- All
- Favorite
- Popular
- Most rated
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | SpectrOil M |
| Detection Method | Rotating Disc Electrode Atomic Emission Spectroscopy (RDE-OES) |
| Compliance | ASTM D6595, ASTM D6728 |
| Max Elements Detected | 31 |
| Analysis Time | ≤30 s per sample |
| Power Requirement | Standard AC mains |
| Sample Prep | None required |
| Operating Environment | MIL-STD-810G compliant (shock/vibration per JOAP CID-0191) |
| Integrated Computing | Industrial-grade touchscreen PC |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 |
| Product Type | Laboratory Instrument |
| Particle Sizing Range | 4–100 µm |
| Max. Particle Concentration | 5,000,000 particles/mL |
| Viscosity Range (undiluted) | 15–320 cSt |
| Detection of Water Droplets & Air Bubbles | Yes |
| Compliance Standards | ISO 4406, NAS 1638, SAE AS4059, ASTM D6786, NAVAIR 01-1A-17, GOST, HAL |
| Optional Modules | Ferrous Particle Monitoring (ppm + size distribution ≥25 µm), Morphological Imaging & Neural Network-Based Classification (≥20 µm), Kinematic & Dynamic Viscosity Measurement at 40 °C, Automated Sample Processor (ASP) for 24 samples |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FDM Vial Kit (Qty 50) |
| Package | 50 vials per kit |
| Part Number | 346162035 |
| Application | Fuel dilution analysis in lubricating oil samples |
| Compliance | Designed for use with ASTM D3524, D7897, and ISO 3104-compliant instrumentation |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | T2FM500 |
| Application | Analytical Ferrography for Wear Particle Analysis in Lubricants, Hydraulic Fluids, Coolants, and Fuels |
| Compliance | ASTM D7684, ASTM D7690 |
| Particle Size Range | 0–800 µm |
| Operating Principle | Gravity-fed, Magnetic Deposition Ferrography |
| Sample Preparation Method | Solvent-assisted rinsing and air-drying of ferrogram slides |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MiniVisc 3000 Series |
| Pricing | Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | MiniLab EL |
| Application | Elemental Analysis of Lubricating Oils |
| Instrument Type | Benchtop/Field-Deployable Laboratory Analyzer |
| Compliance | Designed for ASTM D6595, ASTM D5185, ISO 8217, SAE J183, MIL-STD-3007 |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 230 |
| Detection Capabilities | Simultaneous particle counting, ferrous particle quantification (ppm & size distribution), and morphology-based wear debris classification |
| Particle Size Range (counting) | 4–100 µm |
| Max. Particle Concentration | 5,000,000 particles/mL |
| Viscosity Range | 15–320 cSt (no dilution required) |
| Soot Tolerance | up to 2% (w/w) |
| Counting Uncertainty | <2% (statistical repeatability) |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ASTM D6786, NAVAIR 01-1A-17, GOST, HAL |
| Imaging Resolution | ≥20 µm for automated morphology classification |
| Ferrous Sensor Sensitivity | Sub-ppm detection limit for ferrous concentration |
| Analysis Time per Sample | ~4 minutes |
| Data Integration | Native export to SpectroTrack LIMS and AMS Asset Management System |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIVAP VP Vision |
| Analysis Method | Triple Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | 0–120 °C |
| Repeatability | ≤ 0.2 kPa (pure substance @ 37.8 °C) |
| Reproducibility | ≤ 0.5 kPa (pure substance @ 37.8 °C) |
| Sample Volume | 1 mL |
| Test Time | ~5 min (method-dependent) |
| Display | 10-inch industrial-grade touchscreen |
| Compliance | ASTM D5191, D6377, D6378, D6897, D5188, EN 13016-1+2, IP 394/409/481, JIS K2258-2, GOST 52340, SH/T 0769, SH/T 0794, GB/T 11509, GB/T 8017-2012 |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 Series |
| Particle Sizing Range | 4–100 µm |
| Max. Particle Concentration | 10,000,000 particles/mL (<2% error) |
| Viscosity Compatibility | ISO VG 15–320 (no dilution required) |
| Ferrous Particle Detection Time | 20 s |
| Standards Compliance | ASTM D7596, ASTM D6786, ASTM D8120, ISO 4406, NAS 1638, SAE AS4059, NAVAIR 01-1A-17, GOST, HAL |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | MiniVisc 3000 |
| Kinematic Viscosity Range | 10–350 cSt @ 40 °C |
| Sample Volume | 60 µL |
| Temperature Control | 40 °C ± 0.1 °C |
| Power | Rechargeable Li-ion battery (≥6 h operation) |
| Weight | 1.8 kg |
| Measurement Principle | Hele-Shaw flow in split-cell microchannel |
