Empowering Scientific Discovery

Amtech Spire Technologies Inc.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelSpectrOil M
Detection MethodRotating Disc Electrode Atomic Emission Spectroscopy (RDE-OES)
ComplianceASTM D6595, ASTM D6728
Max Elements Detected31
Analysis Time≤30 s per sample
Power RequirementStandard AC mains
Sample PrepNone required
Operating EnvironmentMIL-STD-810G compliant (shock/vibration per JOAP CID-0191)
Integrated ComputingIndustrial-grade touchscreen PC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelLaserNet 200
Product TypeLaboratory Instrument
Particle Sizing Range4–100 µm
Max. Particle Concentration5,000,000 particles/mL
Viscosity Range (undiluted)15–320 cSt
Detection of Water Droplets & Air BubblesYes
Compliance StandardsISO 4406, NAS 1638, SAE AS4059, ASTM D6786, NAVAIR 01-1A-17, GOST, HAL
Optional ModulesFerrous Particle Monitoring (ppm + size distribution ≥25 µm), Morphological Imaging & Neural Network-Based Classification (≥20 µm), Kinematic & Dynamic Viscosity Measurement at 40 °C, Automated Sample Processor (ASP) for 24 samples
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelFDM Vial Kit (Qty 50)
Package50 vials per kit
Part Number346162035
ApplicationFuel dilution analysis in lubricating oil samples
ComplianceDesigned for use with ASTM D3524, D7897, and ISO 3104-compliant instrumentation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelT2FM500
ApplicationAnalytical Ferrography for Wear Particle Analysis in Lubricants, Hydraulic Fluids, Coolants, and Fuels
ComplianceASTM D7684, ASTM D7690
Particle Size Range0–800 µm
Operating PrincipleGravity-fed, Magnetic Deposition Ferrography
Sample Preparation MethodSolvent-assisted rinsing and air-drying of ferrogram slides
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMiniVisc 3000 Series
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelMiniLab EL
ApplicationElemental Analysis of Lubricating Oils
Instrument TypeBenchtop/Field-Deployable Laboratory Analyzer
ComplianceDesigned for ASTM D6595, ASTM D5185, ISO 8217, SAE J183, MIL-STD-3007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelLaserNet 230
Detection CapabilitiesSimultaneous particle counting, ferrous particle quantification (ppm & size distribution), and morphology-based wear debris classification
Particle Size Range (counting)4–100 µm
Max. Particle Concentration5,000,000 particles/mL
Viscosity Range15–320 cSt (no dilution required)
Soot Toleranceup to 2% (w/w)
Counting Uncertainty<2% (statistical repeatability)
Standards ComplianceISO 4406, NAS 1638, SAE AS4059, ASTM D6786, NAVAIR 01-1A-17, GOST, HAL
Imaging Resolution≥20 µm for automated morphology classification
Ferrous Sensor SensitivitySub-ppm detection limit for ferrous concentration
Analysis Time per Sample~4 minutes
Data IntegrationNative export to SpectroTrack LIMS and AMS Asset Management System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRABNER
OriginAustria
ModelMINIVAP VP Vision
Analysis MethodTriple Expansion Method
Pressure Range0–2000 kPa
Temperature Range0–120 °C
Repeatability≤ 0.2 kPa (pure substance @ 37.8 °C)
Reproducibility≤ 0.5 kPa (pure substance @ 37.8 °C)
Sample Volume1 mL
Test Time~5 min (method-dependent)
Display10-inch industrial-grade touchscreen
ComplianceASTM D5191, D6377, D6378, D6897, D5188, EN 13016-1+2, IP 394/409/481, JIS K2258-2, GOST 52340, SH/T 0769, SH/T 0794, GB/T 11509, GB/T 8017-2012
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelLaserNet 200 Series
Particle Sizing Range4–100 µm
Max. Particle Concentration10,000,000 particles/mL (<2% error)
Viscosity CompatibilityISO VG 15–320 (no dilution required)
Ferrous Particle Detection Time20 s
Standards ComplianceASTM D7596, ASTM D6786, ASTM D8120, ISO 4406, NAS 1638, SAE AS4059, NAVAIR 01-1A-17, GOST, HAL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelMiniVisc 3000
Kinematic Viscosity Range10–350 cSt @ 40 °C
Sample Volume60 µL
Temperature Control40 °C ± 0.1 °C
PowerRechargeable Li-ion battery (≥6 h operation)
Weight1.8 kg
