| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 Series |
| Instrument Type | Portable |
| Measurement Principle | Infrared Absorption (Transmittance/Reflectance) |
| Compliance | ASTM D7066 (Transmittance Method), EPA Method 1664 (Reflectance Method) |
| Power Source | Rechargeable Lithium Battery |
| Calibration | Multi-curve Internal Calibration |
| Data Handling | Onboard Storage & USB/Bluetooth Export |
| Security | Password-Protected User Settings & Calibration Curves |
| Alarm | Configurable Threshold Alerts |
| Environmental Rating | Ruggedized for Field Use |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 TOG/TPH |
| Instrument Type | Portable |
| Compliance | ASTM D7066, EPA Method 413.2 & 418.1, Equivalent to EPA 1664 & ISO 9377-2 |
| Measurement Principle | Fixed-Filter Infrared Absorption at 3.4 µm C–H Stretch Band |
| Detection Range | Sub-ppm to % w/w (oil-in-water, TPH in soil, FOG in wastewater) |
| Data Storage | Internal memory for ≥1,000 test records |
| Interface | USB 2.0 for data export |
| Calibration | Multi-point calibration curves with user-defined curve management |
| Security | Password-protected settings and calibration access |
| Environmental Rating | IP65-rated enclosure |
| Brand | Wilks |
|---|---|
| Origin | USA |
| Model | InfraCal2 |
| Instrument Type | Portable |
| Principle | Infrared Spectrophotometry (C–H Stretch Absorption at ~2960 cm⁻¹) |
| Measurement Range | 0.3–1000 ppm (as oil) |
| Detection Limit | 0.3 ppm |
| Accuracy | ±0.3 ppm (at low end, per ASTM D7066) |
| Resolution | 2 ppm |
| Data Storage | Internal memory for ≥500 results |
| Power | Rechargeable Li-ion battery |
| Interface | USB 2.0 for data export |
| Solvent Consumption per Test | 0.2 mL |
| Calibration | Multi-point, user-definable curves for TOG, FOG, TPH |
| Brand | Wilks Instrument |
|---|---|
| Origin | USA |
| Model | TRANS-SP |
| Detection Principle | Infrared Absorption at 2930 cm⁻¹ (3.4 µm) |
| Detection Limits | 0.1 ppm (water), 1 ppm (soil) |
| Extractants | Perchloroethylene, S-316, Freon-113, or other IR-transparent solvents |
| Compliance | EPA Method 1664, EPA Methods 413.2 & 418.1, ASTM D7066-04, ISO 9377-2 |
| Sample Cell | 10-mm pathlength fused quartz cuvette with PTFE-sealed cap |
| Power | 18 V DC, 3.3 A (internal Li-ion battery + universal AC/DC adapter) |
| Dimensions | 17 cm × 19.8 cm × 13.2 cm |
| Weight | 2.6 kg (net), 3.2 kg (with battery) |
| Operating Temperature | 5–40 °C |
| Analysis Time | 10–15 min (including extraction) |
| Repeatability | ±0.1 ppm |
| Data Interface | USB, RS-232 |
| Calibration Options | Multi-curve support (low/high concentration, S-316 or PCE-based), password-protected configuration |