Add to compare
BrandMocon
OriginDenmark
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDansensor ISM-3
Measurement Range1 ppm – 100 % O₂ (std. 0–20.9 %)
Accuracy±1% of reading
Sensor TypeCeramic Solid-State Electrochemical
Response Time<60 s (t₉₀)
Flow Rate125 mL/min
Warm-up Time10 min (operational), 20 min (full stabilization)
Calibration Interval12 months
Output Signal4–20 mA (standard), optional 0–10 V
Alarm Outputs2 programmable O₂ alarms + system fault alarm (max. 48 V, 1 A, SPST configurable)
Power Supply230 VAC ±10% / 115 VAC ±10%, 50–60 Hz
Enclosure MaterialStainless steel (IP65-rated housing)
Dimensions (H×W×D)125 × 185 × 125 mm (ISM-3i), 125 × 185 × 160 mm (ISM-3x w/ integrated display)
Weight3.7 kg (ISM-3i), 3.8 kg (ISM-3x)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMocon
ModelDansensor LeakMatic II
OriginDenmark
TypeOnline Non-Destructive CO₂-Based Leak Detection System for Modified Atmosphere Packaging (MAP)
Max. Test Speed4 cartons/min
Max. Package Dimensions (with fill)330 × 610 × 300 mm (L×W×H)
Sensor TypeOptical CO₂ Sensor
Test Pressure RangeDown to 300 mbar absolute
Warm-up Time1 min (cold start), 20 sec (from standby)
Number of Programmable Test Methods16
InterfaceDual RS232 ports, Relay outputs (≤48 V/1 A)
Power Supply400 VAC
Weight~450 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMocon
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelOptech-O2 P
Power SupplyUSB-powered (2.5 W)
Operating Temperature5–40 °C (Headspace Mode), 10–35 °C (Dissolved O₂ Mode)
Measurement PrincipleFluorescence-based Confocal Optical Sensing
Detection Range (Headspace)0.050%–25% O₂ (500 ppm–250,000 ppm)
Detection Range (ImPULSE™ Adhesive Sensor)0.001%–25% O₂ (10 ppm–250,000 ppm)
Repeatability (Needle Probe, 0–150 mmHg)±0.100% O₂ or ±5% of reading (whichever is greater)
Repeatability (Needle Probe, 150–1000 mmHg)±0.015% O₂ or ±2% of reading (whichever is greater)
Repeatability (ImPULSE™ Sensor)±0.015% O₂ or ±3% of reading (whichever is greater)
Probe Dimensions (w/ Needle)4.83 × 3.30 × 15.24 cm (H×W×D)
Probe Dimensions (w/o Needle)4.83 × 3.30 × 22.86 cm (H×W×D)
Preheat Time20 min
ComplianceCE, CSA, UL certified
Pressure CompensationIntegrated for needle-based measurements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON (Dansensor)
ModelCheckPoint 4
OriginDenmark
Detection GasesO₂ and CO₂ (selectable single or dual)
Measurement PrincipleElectrochemical (O₂), Infrared (CO₂)
PortabilityHandheld, battery-powered
InterfaceCapacitive touchscreen with 10 language options
ComplianceDesigned for ISO 22000, HACCP, and GMP-aligned quality control environments
PowerRechargeable Li-ion battery with rugged charging port
AccessoriesStandard low-cost hypodermic needle probe (22G), optional protective boot
Auto-shutdownYes, energy-saving mode
Gas flow alarmVisual and audible alert
CertificationsCE, RoHS, FDA-compliant design (non-invasive testing per 21 CFR Part 11 data integrity guidelines)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginDenmark
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMultiCheck 2
Price RangeUSD 13,500 – 27,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON (Dansensor)
ModelCheckMate 4 SV
OriginDenmark
Gas MeasurementO₂ or O₂ + CO₂
PrincipleZirconia (O₂), Electrochemical (O₂), Dual-Beam Infrared (CO₂), Optical Fluorescence (O₂)
Sampling MethodNon-invasive optical probe or minimally invasive needle-penetration
Minimum Sample VolumeNone
Resolution0.001%
Accuracy±0.02%
ComplianceDesigned for ISO 8573-1, ASTM F2714, USP <1207>, FDA 21 CFR Part 11–ready software architecture
User InterfaceMulti-language capacitive touchscreen (10 languages)
Data ManagementOn-device storage with timestamped audit trail, optional PC-based Dansensor Insight™ software for multi-line monitoring and GLP/GMP-compliant reporting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginDenmark
