| Brand | CHEMn |
|---|---|
| Origin | Anhui, China |
| Model | TFD-1200-50-II-200-RZ |
| Max Temperature | 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 1.5 kW |
| Heating Rate (to Max Temp) | ≤10 °C/min |
| Heating Method | Resistance Wire Heating |
| Chamber Configuration | Dual Independent Temperature Zones (ΔT ≤ 200 °C) |
| Internal Dimensions | Customizable |
| Instrument Type | Vertical Lift-Type TGA Furnace |
| Core Function | High-Temperature Atmosphere-Controlled Mass Change Monitoring |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | TFG-1200-50-I-220 |
| Instrument Type | Vertical Tube Furnace |
| Max Temperature | 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 2.0 kW |
| Heating Rate (to Max Temp) | ≤10 °C/min |
| Heating Method | Resistance Wire |
| Internal Chamber Dimensions | 660 × 320 × 580 mm |
| Tube ID × Length | 50 × 450 mm |
| Sample Boat Capacity | 10 mL (customizable) |
| Sample Boat Diameter | 30 mm |
| Heated Zone Length | 220 mm |
| Mass Flow Range (Rotameter) | 30–200 mL/min (customizable) |
| Control System | Dual-Channel Intelligent Programmable Controller with Color Touchscreen |
| Power Supply | AC 220 V, 50/60 Hz |
| Weight | 35 kg |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | SCH-PCRS-8-427-K |
| Cooling Capacity | 130–445 W |
| Heating Method | Ceramic Fan Heater |
| Cooling Method | DC Inverter Compressor (R134a) |
| Temperature Control Range | 10–50 °C |
| Temperature Stability | ±0.2 °C |
| Stirring Mode | Direct-Drive Rare-Earth Permanent Magnet Motor |
| Stirring Speed | 150–1000 rpm, Continuously Adjustable |
| Light Source Interface | 24 V / 8 A DC Output |
| Standard Reaction Stations | 12 (3 × 4 configuration) |
| Dimensions (W×D×H) | 420 × 470 × 550 mm |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FLB-4 |
| Price Range | USD 2,800 – 7,000 (FOB) |
| Chamber Capacity | Small-scale (≤50 mL typical use) |
| Operating Pressure | Low-pressure ambient environment |
| Vacuum Capability | Not applicable |
| Structural Material | Anodized aluminum housing with borosilicate glass viewport |
| Cooling System | Dual axial fans (rear-mounted, thermostatically regulated) |
| LED Mounting | Four fixed-position Kessil A365/A400-series compatible sockets (M4 threaded, 12 V DC input) |
| Power Input | 100–240 V AC, 50/60 Hz |
| IP Rating | IP20 (indoor laboratory use only) |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | TFH-1500-50-I-400 |
| Max Temperature | 1500 °C (short-term), 1400 °C (rated) |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 6 kW |
| Heating Rate | ≤10 °C/min (up to 1400 °C) |
| Heating Element | SiC Rods |
| Internal Dimensions | 670 × 580 × 750 mm |
| Tube Diameter | φ50 mm or φ60 mm × 1000 mm (customizable) |
| Heating Zone Length | 390 mm |
| Control System | Yudian AI-3756P touchscreen controller with 30-segment programmable PID, fuzzy logic auto-tuning, over-temperature & thermocouple failure alarms |
| Thermocouple Type | S-type |
| Vacuum/Atmosphere Compatibility | Yes (with 316L stainless steel quick-release flanges and dual-ring sealing) |
| Cooling | Dual-layer forced-air cooling (surface temp ≤60 °C) |
| Weight | 75 kg |
| Power Supply | AC 220 V, 50/60 Hz |
| Brand | Chemn |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CFRF-L1G3-600-100 |
| Reaction Pressure | 10 MPa |
| Maximum Reaction Temperature | 800 °C |
| Catalyst Loading Capacity | 0.5–5 mL |
| Heating Configuration | Triple-Zone Electric Furnace (for floor-standing unit) / Oil-Jacketed Bath (for benchtop unit, max 300 °C) |
| Display | 10.1" TFT Touchscreen HMI |
| Remote Control | Yes, via PC-based SCADA software |
