| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | iGCS |
| Dilution Ratio Range | 1:2 to 1:3500 (customizable up to 1:10,000) |
| Accuracy | < 0.5% rel. |
| Pressure Control | High-precision electronic pressure controllers (EPC) with temperature compensation |
| Flow Path Material | Fully welded stainless steel |
| Operating Temperature | Up to 200 °C (heated path option) |
| Configurability | User-selectable sonic nozzles and diluent gases |
| Flow Path Options | Dual direct-coupled EPC configuration or high-integrity bypass EPC version |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | N2 Sense |
| Detection Limit | 0.5 ppb |
| Repeatability | <1% |
| Detector Type | Enhanced Plasma Discharge (EPD) |
| Column Temperature Range | Ambient +4 °C to 450 °C |
| Carrier Gas Requirement | High-Purity Gas |
| Output | 4–20 mA, Ethernet, RS-232, MQTT |
| Data Storage | 12-month onboard logging |
| Dimensions | 133 × 202 × 330 mm (19″ rack-mountable) |
| Power | 24 VDC, 40 W |
| Operating Temperature | 5–40 °C |
| Sample Flow Rate | 5–200 mL/min |
| Inlet Pressure | 3–25 PSIG |
| Response Time | <10 s (90% step change at 75 mL/min) |
| Drift | <0.5% FS |
| Measurement Ranges | 0–1 ppm, 0–10 ppm, 0–100 ppm, up to 1% N₂ in Ar/He |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA5800 |
| Instrument Type | Online Analyzer |
| Application Scope | General-Purpose |
| Operating System | Embedded Linux with Touchscreen Interface |
| Detection Principle | Dual-Polarity Pulsed Electrochemical Conductivity Detection |
| Data Acquisition | Real-Time Asynchronous Parallel Chromatography |
| Sample Introduction | Automated Multi-Channel Switching with Integrated Pre-Treatment Module |
| Calibration Method | Single-Point Standard-Based Auto-Calibration |
| Detection Enhancement | eLOD Noise-Filtering Algorithm (3–5× Sensitivity Gain) |
| Gas Capture Technology | Multi-Threaded Aeration Trapping (KA5800-EIC Variant, Patent Pending) |
| Analysis Cycle | <30 min per Full Sequence |
| Sample Volume Requirement | ≤1.5 L for ppb-Level Analysis |
| Compliance Framework | Designed for GLP/GMP Environments |
| Temperature Control | Digital Precision Dual-Zone Column & Detector Thermostat |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA8000plus-S |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Hydrogen Fuel Purity Analysis |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 30–100 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Detector | SePDD (Sulfur-Enhanced Plasma Discharge Detector) |
| Valve Configuration | PLSV Inert 6-Port Valve with 2 mL Inert Quantitative Loop |
| Carrier Gas Requirement | Ultra-High-Purity Helium (≥5.0, purified to <1 ppb total impurities via ASDPure gas purifier) |
| Detection Limit | <0.5 ppb (as H₂S equivalent, direct injection) |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA6000 |
| Repeatability | <1% |
| Detection Limit | 1 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | −5 °C to 300 °C |
| Carrier Gases | N₂, Ar, He |
| Compliance | Fully compatible with ASTM D7622, ISO 8573-5, USP <467>, and EPA Method TO-15/TO-17 workflows |
| Software | Embedded GC control platform with 21 CFR Part 11–compliant audit trail and GLP/GMP data integrity architecture |
| Brand | KA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KA8000Ex |
| Price Range | USD 68,000–136,000 (FOB) |
| Repeatability | <1% RSD |
| Detection Limit | <1 ppb (H₂S, COS, SO₂, CH₃SH) |
| Detector Type | Enhanced Plasma Detector (EPD) |
| Column Oven Temperature Range | −5°C to 300°C |
| Carrier Gas Requirements | Argon, Helium, or Nitrogen (inert only) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA8000 |
| Instrument Type | Online Gas Chromatograph |
| Temperature Control Range | Ambient + 4 °C to 450 °C |
| Ramp Rate | 30–60 °C/min |
| Cool-down Rate | 30–60 °C/min |
