mm |
| Weight | 12.0–14.0 kg |
| IP Rating (with optional kit) | IP45 (NEMA 3S) |
| Compliance | CE-marked |
| Predefined Programs | Up to 10 standard gas mixtures |
| Data Logging | Timestamped flow, pressure, mixture ratio, runtime, total consumption |
| Integration | Fully compatible with Dansensor MAP Check 3 gas analyzers |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Model | MAP Mix 9001 ME |
| Gas Channels | 2 or 3 |
| Flow Range | 20–400 L/min (40–850 SCFH) |
| Max Output Pressure | 6 bar |
| Input Pressure Range | 5.5–10 bar (varies by configuration) |
| Accuracy | ±2% (at 15–100% flow, 10–90% blend ratio) |
| Housing Material | Stainless Steel |
| Compliance | CE-marked |
| Dimensions (D×H×W) | 420 × 194 × 235 mm |
| Weight | 10–12 kg |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dansensor MAP Check 3 |
| Price Range | USD 6,800 – 13,600 |
| Oxygen Sensor Type | Electrochemical, Range: 0–100% O₂, Accuracy: ±0.01% abs (≤1% O₂), ±1% rel (>1% O₂) |
| CO₂ Sensor Type | Heated Dual-Beam NDIR, Range: 0–100% CO₂, Accuracy: ±0.5% abs, ±1.5% rel |
| Warm-up Time | 10 min (O₂), 8 min (CO₂) |
| Gas Flow Rate | 6–500 L/min |
| Inlet Pressure | 2–10 bar |
| Pressure Drop | 1 bar @ 10 bar inlet |
| Communication Interfaces | 2× RS232C, LAN 10/100 Mbit (Modbus TCP), USB, 4–20 mA / 0–10 V analog outputs, 24 VDC logic I/O |
| Power Supply | 103–132 / 207–264 VAC, auto-ranging, 47–63 Hz |
| Dimensions (H×W×D) | 192 × 230 × 375 mm |
| Weight | 8.5–11.5 kg |
| Enclosure Rating (optional) | IP45 (NEMA 3S) |
| Compliance | CE-marked, RoHS-compliant |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | LeakPointer 3 |
| Detection Limit | 50 µm |
| Test Cycle Time | 10 s per package |
| Max. Chamber Vacuum | –750 mbar |
| CO₂ Sensor Type | NDIR |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 100–260 VAC, 50/60 Hz |
| Dimensions (open lid) | 617 mm H × 543 mm W × 400 mm D |
| Weight | 20 kg |
| Data Storage Capacity | >1,000,000 test records |
| Compliance | CE-marked |
| Recommended CO₂ Ambient Level | <1500 ppm |
| Calibration Interval | Every 12 months |
| Brand | MOCON / Dansensor |
|---|---|
| Origin | Denmark |
| Model | CheckMate 4 |
| Measurement Gases | O₂ only or O₂ + CO₂ dual-sensor configuration |
| Detection Principle | Electrochemical (O₂) and Infrared (CO₂) |
| Sample Volume Required | < 2 mL |
| Data Storage Capacity | Up to 1,000,000 test records |
| User Profiles | Configurable individual logins with role-based access |
| Interface | 7-inch capacitive multi-touch LCD (English, Spanish, French, German, Chinese, Portuguese, Russian) |
| Connectivity | Ethernet (LAN), USB 2.0 (for barcode scanner, keyboard, printer, or data export via USB drive) |
| Sensor Module Design | Field-replaceable, pre-calibrated modular sensors |
| Compliance | Designed to support GLP/GMP environments |
| Calibration | Factory-calibrated |