ModelLippke 5000
Test Pressure Range10–5000 mbar
Resolution0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar)
Accuracy±0.5 mbar or ±1% of reading (whichever is greater)
Test Volume Capacity0–90,000 mL
Test Duration1–500 s
Data Storage>1,000,000 records
InterfaceUSB 2.0 (Host & Device), RJ-45 Ethernet
ComplianceASTM F1140, F2054, F2095, F2096
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMocon
OriginDenmark
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMAP Mix Provectus
Price RangeUSD 13,500 – 27,000
Gas Types SupportedO₂, N₂, CO₂, Air, Ar (optional)
Mixing Configurations2-gas or 3-gas
Max Total Output Flow1500 L/min (3-gas mode)
Flow Accuracy±2% at ≥50 L/min
Input Pressure Range2–10 bar
Pressure Drop≤1 bar at 10 bar inlet
Flow Control Range per Gas6–500 L/min
Operating Temperature0–50 °C
DisplayTouchscreen LCD
ConnectivityRS232 ×2, Ethernet (10/100 Mbit, Modbus TCP), USB, 24 VDC I/O
Power Supply103–132 / 207–264 VAC, 47–63 Hz or 24 VDC
Dimensions (H×W×D)192 × 230 × 375 mm
Weight12.0–14.0 kg
IP Rating (with optional kit)IP45 (NEMA 3S)
ComplianceCE-marked
Predefined ProgramsUp to 10 standard gas mixtures
Data LoggingTimestamped flow, pressure, mixture ratio, runtime, total consumption
IntegrationFully compatible with Dansensor MAP Check 3 gas analyzers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMocon
OriginDenmark
ModelMAP Mix 9001 ME
Gas Channels2 or 3
Flow Range20–400 L/min (40–850 SCFH)
Max Output Pressure6 bar
Input Pressure Range5.5–10 bar (varies by configuration)
Accuracy±2% (at 15–100% flow, 10–90% blend ratio)
Housing MaterialStainless Steel
ComplianceCE-marked
Dimensions (D×H×W)420 × 194 × 235 mm
Weight10–12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMocon
OriginDenmark
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDansensor MAP Check 3
Price RangeUSD 6,800 – 13,600
Oxygen Sensor TypeElectrochemical, Range: 0–100% O₂, Accuracy: ±0.01% abs (≤1% O₂), ±1% rel (>1% O₂)
CO₂ Sensor TypeHeated Dual-Beam NDIR, Range: 0–100% CO₂, Accuracy: ±0.5% abs, ±1.5% rel
Warm-up Time10 min (O₂), 8 min (CO₂)
Gas Flow Rate6–500 L/min
Inlet Pressure2–10 bar
Pressure Drop1 bar @ 10 bar inlet
Communication Interfaces2× RS232C, LAN 10/100 Mbit (Modbus TCP), USB, 4–20 mA / 0–10 V analog outputs, 24 VDC logic I/O
Power Supply103–132 / 207–264 VAC, auto-ranging, 47–63 Hz
Dimensions (H×W×D)192 × 230 × 375 mm
Weight8.5–11.5 kg
Enclosure Rating (optional)IP45 (NEMA 3S)
ComplianceCE-marked, RoHS-compliant
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON
OriginDenmark
ModelLeakPointer 3
Detection Limit50 µm
Test Cycle Time10 s per package
Max. Chamber Vacuum–750 mbar
CO₂ Sensor TypeNDIR
Operating Temperature+5 °C to +35 °C
Power Supply100–260 VAC, 50/60 Hz
Dimensions (open lid)617 mm H × 543 mm W × 400 mm D
Weight20 kg
Data Storage Capacity>1,000,000 test records
ComplianceCE-marked
Recommended CO₂ Ambient Level<1500 ppm
Calibration IntervalEvery 12 months
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMOCON / Dansensor
OriginDenmark
ModelCheckMate 4
Measurement GasesO₂ only or O₂ + CO₂ dual-sensor configuration
Detection PrincipleElectrochemical (O₂) and Infrared (CO₂)
Sample Volume Required< 2 mL
Data Storage CapacityUp to 1,000,000 test records
User ProfilesConfigurable individual logins with role-based access
Interface7-inch capacitive multi-touch LCD (English, Spanish, French, German, Chinese, Portuguese, Russian)
ConnectivityEthernet (LAN), USB 2.0 (for barcode scanner, keyboard, printer, or data export via USB drive)
Sensor Module DesignField-replaceable, pre-calibrated modular sensors
ComplianceDesigned to support GLP/GMP environments
CalibrationFactory-calibrated