Empowering Scientific Discovery

Anhui Wanyi Science & Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (PRC)
ModelModular Differential Pressure Airtightness Leak Tester
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOEM Manufacturer
Origin CategoryDomestic (China)
ModelZH600-X Multi-Station Hermeticity Leak Detector
PricingAvailable Upon Request
Pressure Sensor Range (ZH600-X)10–500 kPa (mechanically regulated)
Sensor Accuracy±0.1% FS
Display ResolutionAdjustable to 0–4 decimal places
Pressure UnitskPa, MPa, kg/cm², psi, mbar, bar, Torr, mmH₂O, mmHg
Leak Rate UnitsPa, kPa, Pa/s, kPa/s, kPa/min, mL/s, mL/min, mL/h, L/min, L/h, SCCM
Programmable Test Profiles64 total (16 per channel across A/B/C/D channels)
Test Cycle Time0–999 s (max test duration: 1800 s)
Power SupplyAC 220 V ±10%, 50 Hz
Required Test Gas SourceClean, dry, ≥500 kPa supply pressure, ≥100 kPa above test pressure
Dimensions (ZH600-X)431 × 187 × 460 mm
Weight~14 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of ManufactureChina
ModelSFJ-16C / SFJ-16D
Base PumpRotary Vane Vacuum Pump (SFJ-16C) / Scroll Vacuum Pump (SFJ-16D)
Minimum Detectable Leak Rate (Vacuum Mode)5.0 × 10⁻¹³ Pa·m³/s
Minimum Detectable Leak Rate (Sniffer Mode)2.5 × 10⁻⁹ Pa·m³/s
Maximum Allowable Test Pressure1800 Pa
Human-Machine Interface7-inch Color TFT LCD Touchscreen
Leak Port ConnectionDN25 KF
Dimensions (W×D×H)475 × 714 × 1168 mm
Power SupplyAC 220 V (±10%), 50/60 Hz
Response Time<1 s
Pump-Down/Startup Time<95 s
Detectable Massesm/z = 2 (H₂), 3 (³He), 4 (⁴He)
Ion SourceDual Filament, Yttria-Coated Iridium, Auto-Switching
I/O InterfacesRS-232, RS-485, LAN, MES Integration Ready
Operating Temperature0–40 °C
Display LanguagesEnglish & Chinese
Leak Rate VisualizationNumeric Value, Bar Graph, Real-Time Trend Curve
ComplianceDesigned for ISO 10110-7, ASTM E1003, and JIS Z 2301 aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelSFJ-16C/D
PricingUpon Request
Base Pump (SFJ-16C)Rotary Vane Vacuum Pump
Base Pump (SFJ-16D)Scroll Vacuum Pump
Minimum Detectable Leak Rate (Helium Mode, Vacuum Method)5.0 × 10⁻¹³ Pa·m³/s
Minimum Detectable Leak Rate (Helium Mode, Sniffer Method)2.5 × 10⁻⁹ Pa·m³/s
Maximum Allowable Test Pressure1800 Pa
Human-Machine Interface7-inch Color LCD Touchscreen
Leak Port FlangeDN25 KF
Dimensions (W × D × H)475 × 714 × 1168 mm
Power SupplyAC 220 V (±10%), 50/60 Hz
Response Time<1 s
Pump-Down / Startup Time<95 s
Detectable Massesm/z = 2 (H₂), 3 (³He), 4 (⁴He)
Ion SourceDual Filament, Yttrium Oxide-Coated Iridium, Auto-Switching
I/O InterfacesRS232, RS485, LAN
MES IntegrationStandard
Operating Temperature Range0–40 °C
Display LanguagesEnglish & Chinese
Leak Rate VisualizationNumeric, Bar Graph, Real-Time Trend Curve
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (PRC)
ModelHigh-Capacity Direct-Pressure Helium Leak Detector
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelHigh-Precision Differential Pressure Leak Tester
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelLC103(V5) / LC101(V6) Wide-Range Flow-Based Leak Detector
Price RangeUSD 14,000 – 28,000
Flow Range30–1000 mL/min (selectable)
Pressure RegulationMechanical, 10–600 kPa (selectable)
Test Pressure UnitskPa, MPa, kg/cm², psi, mbar, bar, Torr, mmH₂O, mmHg
Leak Rate UnitsmL/s, mL/min, L/min, L/h, m³/h, Pa/min, g/h, SCCM
Display ResolutionAdjustable to 0–4 decimal places
Sensor Accuracy±3% F.S. (LC103 V5), ±0.1% F.S. (LC101 V6)
Programmable Test Profiles64 sets
Test Cycle Timing0–999 s
Max Test Duration1800 s
Power SupplyAC 220 V ±10%, 50 Hz
Required Test Gas SourceClean, dry, ≥500 kPa supply pressure, at least 100 kPa above test pressure
Dimensions (V5)330 × 222 × 448 mm
Dimensions (V6)321 × 205 × 460 mm
Weight~16 kg