BrandSpectro Scientific
OriginUSA
ModelInfraCal 2 Series
Instrument TypePortable
Measurement PrincipleInfrared Absorption (Transmittance/Reflectance)
ComplianceASTM D7066 (Transmittance Method), EPA Method 1664 (Reflectance Method)
Power SourceRechargeable Lithium Battery
CalibrationMulti-curve Internal Calibration
Data HandlingOnboard Storage & USB/Bluetooth Export
SecurityPassword-Protected User Settings & Calibration Curves
AlarmConfigurable Threshold Alerts
Environmental RatingRuggedized for Field Use
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelInfraCal 2 TOG/TPH
Instrument TypePortable
ComplianceASTM D7066, EPA Method 413.2 & 418.1, Equivalent to EPA 1664 & ISO 9377-2
Measurement PrincipleFixed-Filter Infrared Absorption at 3.4 µm C–H Stretch Band
Detection RangeSub-ppm to % w/w (oil-in-water, TPH in soil, FOG in wastewater)
Data StorageInternal memory for ≥1,000 test records
InterfaceUSB 2.0 for data export
CalibrationMulti-point calibration curves with user-defined curve management
SecurityPassword-protected settings and calibration access
Environmental RatingIP65-rated enclosure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWilks
OriginUSA
ModelInfraCal2
Instrument TypePortable
PrincipleInfrared Spectrophotometry (C–H Stretch Absorption at ~2960 cm⁻¹)
Measurement Range0.3–1000 ppm (as oil)
Detection Limit0.3 ppm
Accuracy±0.3 ppm (at low end, per ASTM D7066)
Resolution2 ppm
Data StorageInternal memory for ≥500 results
PowerRechargeable Li-ion battery
InterfaceUSB 2.0 for data export
Solvent Consumption per Test0.2 mL
CalibrationMulti-point, user-definable curves for TOG, FOG, TPH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWilks Instrument
OriginUSA
ModelTRANS-SP
Detection PrincipleInfrared Absorption at 2930 cm⁻¹ (3.4 µm)
Detection Limits0.1 ppm (water), 1 ppm (soil)
ExtractantsPerchloroethylene, S-316, Freon-113, or other IR-transparent solvents
ComplianceEPA Method 1664, EPA Methods 413.2 & 418.1, ASTM D7066-04, ISO 9377-2
Sample Cell10-mm pathlength fused quartz cuvette with PTFE-sealed cap
Power18 V DC, 3.3 A (internal Li-ion battery + universal AC/DC adapter)
Dimensions17 cm × 19.8 cm × 13.2 cm
Weight2.6 kg (net), 3.2 kg (with battery)
Operating Temperature5–40 °C
Analysis Time10–15 min (including extraction)
Repeatability±0.1 ppm
Data InterfaceUSB, RS-232
Calibration OptionsMulti-curve support (low/high concentration, S-316 or PCE-based), password-protected configuration