BrandASD
OriginCanada
ModeliGCS
Dilution Ratio Range1:2 to 1:3500 (customizable up to 1:10,000)
Accuracy< 0.5% rel.
Pressure ControlHigh-precision electronic pressure controllers (EPC) with temperature compensation
Flow Path MaterialFully welded stainless steel
Operating TemperatureUp to 200 °C (heated path option)
ConfigurabilityUser-selectable sonic nozzles and diluent gases
Flow Path OptionsDual direct-coupled EPC configuration or high-integrity bypass EPC version
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelN2 Sense
Detection Limit0.5 ppb
Repeatability<1%
Detector TypeEnhanced Plasma Discharge (EPD)
Column Temperature RangeAmbient +4 °C to 450 °C
Carrier Gas RequirementHigh-Purity Gas
Output4–20 mA, Ethernet, RS-232, MQTT
Data Storage12-month onboard logging
Dimensions133 × 202 × 330 mm (19″ rack-mountable)
Power24 VDC, 40 W
Operating Temperature5–40 °C
Sample Flow Rate5–200 mL/min
Inlet Pressure3–25 PSIG
Response Time<10 s (90% step change at 75 mL/min)
Drift<0.5% FS
Measurement Ranges0–1 ppm, 0–10 ppm, 0–100 ppm, up to 1% N₂ in Ar/He
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKA5800
Instrument TypeOnline Analyzer
Application ScopeGeneral-Purpose
Operating SystemEmbedded Linux with Touchscreen Interface
Detection PrincipleDual-Polarity Pulsed Electrochemical Conductivity Detection
Data AcquisitionReal-Time Asynchronous Parallel Chromatography
Sample IntroductionAutomated Multi-Channel Switching with Integrated Pre-Treatment Module
Calibration MethodSingle-Point Standard-Based Auto-Calibration
Detection EnhancementeLOD Noise-Filtering Algorithm (3–5× Sensitivity Gain)
Gas Capture TechnologyMulti-Threaded Aeration Trapping (KA5800-EIC Variant, Patent Pending)
Analysis Cycle<30 min per Full Sequence
Sample Volume Requirement≤1.5 L for ppb-Level Analysis
Compliance FrameworkDesigned for GLP/GMP Environments
Temperature ControlDigital Precision Dual-Zone Column & Detector Thermostat
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKA8000plus-S
Instrument TypeLaboratory Gas Chromatograph
Application FieldHydrogen Fuel Purity Analysis
Temperature Control RangeAmbient +4 °C to 450 °C
Maximum Ramp Rate75 °C/min
Cooling Rate~6 min (400 °C → 50 °C)
Carrier Gas Flow Range & Control30–100 mL/min
Carrier Gas Pressure Range & Control90–100 psig
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range3–25 psig
Injector Total Flow Setting Range5–200 mL/min
DetectorSePDD (Sulfur-Enhanced Plasma Discharge Detector)
Valve ConfigurationPLSV Inert 6-Port Valve with 2 mL Inert Quantitative Loop
Carrier Gas RequirementUltra-High-Purity Helium (≥5.0, purified to <1 ppb total impurities via ASDPure gas purifier)
Detection Limit<0.5 ppb (as H₂S equivalent, direct injection)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKA
OriginCanada
ModelKA6000
Repeatability<1%
Detection Limit1 ppb
Detector TypeEnhanced Plasma Discharge Detector (EPD)
Column Oven Temperature Range−5 °C to 300 °C
Carrier GasesN₂, Ar, He
ComplianceFully compatible with ASTM D7622, ISO 8573-5, USP <467>, and EPA Method TO-15/TO-17 workflows
SoftwareEmbedded GC control platform with 21 CFR Part 11–compliant audit trail and GLP/GMP data integrity architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKA
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelKA8000Ex
Price RangeUSD 68,000–136,000 (FOB)
Repeatability<1% RSD
Detection Limit<1 ppb (H₂S, COS, SO₂, CH₃SH)
Detector TypeEnhanced Plasma Detector (EPD)
Column Oven Temperature Range−5°C to 300°C
Carrier Gas RequirementsArgon, Helium, or Nitrogen (inert only)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKA8000
Instrument TypeOnline Gas Chromatograph
Temperature Control RangeAmbient + 4 °C to 450 °C
Ramp Rate30–60 °C/min
Cool-down Rate30–60 °C/min