| Safety Features | Dual-stage over-temperature/over-pressure interlock, combustible gas monitoring, automatic shutdown |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | TFD-1100-70-RZ |
| Max Temperature | 1100 °C |
| Rated Temperature | 1000 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Rate (to max temp) | ≤10 °C/min |
| Heating Method | Resistive Wire Heating |
| Internal Dimensions | 800 × 500 × 1550 mm |
| Tube Dimensions | φ70 × φ50 × 350 mm (customizable) |
| Heating Zone Length | 220 mm |
| Rated Power | 3.5 kW |
| Dual-Zone Variant Power | 4.5 kW |
| Dual-Zone Heating Length | 2 × 200 mm |
| Gas Flow Control | Two Mass Flow Controllers (N₂ & CO₂, 0–2 SLM each) |
| Balance Range | 0–220 g |
| Balance Readability | 0.1 mg |
| Cooling | Dual-layer forced-air cooling |
| Surface Temperature | ≤60 °C |
| Temperature Programming | 30-segment programmable controller (Yudian PID with K-type thermocouple) |
| Brand | Chemn |
|---|---|
| Origin | Anhui, China |
| Model | NS6-20D-SS1-P3-T2 |
| Vessel Capacity | 10 mL & 20 mL per station |
| Design Pressure | 10 MPa (100 bar) |
| Design Temperature | 200 °C |
| Construction Material | 316L Stainless Steel & Hastelloy C-276 |
| Heating Method | Embedded Aluminum Sleeve Heater |
| Stirring Mechanism | Magnetic Stirring |
| Speed Range | 100–1200 rpm |
| Control Interface | 7-inch HD Touchscreen with PID Temperature Control & Stepless Speed Regulation |
| Pressure Monitoring | Yaskawa (USA) Pressure Gauge (optional pressure transmitter) |
| Safety Valves | Fitok (USA) Relief Valve & Rupture Disc |
| Gas Inlet/Outlet Valves | Swagelok (USA) Needle Valves |
| Power Supply | 200–240 V AC, 50–60 Hz |
| Controller Dimensions | 260 × 470 × 260 mm (L×D×H) |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | SLS-LED-80A |
| Light Source Type | High-Power Broadband LED Array |
| Illumination Mode | External Irradiation |
| Spectral Range | 400–800 nm |
| Spectral Match Class | ASTM E927-22 Class A |
| Spatial Uniformity Class | ASTM E927-22 Class A |
| Temporal Stability Class | ASTM E927-22 Class A |
| Effective Illuminated Area | Ø80 mm |
| Irradiance Range | 0–2.1 suns (AM1.5G, 100 mW/cm² equivalent) |
| Rated Lifetime | >10,000 h (L70) |
| Beam Orientation | Fully Adjustable (Pitch/Yaw/Roll via Integrated Goniometric Mount) |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | NSI |
| Vessel Capacity | 10–1000 mL |
| Design Pressure | 35 MPa |
| Design Temperature | 500 °C |
| Construction Material | 316L Stainless Steel (standard), Hastelloy C-276 (optional) |
| Heating Method | Embedded stainless steel heating module |
| Stirring Speed Range | 100–1200 rpm |
| Control Interface | 7-inch capacitive touchscreen |
| Data Export | USB port |
| Safety Systems | MEAS pressure transducer, Ashcroft analog pressure gauge, Swagelok inlet/outlet needle valves, FITOK safety relief valve, custom rupture disc, over-temperature cut-off, over-pressure audible alarm |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | TFP-1200-51-I-440-NH3 |
| Max. Temperature | 1000 °C |
| Temp. Control Accuracy | ±1 °C |
| Max. Power | 1.5 kW |
| Heating Rate (to max temp) | 10 °C/min |
| Heating Element | MoSi₂ (1800-grade) |
| External Dimensions | 1250 × 650 × 1330 mm |
| Tube ID/OD/Length | Ø45 / Ø51 / 1000 mm |
| Tube Material | GH202 nickel-based superalloy |
| Max. Operating Pressure | 10 MPa (≤800 °C) |
| Pressure Monitoring | Dual 0–16 MPa transducers + triple mechanical gauges |
| Gas Flow Control | Inlet MFC (0–500 sccm), Outlet MFC (0–1000 sccm) |
| Oxygen Detection | 0–1000 ppm trace O₂ analyzer (H₂-compatible) |