Measurement PrincipleHele-Shaw flow in split-cell microchannel
ComplianceASTM D445, ISO 3104, IP 71 (indirectly supported via methodology and calibration traceability)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelMicroLab 30
Detection CapabilitiesElemental Analysis (via Rotating Disc Electrode Atomic Emission Spectrometry), Infrared Spectroscopy, Kinematic Viscosity (at 40 °C and 100 °C), Acid Number, Oxidation, Nitration, Soot, Glycol, Water, Particle Count (optional module), Additive & Contaminant Elemental Profiling
ComplianceASTM D7417 (Standard Test Method for Determination of Oxidation, Nitration, Soot, Glycol, Water, and Elemental Composition in Used Lubricating Oils Using Fourier Transform Infrared (FTIR) Spectroscopy, Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES), and Kinematic Viscosity)
SoftwareEmbedded Expert System with >10,000 rule-based diagnostic scripts
Sample Throughput~15 minutes per sample (full suite of ASTM D7417–compliant tests)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelInfraCal 2 ATR-B
Measurement PrincipleAttenuated Total Reflectance (ATR) Mid-Infrared Spectroscopy
Compliant StandardsASTM D7371, EN 14078
Detection Range0–100% biodiesel in diesel
Repeatability±0.2% (0–30%), ±1.0% (30–100%)
Analysis Time<30 seconds
Power SupplyRechargeable Li-ion battery (18 V DC, 3.3 A), >6 h operation
Weight2.6 kg (net), 3.2 kg (with battery)
Dimensions17 × 19.8 × 13.2 cm
Operating Temperature5–40 °C
InterfaceTouchscreen display, USB, RS-232
Data StorageInternal memory with user, location, date/time stamping
Language SupportEnglish, Spanish, French, Arabic
Calibration OptionsPre-loaded ATR-B curve (405-2041-24), optional multi-point calibration kits (e.g., 403-1024)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelMinilab 153
Detection CapabilitiesElemental Analysis (24 elements standard, up to 31), Particle Counting, Ferrous Particle Quantification (ppm) & Size Distribution, Kinematic Viscosity at 40 °C, TAN/TBN, Oxidation/Sulfation/Nitration, Water Content, Glycol, Soot
Software PlatformTruVu 360 Oil Intelligence Platform
ComplianceDesigned for ASTM D6595 (rotary disc electrode emission spectroscopy), ISO 4406 (particle contamination), ASTM D2440 (TAN), ASTM D974 (TBN), ASTM D2896 (TBN), ASTM D7945 (viscosity), and supports GLP/GMP audit trails per FDA 21 CFR Part 11 requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelSpectroTrack
ArchitectureBrowser-based (B/S)
ComplianceDesigned for ISO/IEC 17025, ASTM D6595, D7684, D7690, and FDA 21 CFR Part 11-ready workflows
IntegrationNative support for Spectro Scientific analyzers including Spectroil Q100, LNF-Q200, SpectroVISC, and FluidScan platforms
DeploymentOn-premise or secure cloud-hosted
User AccessRole-based authentication with audit trail logging
Data HandlingStructured metadata capture for samples, assets, instruments, clients, and test methods
ReportingAutomated PDF/Excel report generation with customizable templates
TrendingTime-series analysis of elemental concentrations, viscosity, oxidation, nitration, soot, water, and particle counts
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelFieldLab 58C
Product TypePortable Instrument
Detection ModulesXRF Elemental Analysis
Test Time per Sample<10 minutes
Sample Volume Required12 mL
ComplianceASTM D6595, D7690, D7883, D445
InterfaceTouchscreen with Embedded Diagnostic Software
PowerRechargeable Battery
EnclosureRuggedized Transport Case Integrating All Four Modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelLNF220
TypeLaser-based Direct Imaging Ferrography System
Detection PrinciplePulsed Laser Illumination + High-Speed CCD Imaging + AI-Powered Particle Classification
OutputParticle Count, Morphology Classification (Cutting, Sliding, Fatigue, Non-Metallic, Fiber, Bubble, Water)
ComplianceDesigned for ASTM D7690 (Standard Practice for Analysis of Wear Debris Using Direct-Imaging Ferrography)
SoftwareEmbedded Neural Network Algorithm Suite
ConnectivityEthernet, USB 3.0