Carrier Gas Flow Range & Control20–50 mL/min
Carrier Gas Pressure Range & Control90–100 psig
Injector Maximum Operating Temperature200 °C
Injector Pressure Setting Range5–15 psig
Injector Total Flow Setting Range20–30 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelASDPureTM
Detection TargetsTrace impurities in helium, hydrogen, nitrogen, carbon dioxide, and other industrial gases
Compatible GasesAr, He, Ne, Xe, Kr (N₂ purification optional)
Impurities RemovedH₂O, O₂, CO, CO₂, H₂, THC, CH₄, N₂
Purification Depth<1 ppb
Flow Rate Options300 mL/min, 1 L/min, 5 L/min
Operating TemperatureAmbient
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKA0211
Repeatability±1% FS
Detection Limit0.03 ppm
Detector TypeTCD (Thermal Conductivity Detector)
Column Oven Temperature Range5 °C to 45 °C
Carrier Gas Purity Requirement5N (99.999%)
ComplianceDesigned for continuous online operation in industrial process environments
ConfigurationModular sensor architecture with field-replaceable sensing modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelFEPID
Compatible InstrumentGas Chromatograph (GC)
Detector TypePhotoionization Detector (PID)
Wavelength Range100–900 nm
Detection PrincipleEmission-based Photoionization
UV SourceDielectric Barrier Discharge (DBD) Ultraviolet Lamp
Noise Level<1% RMS
Detection Limit1 ppb (for benzene-equivalent VOCs)
Baseline Drift<1% over 24 h
Signal Channels4 independent analog/digital outputs
Calibration Accuracy & Repeatability±0.1% of full scale
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
Manufacturer TypeGeneral Distributor
Origin CategoryImported
ModelSePdd
QuotationUpon Request
Compatible InstrumentGas Chromatograph
Instrument TypeSpecialized Chromatographic Detector
Wavelength Range100 nm – 900 nm
Detection ModeEmission
Light SourcePlasma Discharge
Noise<1%
Detection Limit1 ppb
Baseline Drift<1%
Signal Channels4
Adjustment Accuracy / Repeatability±1%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelASDPure-POU
Purification TargetsH₂O, O₂, H₂, CO, CO₂ to < 0.1 ppbv
Final Purity Level< 1 ppb
Maximum Flow Rate< 2000 SLPM
Operating TemperatureAmbient
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelCGA
PriceUSD 28,000 (approx.)
Linearity Error<0.1% FS
Repeatability<0.1% FS
Span Drift≤1% per 30 days
Response Time (T90)5 seconds
Explosion ProtectionNot certified (non-hazardous area use only)
Sensor TechnologiesFID, NDIR, Paramagnetic, Electrochemical (eCell), Alumina-based Hygrometer (Al₂O₃), EPD (Electrostatic Precipitation Detector)
Temperature CompensationIntegrated
Pressure CompensationIntegrated
Calibration OptionsMulti-point auto-calibration available per module
Module ArchitectureUp to 3 internal sensor modules + 1 external Al₂O₃ module
Data LoggingOnboard with real-time trend visualization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelIC-KA5800
Instrument TypeOnline Analyzer
Application ScopeUniversal Gas Impurity Analysis
Compliance FrameworkASTM D7622, ISO 14687-2, GB/T 37244–2018, USP <645> (for total ionizable impurities)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKa6000 Plus
Instrument TypeOnline Gas Chromatograph
Temperature Control RangeAmbient +4 °C to 450 °C
Maximum Ramp Rate75 °C/min
Cooling Rate~6 min (from 400 °C to 50 °C)
Carrier Gas Flow Range30–100 mL/min
Carrier Gas Pressure Range90–100 psig
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range3–25 psig
Injector Total Flow Setting Range5–200 mL/min
Column Oven ZonesUp to 4 independently controlled zones
ValvesUp to 5 programmable PLSV valves
DetectorsUp to 2 gas-phase detectors (e.g., EPD)
Detection Limit (LOD)<1 ppb (stable, compound-dependent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelPAD
Instrument TypeLaboratory Gas Chromatograph
