| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PA2000 |
| Instrument Type | Portable |
| Detection Principle | Catalytic Oxidation + Flame Ionization Detection (FID) |
| Regulatory Compliance | HJ 1012–2018 |
| Detection Limit | Sub-ppb (NMHC) |
| Analysis Cycle | As low as 5 seconds |
| Operating Temperature | Full-path high-temperature heating (≥180 °C) |
| Methane Separation Method | High-efficiency catalytic oxidation (≥98% conversion efficiency) |
| Catalyst Lifetime | ≥3 years |
| Oxygen Measurement | Integrated paramagnetic/O₂ sensor |
| Weight | ~13 kg |
| Carrier Gas | Not required |
| Combustion Air | Built-in compressor — no external air supply needed |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | AQ7100 |
| Pricing | Available upon Request |
| Measured Parameters | SO₂, NO₂, CO, O₃, PM₂.₅, PM₁₀, TVOC, Temperature, Relative Humidity |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LD1200A |
| Pricing | Upon Request |
| Measurement Principle | Laser Forward Light Scattering |
| Safety Rating | Non-Explosive |
| Measurement Range | 0–15 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ±2% |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | AQ7800 |
| Instrument Type | Online Fixed-Station Analyzer |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Measurement Method | Direct Analysis (Non-Preconcentration Bypass Mode with Cold Trap Preconcentration Option) |
| Detection Limit | ≤1 ppbC (as Carbon) |
| Compliance | HJC-ZY84-2020 |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VM1700 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Target Analytes | Methane (CH₄), Total Hydrocarbons (THC), Non-Methane Hydrocarbons (NMHC), and selected BTEX compounds |
| Sample Path Temperature | 175 °C (fully heated from probe to detector) |
| Compliance | Certified by China National Environmental Monitoring Centre (CNEMC) for CEMS applicability testing |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS 1200 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ≤ ±5% FS |
| Repeatability | ≤ 1% FS |
| Response Time | ≤ 90 s |
| Drift Stability | ≤ 1% FS over 7 days |
| Measured Parameters | SO₂, NOₓ (NO + NO₂), O₂, CO, CO₂, HCl, particulate matter (PM) concentration, flue gas velocity, static pressure, relative humidity, emission rate, and cumulative emissions |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CEMS1250 |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Measurement Accuracy | ±2.5% FS |
| Repeatability | ±2% FS |
| Response Time | 200 s |
| Long-term Stability | ±5% FS |
| Measured Parameters | SO₂, NO, O₂, Particulate Matter (PM) Concentration, Flue Gas Temperature, Pressure, Velocity, Relative Humidity |
| Derived Outputs | Emission Rate, Total Emissions |
| Sampling Method | Direct Extraction with Cold-Dry Conditioning |
| Certified Low-Range Quantification | SO₂ & NO at 0–45 mg/m³ |
| PM Detection Principle | Laser Forward Scattering |
| PM Certified Range | 0–15 mg/m³ |
| Compliance | Meets Chinese HJ 75–2017 and HJ 76–2017 Technical Specifications for CEMS |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS1200 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measured Parameters | SO₂, NOₓ (NO, NO₂), O₂ |
| Measurement Principle (O₂) | Electrochemical Sensor |
| Measurement Principle (Temperature) | PT100 or Thermocouple Sensor |
| Measurement Principle (Pressure) | Piezoresistive Pressure Transducer |
| Measurement Principle (Flow Velocity) | Pitot Tube |
| Measurement Principle (Humidity) | High-Temperature Capacitive Hygrometer |
| Sampling Method | Direct Extraction – Hot/Wet Method |
| Certified SO₂ Range | 0–70 mg/m³ |
| Certified NO Range | 0–65 mg/m³ |
| Particulate Matter Method | Laser Forward Scattering |
| Certified PM Range | 0–15 mg/m³ |
| Data Interface | Modbus RTU/TCP, OPC UA, 4–20 mA, RS-232/485 |
| Compliance Support | GB/T 16157, HJ 75–2017, HJ 76–2017, ISO 12039, EN 15267 |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VM1750 |