| Safety | High-temp solenoid valve (15 MPa rating), audible overpressure alarm, NH₃-specific exhaust scrubber |
| Brand | CHEMn |
|---|---|
| Origin | Anhui, China |
| Model | TFH-1200-50-III-200 |
| Maximum Temperature | 1200 °C (short-term) |
| Rated Operating Temperature | 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Zones | 3 independent zones (each 200 mm) |
| Uniform Temperature Zone Length | 400 mm |
| Tube Dimensions | Φ50 mm (OD) × 1000 mm (L) |
| Chamber Internal Dimensions | 1350 × 420 × 520 mm |
| Max. Power Consumption | 6 kW |
| Ramp Rate to Max Temp | ≤10 °C/min |
| Heating Element | HRE resistance wire (Shougang, Beijing) |
| Insulation Material | High-purity alumina microcrystalline fiber, vacuum-formed |
| Cooling System | Dual-layer forced-air cooling |
| Surface Temperature | ≤60 °C |
| Control System | Yudian AI-3756P 7-inch color touchscreen controller with 30-segment programmable ramp-soak profiles |
| Temperature Sensor | K-type thermocouple |
| Atmosphere Compatibility | Vacuum and inert/reducing/reactive gas environments (via quartz tube + stainless steel flanges) |
| Data Interface | USB port for real-time data logging and export |
| Brand | CHEMn |
|---|---|
| Origin | Anhui, China |
| Model | TFG-1200-100-II-300 |
| Max. Operating Temperature | 1200 °C |
| Max. Working Pressure | 100 kPa (gauge) |
| Catalyst Loading Capacity | Customizable |
| Compliance | Designed for laboratory-scale catalyst activation under controlled atmospheres |
| Brand | Chemn |
|---|---|
| Origin | Anhui, China |
| Model | TFG-1200-50-220 |
| Instrument Type | Vertical Tube Furnace |
| Max. Temperature | 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Max. Power | 2.0 kW |
| Heating Rate (to Max Temp) | ≤10 °C/min |
| Heating Method | Resistance Wire |
| Internal Chamber Dimensions | 660 × 320 × 580 mm |
| Tube Diameter | 30 mm |
| Sample Boat Capacity | 10 mL (customizable) |
| Heating Zone Length | 220 mm |
| Mass Flow Range (Rotameter) | 30–200 mL/min (customizable) |
| Control System | Dual-Channel Intelligent Programmable Controller with Color Touchscreen |
| Power Supply | AC 220 V, 50/60 Hz |
| Weight | 35 kg |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | TFE-1200-50-I-220 |
| Maximum Operating Temperature | 1150 °C (short-term), 1100 °C (rated) |
| Temperature Control Accuracy | ±1 °C |
| Heating Zone Length | 220 mm |
| Uniform Temperature Zone Length | 80 mm |
| Tube Dimensions | Φ30/50/60 × 1200 mm |
| Furnace Chamber Diameter × Height | Φ80 × 220 mm |
| RF Power Range | 5–500 W |
| RF Frequency | 13.56 MHz |
| Gas Delivery | 3-channel MFC-controlled (0–500 sccm per channel, customizable) |
| Vacuum System | Dual-stage rotary vane pump (optional diffusion or turbomolecular pump upgrade) |
| Rated Heating Power | 3 kW |
| Recommended Ramp Rate | ≤10 °C/min |
| External Dimensions | 1250 × 510 × 810 mm |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | MSP |
| Reactor Volume Options | 25 mL, 50 mL, 100 mL, 300 mL, 500 mL, 1000 mL |
| Construction Material | Stainless Steel (316L standard) |
| Maximum Operating Pressure | 345 bar (5000 psi) |
| Sealing System | Dual-seal configuration — reinforced PTFE gaskets ≤300 °C |
| Vacuum Capability | Up to −0.098 MPa (equivalent to ~20 mbar abs) |
| Heating Method | Integrated steel-sheathed resistive furnace with overheat protection |
| Control Architecture | Siemens S7-1200 PLC + Schneider safety relays |
| Temperature Control Precision | ±1 °C (typical, full range) |
| Stirring Drive | Patented high-torque magnetic coupling, fully static seal |