| Carrier Gas Flow Range & Control | 20–50 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Maximum Operating Temperature | 200 °C |
| Injector Pressure Setting Range | 5–15 psig |
| Injector Total Flow Setting Range | 20–30 mL/min |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | ASDPureTM |
| Detection Targets | Trace impurities in helium, hydrogen, nitrogen, carbon dioxide, and other industrial gases |
| Compatible Gases | Ar, He, Ne, Xe, Kr (N₂ purification optional) |
| Impurities Removed | H₂O, O₂, CO, CO₂, H₂, THC, CH₄, N₂ |
| Purification Depth | <1 ppb |
| Flow Rate Options | 300 mL/min, 1 L/min, 5 L/min |
| Operating Temperature | Ambient |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0211 |
| Repeatability | ±1% FS |
| Detection Limit | 0.03 ppm |
| Detector Type | TCD (Thermal Conductivity Detector) |
| Column Oven Temperature Range | 5 °C to 45 °C |
| Carrier Gas Purity Requirement | 5N (99.999%) |
| Compliance | Designed for continuous online operation in industrial process environments |
| Configuration | Modular sensor architecture with field-replaceable sensing modules |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FEPID |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Photoionization Detector (PID) |
| Wavelength Range | 100–900 nm |
| Detection Principle | Emission-based Photoionization |
| UV Source | Dielectric Barrier Discharge (DBD) Ultraviolet Lamp |
| Noise Level | <1% RMS |
| Detection Limit | 1 ppb (for benzene-equivalent VOCs) |
| Baseline Drift | <1% over 24 h |
| Signal Channels | 4 independent analog/digital outputs |
| Calibration Accuracy & Repeatability | ±0.1% of full scale |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | SePdd |
| Quotation | Upon Request |
| Compatible Instrument | Gas Chromatograph |
| Instrument Type | Specialized Chromatographic Detector |
| Wavelength Range | 100 nm – 900 nm |
| Detection Mode | Emission |
| Light Source | Plasma Discharge |
| Noise | <1% |
| Detection Limit | 1 ppb |
| Baseline Drift | <1% |
| Signal Channels | 4 |
| Adjustment Accuracy / Repeatability | ±1% |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | ASDPure-POU |
| Purification Targets | H₂O, O₂, H₂, CO, CO₂ to < 0.1 ppbv |
| Final Purity Level | < 1 ppb |
| Maximum Flow Rate | < 2000 SLPM |
| Operating Temperature | Ambient |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | CGA |
| Price | USD 28,000 (approx.) |
| Linearity Error | <0.1% FS |
| Repeatability | <0.1% FS |
| Span Drift | ≤1% per 30 days |
| Response Time (T90) | 5 seconds |
| Explosion Protection | Not certified (non-hazardous area use only) |
| Sensor Technologies | FID, NDIR, Paramagnetic, Electrochemical (eCell), Alumina-based Hygrometer (Al₂O₃), EPD (Electrostatic Precipitation Detector) |
| Temperature Compensation | Integrated |
| Pressure Compensation | Integrated |
| Calibration Options | Multi-point auto-calibration available per module |
| Module Architecture | Up to 3 internal sensor modules + 1 external Al₂O₃ module |
| Data Logging | Onboard with real-time trend visualization |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | IC-KA5800 |
| Instrument Type | Online Analyzer |
| Application Scope | Universal Gas Impurity Analysis |
| Compliance Framework | ASTM D7622, ISO 14687-2, GB/T 37244–2018, USP <645> (for total ionizable impurities) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | Ka6000 Plus |
| Instrument Type | Online Gas Chromatograph |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range | 30–100 mL/min |
| Carrier Gas Pressure Range | 90–100 psig |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Column Oven Zones | Up to 4 independently controlled zones |
| Valves | Up to 5 programmable PLSV valves |
| Detectors | Up to 2 gas-phase detectors (e.g., EPD) |
| Detection Limit (LOD) | <1 ppb (stable, compound-dependent) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | PAD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Coal Industry-Specific |