| Compliance | ASTM D445, ISO 3104, IP 71 (indirectly supported via methodology and calibration traceability) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | MicroLab 30 |
| Detection Capabilities | Elemental Analysis (via Rotating Disc Electrode Atomic Emission Spectrometry), Infrared Spectroscopy, Kinematic Viscosity (at 40 °C and 100 °C), Acid Number, Oxidation, Nitration, Soot, Glycol, Water, Particle Count (optional module), Additive & Contaminant Elemental Profiling |
| Compliance | ASTM D7417 (Standard Test Method for Determination of Oxidation, Nitration, Soot, Glycol, Water, and Elemental Composition in Used Lubricating Oils Using Fourier Transform Infrared (FTIR) Spectroscopy, Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES), and Kinematic Viscosity) |
| Software | Embedded Expert System with >10,000 rule-based diagnostic scripts |
| Sample Throughput | ~15 minutes per sample (full suite of ASTM D7417–compliant tests) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 ATR-B |
| Measurement Principle | Attenuated Total Reflectance (ATR) Mid-Infrared Spectroscopy |
| Compliant Standards | ASTM D7371, EN 14078 |
| Detection Range | 0–100% biodiesel in diesel |
| Repeatability | ±0.2% (0–30%), ±1.0% (30–100%) |
| Analysis Time | <30 seconds |
| Power Supply | Rechargeable Li-ion battery (18 V DC, 3.3 A), >6 h operation |
| Weight | 2.6 kg (net), 3.2 kg (with battery) |
| Dimensions | 17 × 19.8 × 13.2 cm |
| Operating Temperature | 5–40 °C |
| Interface | Touchscreen display, USB, RS-232 |
| Data Storage | Internal memory with user, location, date/time stamping |
| Language Support | English, Spanish, French, Arabic |
| Calibration Options | Pre-loaded ATR-B curve (405-2041-24), optional multi-point calibration kits (e.g., 403-1024) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | Minilab 153 |
| Detection Capabilities | Elemental Analysis (24 elements standard, up to 31), Particle Counting, Ferrous Particle Quantification (ppm) & Size Distribution, Kinematic Viscosity at 40 °C, TAN/TBN, Oxidation/Sulfation/Nitration, Water Content, Glycol, Soot |
| Software Platform | TruVu 360 Oil Intelligence Platform |
| Compliance | Designed for ASTM D6595 (rotary disc electrode emission spectroscopy), ISO 4406 (particle contamination), ASTM D2440 (TAN), ASTM D974 (TBN), ASTM D2896 (TBN), ASTM D7945 (viscosity), and supports GLP/GMP audit trails per FDA 21 CFR Part 11 requirements |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | SpectroTrack |
| Architecture | Browser-based (B/S) |
| Compliance | Designed for ISO/IEC 17025, ASTM D6595, D7684, D7690, and FDA 21 CFR Part 11-ready workflows |
| Integration | Native support for Spectro Scientific analyzers including Spectroil Q100, LNF-Q200, SpectroVISC, and FluidScan platforms |
| Deployment | On-premise or secure cloud-hosted |
| User Access | Role-based authentication with audit trail logging |
| Data Handling | Structured metadata capture for samples, assets, instruments, clients, and test methods |
| Reporting | Automated PDF/Excel report generation with customizable templates |
| Trending | Time-series analysis of elemental concentrations, viscosity, oxidation, nitration, soot, water, and particle counts |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58C |
| Product Type | Portable Instrument |
| Detection Modules | XRF Elemental Analysis |
| Test Time per Sample | <10 minutes |
| Sample Volume Required | 12 mL |
| Compliance | ASTM D6595, D7690, D7883, D445 |
| Interface | Touchscreen with Embedded Diagnostic Software |
| Power | Rechargeable Battery |
| Enclosure | Ruggedized Transport Case Integrating All Four Modules |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LNF220 |
| Type | Laser-based Direct Imaging Ferrography System |
| Detection Principle | Pulsed Laser Illumination + High-Speed CCD Imaging + AI-Powered Particle Classification |
| Output | Particle Count, Morphology Classification (Cutting, Sliding, Fatigue, Non-Metallic, Fiber, Bubble, Water) |
| Compliance | Designed for ASTM D7690 (Standard Practice for Analysis of Wear Debris Using Direct-Imaging Ferrography) |
| Software | Embedded Neural Network Algorithm Suite |
| Connectivity | Ethernet, USB 3.0 |
| Sample Throughput | Up to 12 samples/hour (automated mode) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | SpectrOil 120C |