| Compliance | Designed per ISO 4775, ASME BPVC Section VIII Div. 1 (for rated pressure variants), CE-marked for laboratory equipment |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | BEC-1500-8L |
| Max Temperature | 1400 °C |
| Temperature Uniformity | ±1 °C |
| Rated Power | 5.2 kW |
| Heating Rate | 10 °C/min (≤1400 °C) |
| Heating Element | 1500-grade U-shaped SiC rods |
| Internal Dimensions | 180 × 250 × 180 mm |
| Chamber Volume | 8 L |
| Control System | 30-segment programmable fuzzy PID with auto-tuning, over-temperature & thermocouple break protection |
| Voltage | AC 220 V, 50/60 Hz |
| External Dimensions | 590 × 580 × 780 mm |
| Net Weight | 80 kg |
| Brand | Chemn |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Equipment Type | Box-Type Muffle Furnace |
| Model | BFC-1200-1L |
| Maximum Temperature | 1200 °C (short-term), 1000 °C (continuous) |
| Temperature Uniformity | ±1 °C |
| Rated Power | 1 kW |
| Heating Rate to Max Temp | 10 °C/min |
| Heating Method | Resistive Wire (HRE Alloy, Beijing Shougang) |
| Chamber Dimensions | 100 × 100 × 100 mm (1 L nominal volume) |
| Thermocouple Type | K-type |
| Input Voltage | AC 220 V, 50/60 Hz |
| External Dimensions | 290 × 270 × 450 mm |
| Net Weight | 14 kg |
| Brand | CHEMn |
|---|---|
| Model | NSG |
| Origin | Anhui, China |
| Reactor Volume Options | 10, 25, 50, 100, 300, 500, 1000 mL |
| Design Temperature | 500 °C (Standard Heating up to 300 °C) |
| Maximum Working Pressure | 35 MPa (Optional) |
| Standard | 20 MPa (for 25–100 mL), 10 MPa (for 300–1000 mL) |
| Construction Material | 316L Stainless Steel or Hastelloy C-276 (Optional) |
| Stirring Speed Range | 100–1200 rpm |
| Heating Method | Embedded Stainless Steel Heating Module |
| Heating Power | 1 kW |
| Vacuum Capability | Up to 35 MPa (Note: This value reflects maximum rated pressure |
| assumed typo — corrected to “Rated Pressure | 35 MPa”) |
| Control Interface | 7-inch capacitive touchscreen |
| Data Export | USB-based real-time logging and report generation |
| Safety Systems | Dual-pressure protection (Fitok needle valves, certified safety valve + custom rupture disc), over-temperature cutoff, over-pressure audible alarm |
| Sealing | Tongue-and-groove main seal |
| Stirring Mechanism | Internal magnetic stir bar (PTFE-, glass-, or metal-core options available) |
| Brand | Chemn |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MSI-16 |
| Instrument Category | High-Pressure Reaction Vessel |
| Vessel Material | 316L Stainless Steel (standard), Hastelloy C-276 (optional) |
| Working Pressure | Up to 35 MPa (optional), 20 MPa (standard for 25–100 mL), 10 MPa (standard for 300–500 mL) |
| Volume Options | 25 mL, 50 mL, 100 mL, 300 mL, 500 mL |
| Operating Temperature Range | Ambient to 550 °C (standard configuration: up to 300 °C) |
| Stirring Speed | 100–1200 rpm (100–600 rpm above 350 °C) |
| Heating Method | Embedded stainless-steel heating module |
| Stirring Mechanism | High-torque magnetic coupling or internal magnetic stir bar |
| Pressure Sensing | MEAS or ISE pressure transducers |
| Control Interface | 10-inch high-resolution capacitive touchscreen with real-time display of temperature, pressure, stirring speed, and elapsed time |
| Data Export | USB port for CSV log export (temperature, pressure, rpm, timestamp) |
| Safety Features | Over-temperature automatic power cutoff, over-pressure audible alarm, tongue-and-groove sealing structure, monolithic machined body |
| Dimensions (W×D×H) | 1050 × 600 × 650 mm |
| Compliance | Designed per ASME BPVC Section VIII Div. 1 guidelines for pressure containment |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | TFH-1700-25-290 |
