| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | SpectrOil M |
| Detection Method | Rotating Disc Electrode Atomic Emission Spectroscopy (RDE-OES) |
| Compliance | ASTM D6595, ASTM D6728 |
| Max Elements Detected | 31 |
| Analysis Time | ≤30 s per sample |
| Power Requirement | Standard AC mains |
| Sample Prep | None required |
| Operating Environment | MIL-STD-810G compliant (shock/vibration per JOAP CID-0191) |
| Integrated Computing | Industrial-grade touchscreen PC |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 |
| Product Type | Laboratory Instrument |
| Particle Sizing Range | 4–100 µm |
| Max. Particle Concentration | 5,000,000 particles/mL |
| Viscosity Range (undiluted) | 15–320 cSt |
| Detection of Water Droplets & Air Bubbles | Yes |
| Compliance Standards | ISO 4406, NAS 1638, SAE AS4059, ASTM D6786, NAVAIR 01-1A-17, GOST, HAL |
| Optional Modules | Ferrous Particle Monitoring (ppm + size distribution ≥25 µm), Morphological Imaging & Neural Network-Based Classification (≥20 µm), Kinematic & Dynamic Viscosity Measurement at 40 °C, Automated Sample Processor (ASP) for 24 samples |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FDM Vial Kit (Qty 50) |
| Package | 50 vials per kit |
| Part Number | 346162035 |
| Application | Fuel dilution analysis in lubricating oil samples |
| Compliance | Designed for use with ASTM D3524, D7897, and ISO 3104-compliant instrumentation |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | MiniLab EL |
| Application | Elemental Analysis of Lubricating Oils |
| Instrument Type | Benchtop/Field-Deployable Laboratory Analyzer |
| Compliance | Designed for ASTM D6595, ASTM D5185, ISO 8217, SAE J183, MIL-STD-3007 |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 230 |
| Detection Capabilities | Simultaneous particle counting, ferrous particle quantification (ppm & size distribution), and morphology-based wear debris classification |
| Particle Size Range (counting) | 4–100 µm |
| Max. Particle Concentration | 5,000,000 particles/mL |
| Viscosity Range | 15–320 cSt (no dilution required) |
| Soot Tolerance | up to 2% (w/w) |
| Counting Uncertainty | <2% (statistical repeatability) |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ASTM D6786, NAVAIR 01-1A-17, GOST, HAL |
| Imaging Resolution | ≥20 µm for automated morphology classification |
| Ferrous Sensor Sensitivity | Sub-ppm detection limit for ferrous concentration |
| Analysis Time per Sample | ~4 minutes |
| Data Integration | Native export to SpectroTrack LIMS and AMS Asset Management System |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | MicroLab 30 |
| Detection Capabilities | Elemental Analysis (via Rotating Disc Electrode Atomic Emission Spectrometry), Infrared Spectroscopy, Kinematic Viscosity (at 40 °C and 100 °C), Acid Number, Oxidation, Nitration, Soot, Glycol, Water, Particle Count (optional module), Additive & Contaminant Elemental Profiling |
| Compliance | ASTM D7417 (Standard Test Method for Determination of Oxidation, Nitration, Soot, Glycol, Water, and Elemental Composition in Used Lubricating Oils Using Fourier Transform Infrared (FTIR) Spectroscopy, Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES), and Kinematic Viscosity) |
| Software | Embedded Expert System with >10,000 rule-based diagnostic scripts |
| Sample Throughput | ~15 minutes per sample (full suite of ASTM D7417–compliant tests) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | Minilab 153 |
| Detection Capabilities | Elemental Analysis (24 elements standard, up to 31), Particle Counting, Ferrous Particle Quantification (ppm) & Size Distribution, Kinematic Viscosity at 40 °C, TAN/TBN, Oxidation/Sulfation/Nitration, Water Content, Glycol, Soot |
| Software Platform | TruVu 360 Oil Intelligence Platform |
| Compliance | Designed for ASTM D6595 (rotary disc electrode emission spectroscopy), ISO 4406 (particle contamination), ASTM D2440 (TAN), ASTM D974 (TBN), ASTM D2896 (TBN), ASTM D7945 (viscosity), and supports GLP/GMP audit trails per FDA 21 CFR Part 11 requirements |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | SpectroTrack |
