BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelPA2000
Instrument TypePortable
Detection PrincipleCatalytic Oxidation + Flame Ionization Detection (FID)
Regulatory ComplianceHJ 1012–2018
Detection LimitSub-ppb (NMHC)
Analysis CycleAs low as 5 seconds
Operating TemperatureFull-path high-temperature heating (≥180 °C)
Methane Separation MethodHigh-efficiency catalytic oxidation (≥98% conversion efficiency)
Catalyst Lifetime≥3 years
Oxygen MeasurementIntegrated paramagnetic/O₂ sensor
Weight~13 kg
Carrier GasNot required
Combustion AirBuilt-in compressor — no external air supply needed
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM/ODM)
Country of OriginChina
ModelAQ7100
PricingAvailable upon Request
Measured ParametersSO₂, NO₂, CO, O₃, PM₂.₅, PM₁₀, TVOC, Temperature, Relative Humidity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelLD1200A
PricingUpon Request
Measurement PrincipleLaser Forward Light Scattering
Safety RatingNon-Explosive
Measurement Range0–15 mg/m³
Resolution0.1 mg/m³
Accuracy±10% of reading
Relative Error±2%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelAQ7800
Instrument TypeOnline Fixed-Station Analyzer
Detection PrincipleGas Chromatography with Flame Ionization Detection (GC-FID)
Measurement MethodDirect Analysis (Non-Preconcentration Bypass Mode with Cold Trap Preconcentration Option)
Detection Limit≤1 ppbC (as Carbon)
ComplianceHJC-ZY84-2020
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
ManufacturerWAYEAL Instrument Co., Ltd.
ModelWS1801
Instrument TypeOnline Automatic Water Sampler
Sampling MethodExceedance-triggered Retention Sampling
Single Sample Volume10 mL to 1000 mL
Sampling Volume Accuracy±7% (at 200 mL retention volume)
Sampling IntervalAdjustable from 1 min to 9999 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelWMS1800
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelVM1700
Instrument TypeOnline Continuous Emission Monitoring System (CEMS)
Detection PrincipleGas Chromatography–Flame Ionization Detection (GC-FID)
Target AnalytesMethane (CH₄), Total Hydrocarbons (THC), Non-Methane Hydrocarbons (NMHC), and selected BTEX compounds
Sample Path Temperature175 °C (fully heated from probe to detector)
ComplianceCertified by China National Environmental Monitoring Centre (CNEMC) for CEMS applicability testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelCEMS 1200
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement Accuracy≤ ±5% FS
Repeatability≤ 1% FS
Response Time≤ 90 s
Drift Stability≤ 1% FS over 7 days
Measured ParametersSO₂, NOₓ (NO + NO₂), O₂, CO, CO₂, HCl, particulate matter (PM) concentration, flue gas velocity, static pressure, relative humidity, emission rate, and cumulative emissions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelWS1504
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelCEMS1250
Instrument TypeFlue Gas Continuous Emission Monitoring System
Measurement Accuracy±2.5% FS
Repeatability±2% FS
Response Time200 s
Long-term Stability±5% FS
Measured ParametersSO₂, NO, O₂, Particulate Matter (PM) Concentration, Flue Gas Temperature, Pressure, Velocity, Relative Humidity
Derived OutputsEmission Rate, Total Emissions
Sampling MethodDirect Extraction with Cold-Dry Conditioning
Certified Low-Range QuantificationSO₂ & NO at 0–45 mg/m³
PM Detection PrincipleLaser Forward Scattering
PM Certified Range0–15 mg/m³
ComplianceMeets Chinese HJ 75–2017 and HJ 76–2017 Technical Specifications for CEMS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Region ClassificationDomestic (China)
ModelWS1503
Price RangeUSD 7,000 – 14,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelWS1505
PricingUpon Request
Measurement MethodAlkaline Potassium Persulfate Digestion – UV Spectrophotometry
Measurement Range0–200.0 mg/L (expandable)
Accuracy±5%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelCEMS1200
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measured ParametersSO₂, NOₓ (NO, NO₂), O₂
Measurement Principle (O₂)Electrochemical Sensor
Measurement Principle (Temperature)PT100 or Thermocouple Sensor
Measurement Principle (Pressure)Piezoresistive Pressure Transducer
Measurement Principle (Flow Velocity)Pitot Tube
Measurement Principle (Humidity)High-Temperature Capacitive Hygrometer
Sampling MethodDirect Extraction – Hot/Wet Method
Certified SO₂ Range0–70 mg/m³
Certified NO Range0–65 mg/m³
Particulate Matter MethodLaser Forward Scattering
Certified PM Range0–15 mg/m³
Data InterfaceModbus RTU/TCP, OPC UA, 4–20 mA, RS-232/485
Compliance SupportGB/T 16157, HJ 75–2017, HJ 76–2017, ISO 12039, EN 15267