| Instrument Principle | Cryogenic Preconcentration Coupled with Gas Chromatography–Mass Spectrometry (GC-MS) |
| Configuration | Online Continuous Monitoring System |
| Response Time | ≤5 s (T90) |
| Target Analytes | 116 VOCs including PAMS, TO-14/TO-15 compounds, and C1–C10 aldehydes & ketones |
| Detection Capability | Sub-ppt (pg/m³) level quantification |
| Detector Configuration | Dual-channel detection via Flame Ionization Detector (FID) and Quadrupole Mass Spectrometer (MS) |
| Sample Introduction | Automated, unattended, real-time ambient air sampling |
| Surface Treatment | Fully passivated gas pathways (SilcoNert® or equivalent inert coating) |
| Compliance Readiness | Designed to support EPA Method TO-14A, TO-15, ASTM D5504, and ISO 16017-1 workflows |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | AQ7000 |
| Quotation | Upon Request |
| Monitored Pollutants | SO₂, NO, NOₓ, CO, O₃, PM₂.₅, PM₁₀ |
| Meteorological Parameters | Wind Speed, Wind Direction, Temperature, Relative Humidity, Atmospheric Pressure |
| Optional Add-ons | Rainfall, Noise Level, Solar Radiation |
| Data Acquisition | Integrated Substation Data Logger with Standardized Digital Interfaces |
| Calibration System | Dynamic Calibrator and Zero Air Generator |
| Compliance Framework | Designed for alignment with HJ 653–2013, HJ 654–2013, ISO 20815, EPA Reference Methods (e.g., EQOA-0017 for PM₂.₅), and GLP/GMP-aligned data integrity practices |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TOF2000 |
| Instrument Principle | Single-Photon Ionization Time-of-Flight Mass Spectrometry (SPI-TOF-MS) |
| Configuration | Online Fixed/Mobile Deployment |
| Response Time | Sub-second (≤1 s) |
| Analyte Capacity | >300 Atmospheric Volatile Organic Compounds (VOCs) |
| Mass Resolution | >2000 FWHM (Toluene) |
| Linear Dynamic Range | 4 orders of magnitude |
| Vacuum System | Turbo-molecular pump cascade (3-stage) + backing mechanical pump |
| Ionization Source | 10.8 eV VUV lamp (soft ionization) |
| Mass Analyzer | Orthogonal acceleration reflectron TOF with second-order spatial and energy focusing |
| Detection Mode | Direct ambient sampling, no pre-concentration or chromatographic separation required |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS1300 |
| Instrument Type | Continuous Emissions Monitoring System (CEMS) |
| Measured Gases | CO₂, SO₂, NO, NO₂ |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Compliance | Certified by China National Environmental Monitoring Centre (CNEMC) for Applicability Testing |
| Data Output | Wet-base, dry-base, and normalized (e.g., 6% O₂) concentration values |
| Calibration | Automated zero/span calibration with diagnostic and alarm functions |
| Connectivity | LAN-based distributed architecture with remote data access capability |
| Regulatory Alignment | Designed to support compliance with China’s HJ 75–2017 and HJ 76–2017 standards |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SG1500 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% FS |
| Repeatability | ≤2% FS |
| Response Time | ≤90 s |
| Baseline Stability | ±2% FS over 24 h |
| Measured Gases | SO₂, NO, O₂, NOₓ, NH₃ |
| Optional Extension | CO₂ |
| Operating Temperature Range (Sampling Path) | Up to 180 °C |
| Display | 7″ Color TFT Touchscreen |
| Data Output | USB Export (1-min & 5-min Averaged Reports), Optional Thermal Printer Support |
| Compliance Features | Built-in Humidity Sensor (wet-to-dry basis conversion), Automatic Leak Check, Flow & Pressure Compensation, Dual-Range Selection for SO₂/NOₓ, Real-time Trend Plotting, GLP-Compliant Audit Trail Logging |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | CEMS1900 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Accuracy | ≤ ±2% of Full Scale (F.S.) |
| Response Time | ≤ 200 s (typical gases) |
| Thermal Stability | Full-path high-temperature conditioning at 180 °C |
| Measured Gases | SO₂, NO, NO₂, NOₓ, NH₃, HCl, HF, O₂, CO, CO₂, CH₄, H₂O (wet/dry basis & normalized concentrations) |