| Temperature Control Range | −4 °C to 450 °C |
| Oven Ramp Rate | 30–60 °C/min |
| Oven Cool-Down Rate | 30–60 °C/min |
| Carrier Gas Flow Range & Control | 20–50 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Maximum Operating Temperature | 200 °C |
| Injector Pressure Setting Range | 5–15 psig |
| Injector Total Flow Setting Range | 20–30 mL/min |
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | GC-EPD |
| Compatible Instrument | Gas Chromatograph |
| Detector Type | Plasma-Based Universal Detector |
| Wavelength Range | 100 nm – 900 nm |
| Detection Mode | Emission |
| Excitation Source | Radio-Frequency Plasma |
| Noise Level | 0.1 mV (RMS, 1 Hz bandwidth) |
| Detection Limit | 0.5 ppb (for halogenated compounds) |
| Baseline Drift | ≤1% over 24 h |
| Signal Channels | 4 independent analog inputs |
| Calibration Accuracy & Reproducibility | ±1% (full-scale) |
| Brand | KA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | hytrace Integrated Analyzer |
| Instrument Type | Portable Gas Chromatograph |
| Application Scope | General-purpose, Hydrogen Purity Monitoring |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Ramp Rate | Up to 75 °C/min |
| Cool-down Time | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Control Range | 30–100 mL/min |
| Carrier Gas Pressure Control Range | 90–100 psig |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | CYPPB-01 |
| Instrument Type | Online Gas Chromatograph |
| Application Scope | General-Purpose |
| Dilution Ratio Range | 1:2 to 1:3500 (customizable up to 1:10,000) |
| Relative Accuracy | < 0.5% |
| Certified Traceability | NIST-traceable calibration certificate |
| Core Technology | Critical-Orifice-Based Sonic Nozzle Dynamic Dilution |
| Construction | All-welded stainless steel flow path |
| Temperature-Controlled Path | Up to 200 °C |
| Pressure Regulation | Dual EPC with temperature compensation |
| Flow Configuration Options | Direct-coupled or high-integrity bypass |
| Purification Module | iGCSASDPure integrated gas purifier |
| Compliance | Designed for ISO/IEC 17025-compliant calibration labs and GLP/GMP environments |
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | KA8000Ex |
| Repeatability | ±2% |
| Detection Limit (MDL) | 0.5 ppb H₂S |
| Detector Type | EPD (Enhanced Plasma Discharge Detector) |
| Column Oven Temperature Range | −4 °C to 200 °C |
| Carrier Gas Requirement | 5N-grade He, Ar, or N₂ |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA 8000Plus |
| Repeatability | <1% RSD |
| Detection Limit | 0.5 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | –4 °C to 450 °C |
| Carrier Gas Requirement | Ultra-High-Purity Gases |
| Regulatory Status | Import-Class Industrial Instrument |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0221 |
| Repeatability | < ±0.1% O₂ |
| Detection Limit | < ±0.1% O₂ |
| Detector Type | Paramagnetic |
| Column Temperature Control Range | 5 °C to 45 °C |
| Gas Supply Purity | 5N (99.999%) |
| Output | 4–20 mA |
| Communication | RS-485, Ethernet, Modbus (optional) |
| Relay Outputs | 3 × user-configurable dry-contact relays |
| Data Export | CSV format |
| Calibration | Auto/manual zero/span, multi-point, calendar-based scheduling, programmable purge time, intelligent stability detection |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | iSCS |
| Configuration | Rack-mountable (19″) or Benchtop Standalone |
| Cooling Trap Temperature | –30 °C |
| Thermal Desorption Range | Up to 300 °C |
| Valve Technology | PLSV (Precision Low-Dead-Volume Sampling Valve) |
| Operation Modes | Programmable Stepwise Release or Flash Desorption |
| Diagnostic Capability | Integrated Self-Diagnostic System |
| Connectivity | IoT-enabled for ASDevices Ecosystem |
| Sample Introduction | Front-accessible Cold Trap and Valve Assembly |
| Compliance | Designed for GLP/GMP-aligned laboratory workflows |