| Detection Principle | Rotating Disc Electrode (RDE) Atomic Emission Spectrometry |
| Compliant Standards | ASTM D6595 (Used Lubricants), ASTM D6728 (Fuel Oils) |
| Sample Volume | 2 mL |
| Analysis Time | ≤30 seconds per sample |
| Elements Quantified | Up to 31 elements (24 standard + 7 optional) |
| Detection Limits | Sub-ppm for most metallic elements |
| Sample Preparation | None — direct oil injection |
| Gas Requirement | None |
| Application Scope | In-service lubricant wear debris, contaminant, and additive analysis |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FluidScan |
| Product Type | Portable Instrument |
| Detection Parameters | Contaminants, Oxidation, Acid Number (AN), Base Number (BN), Water Content (Free & Dissolved), Fluid Identity |
| Compliance | ASTM D7889, JOAP Standards |
| Measurement Principle | Mid-Infrared (MIR) Absorption Spectroscopy |
| Sample Volume | 1 Drop (~50 µL) |
| Analysis Time | ≤ 60 Seconds |
| Onboard Database | > 800 Lubricant & Grease Reference Spectra |
| Calibration | Factory-Calibrated with Industry-Validated Algorithms |
| Reporting | Automated PDF Report Generation |
| Software Integration | FluidScan Manager (Windows-based Database & Trending Software) |
| Regulatory Support | Audit Trail, User Access Control, Data Export for GLP/GMP Environments |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MobileLab |
| Power Supply | Dual 12 V DC (rechargeable battery) & 230 V AC input |
| Environmental Control | Independent HVAC panel with 20 air changes/hour |
| Mounting | Seismically damped instrument racks |
| Water System | Integrated sink with fresh/distilled water supply and dedicated waste container |
| Data Integration | Centralized software via RS-232/USB serial interface |
| Compliance Support | Designed for ASTM D93, D130, D2887, D445, ISO 3104, ISO 2719, EN 13016, GOST R 51105, and related fuel testing standards |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | Microlab 40 |
| Application | Elemental Analysis, Particle Counting, Viscosity, Oxidation/Nitration/Total Base Number (TBN), Coolant & Water Contamination, Soot Measurement |
| Compliance | ASTM D6595 (Rotary Disc Electrode Emission Spectrometry), ASTM D7690 (Automatic Particle Counting), ASTM D445 (Kinematic Viscosity), ASTM D2896/D4739 (TBN), ISO 4406:2017 (Particle Contamination Code) |
| Configuration | Benchtop, Integrated Lab-Scale Analyzer for On-Site or Centralized Lubricant Diagnostics |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FerroCheck 2000 |
| Type | Portable Instrument |
| Compliance | ASTM D8120 |
| Detection Principle | Magnetic Susceptibility-Based Impedance Measurement |
| Sample Volume | 1.5 mL (oil), 0.75 mL (grease) |
| Analysis Time | ≤30 s |
| Detection Limit | <3 ppm Fe |
| Repeatability | ±2% RSD |
| Power | Rechargeable Li-ion battery (4 h runtime) |
| Data Output | CSV, AMS OilView-compatible |
| Calibration | Pre-loaded with certified calibration standards |
| Temperature Compensation | Automatic real-time coil current balancing |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MiniVisc 3050 |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | 120C |
| Application | Elemental Analysis of Lubricating Oils, Fuels, Coolants, and Industrial Fluids |
| Compliance | ASTM D6595, ASTM D6728 |
| Sample Volume | 2 mL |
| Analysis Time | ≤30 s per sample |
| Elements Quantified | Up to 31 metals |
| Detection Limits | Sub-ppm for most elements |
| Sample Preparation | Solvent-free, no dilution required |
| Configuration | Benchtop laboratory spectrometer |
| Intended Use | Wear debris monitoring, additive package verification, contamination screening |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FluidScan 1000 Series |
| Instrument Type | Portable Analyzer |
| Measurement Parameters | Water Content, TAN (Total Acid Number), TBN (Total Base Number), Oxidation, Nitration, Sulfation, Glycol, Soot, Additive Depletion, Overall Oil Health Index |
| Compliance | ASTM D7889, ASTM E2412, ASTM E1655 |
| Sample Volume | 1 drop (~50 µL) |
| Analysis Time | < 60 seconds per sample |
| Calibration Database | > 850 reference spectra (mineral & synthetic oils, greases, biodiesel, fuels) |
| Cleaning Method | Solvent-free |
| Detection Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Portability | Handheld, battery-operated, field-deployable |
Show next