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelWMS1800x
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelVM1750
Instrument PrincipleCryogenic Preconcentration Coupled with Gas Chromatography–Mass Spectrometry (GC-MS)
ConfigurationOnline Continuous Monitoring System
Response Time≤5 s (T90)
Target Analytes116 VOCs including PAMS, TO-14/TO-15 compounds, and C1–C10 aldehydes & ketones
Detection CapabilitySub-ppt (pg/m³) level quantification
Detector ConfigurationDual-channel detection via Flame Ionization Detector (FID) and Quadrupole Mass Spectrometer (MS)
Sample IntroductionAutomated, unattended, real-time ambient air sampling
Surface TreatmentFully passivated gas pathways (SilcoNert® or equivalent inert coating)
Compliance ReadinessDesigned to support EPA Method TO-14A, TO-15, ASTM D5504, and ISO 16017-1 workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelAQ7000
QuotationUpon Request
Monitored PollutantsSO₂, NO, NOₓ, CO, O₃, PM₂.₅, PM₁₀
Meteorological ParametersWind Speed, Wind Direction, Temperature, Relative Humidity, Atmospheric Pressure
Optional Add-onsRainfall, Noise Level, Solar Radiation
Data AcquisitionIntegrated Substation Data Logger with Standardized Digital Interfaces
Calibration SystemDynamic Calibrator and Zero Air Generator
Compliance FrameworkDesigned for alignment with HJ 653–2013, HJ 654–2013, ISO 20815, EPA Reference Methods (e.g., EQOA-0017 for PM₂.₅), and GLP/GMP-aligned data integrity practices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelWS1501
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelTOF2000
Instrument PrincipleSingle-Photon Ionization Time-of-Flight Mass Spectrometry (SPI-TOF-MS)
ConfigurationOnline Fixed/Mobile Deployment
Response TimeSub-second (≤1 s)
Analyte Capacity>300 Atmospheric Volatile Organic Compounds (VOCs)
Mass Resolution>2000 FWHM (Toluene)
Linear Dynamic Range4 orders of magnitude
Vacuum SystemTurbo-molecular pump cascade (3-stage) + backing mechanical pump
Ionization Source10.8 eV VUV lamp (soft ionization)
Mass AnalyzerOrthogonal acceleration reflectron TOF with second-order spatial and energy focusing
Detection ModeDirect ambient sampling, no pre-concentration or chromatographic separation required
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelCEMS1300
Instrument TypeContinuous Emissions Monitoring System (CEMS)
Measured GasesCO₂, SO₂, NO, NO₂
Detection PrincipleNon-Dispersive Infrared (NDIR) Spectroscopy
ComplianceCertified by China National Environmental Monitoring Centre (CNEMC) for Applicability Testing
Data OutputWet-base, dry-base, and normalized (e.g., 6% O₂) concentration values
CalibrationAutomated zero/span calibration with diagnostic and alarm functions
ConnectivityLAN-based distributed architecture with remote data access capability
Regulatory AlignmentDesigned to support compliance with China’s HJ 75–2017 and HJ 76–2017 standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelWS1506
Measurement PrinciplePotassium Permanganate Oxidation with ORP Endpoint Detection
Instrument TypeOnline Analyzer
Range0–25.0 mg/L (expandable)
Repeatability≤5% RSD
Accuracy±10% of reading
LOD≤1.5 mg/L
Resolution0.01 mg/L
Single Analysis Time30–9999 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelSG1500
Instrument TypePortable Flue Gas Analyzer
Measurement Accuracy±2% FS
Repeatability≤2% FS
Response Time≤90 s
Baseline Stability±2% FS over 24 h
Measured GasesSO₂, NO, O₂, NOₓ, NH₃
Optional ExtensionCO₂
Operating Temperature Range (Sampling Path)Up to 180 °C
Display7″ Color TFT Touchscreen
Data OutputUSB Export (1-min & 5-min Averaged Reports), Optional Thermal Printer Support
Compliance FeaturesBuilt-in Humidity Sensor (wet-to-dry basis conversion), Automatic Leak Check, Flow & Pressure Compensation, Dual-Range Selection for SO₂/NOₓ, Real-time Trend Plotting, GLP-Compliant Audit Trail Logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelCEMS1900
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement PrincipleFourier Transform Infrared (FTIR) Spectroscopy
Accuracy≤ ±2% of Full Scale (F.S.)
Response Time≤ 200 s (typical gases)
Thermal StabilityFull-path high-temperature conditioning at 180 °C
Measured GasesSO₂, NO, NO₂, NOₓ, NH₃, HCl, HF, O₂, CO, CO₂, CH₄, H₂O (wet/dry basis & normalized concentrations)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWAYEAL
OriginAnhui, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM/ODM)
Country of ManufactureChina
ModelNM1000
Instrument TypeOnline Environmental Noise Monitoring System
ComplianceGB 3096–2008, GB/T 3222–2009, IEC 61672-1:2013 Class 1, ISO 1996-1:2016, ISO 1996-2:2017