| Architecture | Browser-based (B/S) |
| Compliance | Designed for ISO/IEC 17025, ASTM D6595, D7684, D7690, and FDA 21 CFR Part 11-ready workflows |
| Integration | Native support for Spectro Scientific analyzers including Spectroil Q100, LNF-Q200, SpectroVISC, and FluidScan platforms |
| Deployment | On-premise or secure cloud-hosted |
| User Access | Role-based authentication with audit trail logging |
| Data Handling | Structured metadata capture for samples, assets, instruments, clients, and test methods |
| Reporting | Automated PDF/Excel report generation with customizable templates |
| Trending | Time-series analysis of elemental concentrations, viscosity, oxidation, nitration, soot, water, and particle counts |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58C |
| Product Type | Portable Instrument |
| Detection Modules | XRF Elemental Analysis |
| Test Time per Sample | <10 minutes |
| Sample Volume Required | 12 mL |
| Compliance | ASTM D6595, D7690, D7883, D445 |
| Interface | Touchscreen with Embedded Diagnostic Software |
| Power | Rechargeable Battery |
| Enclosure | Ruggedized Transport Case Integrating All Four Modules |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | SpectrOil 120C |
| Detection Principle | Rotating Disc Electrode (RDE) Atomic Emission Spectrometry |
| Compliant Standards | ASTM D6595 (Used Lubricants), ASTM D6728 (Fuel Oils) |
| Sample Volume | 2 mL |
| Analysis Time | ≤30 seconds per sample |
| Elements Quantified | Up to 31 elements (24 standard + 7 optional) |
| Detection Limits | Sub-ppm for most metallic elements |
| Sample Preparation | None — direct oil injection |
| Gas Requirement | None |
| Application Scope | In-service lubricant wear debris, contaminant, and additive analysis |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FluidScan |
| Product Type | Portable Instrument |
| Detection Parameters | Contaminants, Oxidation, Acid Number (AN), Base Number (BN), Water Content (Free & Dissolved), Fluid Identity |
| Compliance | ASTM D7889, JOAP Standards |
| Measurement Principle | Mid-Infrared (MIR) Absorption Spectroscopy |
| Sample Volume | 1 Drop (~50 µL) |
| Analysis Time | ≤ 60 Seconds |
| Onboard Database | > 800 Lubricant & Grease Reference Spectra |
| Calibration | Factory-Calibrated with Industry-Validated Algorithms |
| Reporting | Automated PDF Report Generation |
| Software Integration | FluidScan Manager (Windows-based Database & Trending Software) |
| Regulatory Support | Audit Trail, User Access Control, Data Export for GLP/GMP Environments |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | Microlab 40 |
| Application | Elemental Analysis, Particle Counting, Viscosity, Oxidation/Nitration/Total Base Number (TBN), Coolant & Water Contamination, Soot Measurement |
| Compliance | ASTM D6595 (Rotary Disc Electrode Emission Spectrometry), ASTM D7690 (Automatic Particle Counting), ASTM D445 (Kinematic Viscosity), ASTM D2896/D4739 (TBN), ISO 4406:2017 (Particle Contamination Code) |
| Configuration | Benchtop, Integrated Lab-Scale Analyzer for On-Site or Centralized Lubricant Diagnostics |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FerroCheck 2000 |
| Type | Portable Instrument |
| Compliance | ASTM D8120 |
| Detection Principle | Magnetic Susceptibility-Based Impedance Measurement |
| Sample Volume | 1.5 mL (oil), 0.75 mL (grease) |
| Analysis Time | ≤30 s |
| Detection Limit | <3 ppm Fe |
| Repeatability | ±2% RSD |
| Power | Rechargeable Li-ion battery (4 h runtime) |
| Data Output | CSV, AMS OilView-compatible |
| Calibration | Pre-loaded with certified calibration standards |
| Temperature Compensation | Automatic real-time coil current balancing |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | 120C |
| Application | Elemental Analysis of Lubricating Oils, Fuels, Coolants, and Industrial Fluids |
| Compliance | ASTM D6595, ASTM D6728 |
| Sample Volume | 2 mL |
| Analysis Time | ≤30 s per sample |
| Elements Quantified | Up to 31 metals |
| Detection Limits | Sub-ppm for most elements |
| Sample Preparation | Solvent-free, no dilution required |