Sample ThroughputUp to 12 samples/hour (automated mode)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelSpectrOil 120C
Detection PrincipleRotating Disc Electrode (RDE) Atomic Emission Spectrometry
Compliant StandardsASTM D6595 (Used Lubricants), ASTM D6728 (Fuel Oils)
Sample Volume2 mL
Analysis Time≤30 seconds per sample
Elements QuantifiedUp to 31 elements (24 standard + 7 optional)
Detection LimitsSub-ppm for most metallic elements
Sample PreparationNone — direct oil injection
Gas RequirementNone
Application ScopeIn-service lubricant wear debris, contaminant, and additive analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFluidScan
Product TypePortable Instrument
Detection ParametersContaminants, Oxidation, Acid Number (AN), Base Number (BN), Water Content (Free & Dissolved), Fluid Identity
ComplianceASTM D7889, JOAP Standards
Measurement PrincipleMid-Infrared (MIR) Absorption Spectroscopy
Sample Volume1 Drop (~50 µL)
Analysis Time≤ 60 Seconds
Onboard Database> 800 Lubricant & Grease Reference Spectra
CalibrationFactory-Calibrated with Industry-Validated Algorithms
ReportingAutomated PDF Report Generation
Software IntegrationFluidScan Manager (Windows-based Database & Trending Software)
Regulatory SupportAudit Trail, User Access Control, Data Export for GLP/GMP Environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
ModelMobileLab
Power SupplyDual 12 V DC (rechargeable battery) & 230 V AC input
Environmental ControlIndependent HVAC panel with 20 air changes/hour
MountingSeismically damped instrument racks
Water SystemIntegrated sink with fresh/distilled water supply and dedicated waste container
Data IntegrationCentralized software via RS-232/USB serial interface
Compliance SupportDesigned for ASTM D93, D130, D2887, D445, ISO 3104, ISO 2719, EN 13016, GOST R 51105, and related fuel testing standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelMicrolab 40
ApplicationElemental Analysis, Particle Counting, Viscosity, Oxidation/Nitration/Total Base Number (TBN), Coolant & Water Contamination, Soot Measurement
ComplianceASTM D6595 (Rotary Disc Electrode Emission Spectrometry), ASTM D7690 (Automatic Particle Counting), ASTM D445 (Kinematic Viscosity), ASTM D2896/D4739 (TBN), ISO 4406:2017 (Particle Contamination Code)
ConfigurationBenchtop, Integrated Lab-Scale Analyzer for On-Site or Centralized Lubricant Diagnostics
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelFerroCheck 2000
TypePortable Instrument
ComplianceASTM D8120
Detection PrincipleMagnetic Susceptibility-Based Impedance Measurement
Sample Volume1.5 mL (oil), 0.75 mL (grease)
Analysis Time≤30 s
Detection Limit<3 ppm Fe
Repeatability±2% RSD
PowerRechargeable Li-ion battery (4 h runtime)
Data OutputCSV, AMS OilView-compatible
CalibrationPre-loaded with certified calibration standards
Temperature CompensationAutomatic real-time coil current balancing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMiniVisc 3050
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
Model120C
ApplicationElemental Analysis of Lubricating Oils, Fuels, Coolants, and Industrial Fluids
ComplianceASTM D6595, ASTM D6728
Sample Volume2 mL
Analysis Time≤30 s per sample
Elements QuantifiedUp to 31 metals
Detection LimitsSub-ppm for most elements
Sample PreparationSolvent-free, no dilution required
ConfigurationBenchtop laboratory spectrometer
Intended UseWear debris monitoring, additive package verification, contamination screening
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelFluidScan 1000 Series
Instrument TypePortable Analyzer
Measurement ParametersWater Content, TAN (Total Acid Number), TBN (Total Base Number), Oxidation, Nitration, Sulfation, Glycol, Soot, Additive Depletion, Overall Oil Health Index
ComplianceASTM D7889, ASTM E2412, ASTM E1655
Sample Volume1 drop (~50 µL)
Analysis Time< 60 seconds per sample
Calibration Database> 850 reference spectra (mineral & synthetic oils, greases, biodiesel, fuels)
Cleaning MethodSolvent-free
Detection PrincipleFourier Transform Infrared (FTIR) Spectroscopy
PortabilityHandheld, battery-operated, field-deployable