Application FieldCoal Industry-Specific
Temperature Control Range−4 °C to 450 °C
Oven Ramp Rate30–60 °C/min
Oven Cool-Down Rate30–60 °C/min
Carrier Gas Flow Range & Control20–50 mL/min
Carrier Gas Pressure Range & Control90–100 psig
Injector Maximum Operating Temperature200 °C
Injector Pressure Setting Range5–15 psig
Injector Total Flow Setting Range20–30 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASDevices
OriginCanada
ModelGC-EPD
Compatible InstrumentGas Chromatograph
Detector TypePlasma-Based Universal Detector
Wavelength Range100 nm – 900 nm
Detection ModeEmission
Excitation SourceRadio-Frequency Plasma
Noise Level0.1 mV (RMS, 1 Hz bandwidth)
Detection Limit0.5 ppb (for halogenated compounds)
Baseline Drift≤1% over 24 h
Signal Channels4 independent analog inputs
Calibration Accuracy & Reproducibility±1% (full-scale)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKA
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
Modelhytrace Integrated Analyzer
Instrument TypePortable Gas Chromatograph
Application ScopeGeneral-purpose, Hydrogen Purity Monitoring
Oven Temperature RangeAmbient +4 °C to 450 °C
Ramp RateUp to 75 °C/min
Cool-down Time~6 min (from 400 °C to 50 °C)
Carrier Gas Flow Control Range30–100 mL/min
Carrier Gas Pressure Control Range90–100 psig
Injector Maximum Temperature400 °C
Injector Pressure Setting Range3–25 psig
Injector Total Flow Setting Range5–200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASDevices
OriginCanada
ModelCYPPB-01
Instrument TypeOnline Gas Chromatograph
Application ScopeGeneral-Purpose
Dilution Ratio Range1:2 to 1:3500 (customizable up to 1:10,000)
Relative Accuracy< 0.5%
Certified TraceabilityNIST-traceable calibration certificate
Core TechnologyCritical-Orifice-Based Sonic Nozzle Dynamic Dilution
ConstructionAll-welded stainless steel flow path
Temperature-Controlled PathUp to 200 °C
Pressure RegulationDual EPC with temperature compensation
Flow Configuration OptionsDirect-coupled or high-integrity bypass
Purification ModuleiGCSASDPure integrated gas purifier
ComplianceDesigned for ISO/IEC 17025-compliant calibration labs and GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASDevices
OriginCanada
ModelKA8000Ex
Repeatability±2%
Detection Limit (MDL)0.5 ppb H₂S
Detector TypeEPD (Enhanced Plasma Discharge Detector)
Column Oven Temperature Range−4 °C to 200 °C
Carrier Gas Requirement5N-grade He, Ar, or N₂
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKA
OriginCanada
ModelKA 8000Plus
Repeatability<1% RSD
Detection Limit0.5 ppb
Detector TypeEnhanced Plasma Discharge Detector (EPD)
Column Oven Temperature Range–4 °C to 450 °C
Carrier Gas RequirementUltra-High-Purity Gases
Regulatory StatusImport-Class Industrial Instrument
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKA0221
Repeatability< ±0.1% O₂
Detection Limit< ±0.1% O₂
Detector TypeParamagnetic
Column Temperature Control Range5 °C to 45 °C
Gas Supply Purity5N (99.999%)
Output4–20 mA
CommunicationRS-485, Ethernet, Modbus (optional)
Relay Outputs3 × user-configurable dry-contact relays
Data ExportCSV format
CalibrationAuto/manual zero/span, multi-point, calendar-based scheduling, programmable purge time, intelligent stability detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModeliSCS
ConfigurationRack-mountable (19″) or Benchtop Standalone
Cooling Trap Temperature–30 °C
Thermal Desorption RangeUp to 300 °C
Valve TechnologyPLSV (Precision Low-Dead-Volume Sampling Valve)
Operation ModesProgrammable Stepwise Release or Flash Desorption
Diagnostic CapabilityIntegrated Self-Diagnostic System
ConnectivityIoT-enabled for ASDevices Ecosystem
Sample IntroductionFront-accessible Cold Trap and Valve Assembly
ComplianceDesigned for GLP/GMP-aligned laboratory workflows