| Configuration | Benchtop laboratory spectrometer |
| Intended Use | Wear debris monitoring, additive package verification, contamination screening |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FluidScan 1000 Series |
| Instrument Type | Portable Analyzer |
| Measurement Parameters | Water Content, TAN (Total Acid Number), TBN (Total Base Number), Oxidation, Nitration, Sulfation, Glycol, Soot, Additive Depletion, Overall Oil Health Index |
| Compliance | ASTM D7889, ASTM E2412, ASTM E1655 |
| Sample Volume | 1 drop (~50 µL) |
| Analysis Time | < 60 seconds per sample |
| Calibration Database | > 850 reference spectra (mineral & synthetic oils, greases, biodiesel, fuels) |
| Cleaning Method | Solvent-free |
| Detection Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Portability | Handheld, battery-operated, field-deployable |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Application Standard | DIN 51805 |
| Temperature Range | –60 °C to +30 °C |
| Temperature Accuracy | ±0.1 °C |
| Pressure Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W or 12 V DC / 10 A |
| Dimensions (W×H×D) | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Interface | RS232 |
| Display Languages | English, German |
| Cooling Method | Peltier-based |
| Sample Compatibility | NLGI Grades 000–3 Greases |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FDM 6000 |
| Type | Portable Instrument |
| Detection Principle | Surface Acoustic Wave (SAW) Sensor Technology |
| Measurement Range | 0.2–15% fuel dilution (v/v) |
| Repeatability | ≤5% RSD |
| Analysis Time | ≤120 seconds per sample |
| Sample Volume | <1 mL |
| Power Source | Rechargeable lithium-ion battery |
| Data Storage | Up to 3 calibration curves |
| Display | Color touchscreen interface |
| Compliance | Designed for ASTM D7943-22 and ISO 4406-aligned maintenance practices |
| Software Guidance | Multilingual audio-assisted operation (including English voice prompts) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | N99903 |
| Application | Elemental analysis of engine coolants (antifreeze), lubricating oils, fuel oils, and greases |
| Measurement principle | Rotating Disc Electrode (RDE) atomic emission spectroscopy |
| Analysis time | ≤30 seconds per sample |
| Sample preparation | None required |
| Consumables | No carrier gas required |
| Element count | Up to 13 elements simultaneously quantifiable in coolant matrices |
| Compliance | Designed for ASTM D6595-compliant operation |
| Instrument class | Benchtop laboratory spectrometer |
| Regulatory context | Supports GLP/GMP data integrity requirements via audit-trail-capable software |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FluidScan 1000 |
| Instrument Type | Portable Infrared Spectrometer |
| Compliance | ASTM D7889, ASTM E2412, ASTM E1655 |
| Detection Targets | Water, TAN (Total Acid Number), TBN (Total Base Number), Oxidation, Nitration, Sulfation, Glycol, Soot, Additive Depletion, Contamination Index |
| Sample Volume | 1 drop (~50 µL) |
| Analysis Time | < 60 seconds per sample |
| Calibration Database | > 850 reference oils |
| Lubricant Compatibility | Mineral & synthetic engine oils, gear oils, turbine oils, hydraulic fluids, transmission fluids, greases, biodiesel, and fuel blends |
| Cleaning Method | Solvent-free |
| Measurement Principle | Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) Spectroscopy |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | SpectrOil M/N-W |
| Application | Elemental Analysis of In-Service Lubricants, Hydraulic Fluids, and Coolants |
| Certification | Qualified under U.S. Department of Defense Joint Oil Analysis Program (JOAP) CID-0191 |
| Element Capacity | 15 or 20 elements (JOAP-compliant configurations) |
| Measurement Principle | Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES) |
| Sample Throughput | ~30 seconds per analysis |
| Power Requirement | Standard AC mains (100–240 VAC, 50/60 Hz) |
| Form Factor | Benchtop, transportable |
| Compliance | JOAP-certified consumables and calibration protocols required for data traceability |