| Maximum Temperature | 1700 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Power | 5.5 kW |
| Heating Rate | ≤10 °C/min (≤1400 °C), ≤5 °C/min (1400–1600 °C), ≤2 °C/min (>1600 °C) |
| Heating Element | Grade-1800 Molybdenum Disilicide (MoSi₂) Rods |
| Tube Dimensions | OD 25 mm × ID 19 mm × L 1000 mm (customizable) |
| Heating Zone Length | 290 mm |
| Thermocouple Type | Type B (Platinum-Rhodium) |
| Control System | 30-Stage Programmable PID with Auto-Tuning, Touchscreen HMI (Yudian AI-3756P, 7″ color) |
| Cooling Design | Dual-layer air-cooled housing, surface temperature ≤60 °C |
| Insulation | Dual-layer high-purity polycrystalline mullite fiber vacuum-formed chamber |
| Vacuum/Atmosphere Compatibility | Equipped with quick-release flanges, needle valves, analog vacuum gauges, and standard hose ports (upgradable to KF-25 or 1/4″ VCR fittings) |
| Data Interface | USB real-time data export, optional PC software for live monitoring (separately ordered) |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MSD2L-SS1-L1G2 |
| Reactor Type | High-Pressure Batch Reactor |
| Vessel Volume Options | 300 mL, 2 L, 5 L, 10 L |
| Design Pressure | 10 MPa |
| Design Temperature | 300 °C |
| Construction Material | Stainless Steel (SS316L standard) |
| Stirring Mechanism | Magnetic Coupling Drive with Propeller or Anchor Impeller (Single- or Dual-Stage) |
| Gas Inlet Control | Constant-Flow or Constant-Pressure Mode |
| Liquid Dosing | Anhydrous/Oxygen-Free Injection via Septum or Valve-Isolated Port |
| Vacuum Capability | ≤10⁻³ mbar (with optional vacuum pump interface) |
| Pressure Monitoring | WIKA Bourdon Tube Gauge + MEAS 4–20 mA Pressure Transmitter |
| Temperature Monitoring | Dual Pt100 RTD Sensors (Jacket & Internal) |
| Heating Method | Electric Cartridge Heaters or External Oil Circulator Interface |
| Safety Systems | Rupture Disk + Spring-Loaded Safety Valve + Redundant Interlock Logic (Temperature/Pressure/Combustible Gas Detection) |
| Data Acquisition | 10.2″ HMI Touchscreen with Local Historian |
| Sampling | Integrated Quenchable Liquid Sampling Loop with Cryo-Trap and Inert Gas Purge |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | NVG (General), NVI (Intelligent), NVP (Remote-Controlled) |
| Vessel Capacity | 25–500 mL |
| Maximum Operating Pressure | 10 MPa |
| Maximum Operating Temperature | 300 °C |
| Construction Material | SS316L (standard), optional Hastelloy C-276, TA2, Zr702 |
| Stirring Speed Range | 100–1200 rpm |
| Heating Method | Integrated stainless steel heating module (1 kW) |
| Optical Window | Sapphire crystal (26 mm dia. for 25–50 mL |
| Sealing System | Radial + axial dual-seal with Kalrez® perfluoroelastomer O-rings |
| Pressure Monitoring | MEAS sensor (NVI/NVP), digital pressure gauge (ASHCROFT/Fitok) |
| Safety Features | Rupture disc, safety valve (Fitok), overpressure audible alarm (NVI/NVP) |
| Remote Interface | NVP supports local touchscreen, PC-based control, and mobile app via secure IoT protocol |
| Compliance | Designed for GLP-compliant photochemical synthesis workflows |
| Brand | Chemn |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HTG / HTS |
| Volume Options | 10, 25, 50, 100, 150, 200, 300, 500, 1000 mL |
| Max Operating Temperature | 220 °C (domestic PTFE) / 260 °C (imported PTFE) |
| Max Working Pressure | 3 MPa |
| Vacuum Rating | 30 bar |
| Heating Compatibility | Oven, Oil Bath, Electric Heater |
| Liner Material | High-Purity Polytetrafluoroethylene (PTFE) |
| Vessel Body Material | Stainless Steel (AISI 304 or 316 optional) |
| Pressure Class | Low-Pressure Reactor (ASME B16.5 compliant for flanged variants) |