| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | EA05 |
| Pricing | Upon Request |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Model | Code 1005705 |
| Construction | Benchtop stainless steel test chamber with integrated fume extraction system |
| Flame Calibration | Compliant with ASTM D 5207 for 20 mm and 125 mm flame verification |
| Gas Supply | Methane feed panel with precision flowmeter, adjustable valve, and pressure gauge |
| Operator Interface | Dual hand-access ports with front-opening tempered glass viewing panels |
| Safety Integration | Built-in fume aspirator with foot-pedal activation |
| Compliance | Designed for UL 94 HB, V-0, V-1, V-2, 5VA, 5VB, VTM-1, and VTM-2 test protocols |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Code 10004050 |
| Pricing | Upon Request |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Authorization Status | Authorized Distributor |
| Import Status | Imported |
| Model No. | 10097101 |
| Power Supply | 400 V AC, 50 Hz, 3-phase, 32 A |
| Fuel Gas | Methane |
| Display | 17-inch integrated touchscreen |
| Standards Compliance | ISO 5660-1, ASTM E1354, BS EN ISO 5660-1, NFPA 271 |
| Key Measured Parameters | Heat Release Rate (HRR), Time to Ignition (TTI), Mass Loss Rate (MLR), Effective Heat of Combustion (EHC), Smoke Production Rate (SPR), CO/CO₂ Yield, Oxygen Consumption |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SC-610 |
| Pricing | Available Upon Request |
| Standards Compliance | NFPA 258-T, ASTM E662, BS 6401, ATS 1000.001 |
| Internal Chamber Dimensions | 914 × 610 × 614 mm (L × W × H) |
| Radiant Heat Source | 900 W adjustable furnace, max irradiance 2.5 W/cm² |
| Multi-flame Combustion Burner | Integrated gas mixing flowmeter, temperature-controlled |
| Optical Path | Collimated light beam (λ = 550 nm), photometric detection of transmitted intensity |
| Sample Holders | Three motorized, precision-positioned fixtures with automated insertion/retraction |
| Exhaust System | Servo-controlled pneumatic damper with differential pressure sensor |
| Control Interface | Touch-enabled digital panel with real-time parameter monitoring and preset profile storage |
| Data Acquisition | PC-based software with automated optical density (Ds) calculation per ASTM E662 §7.3, time-resolved smoke density curves (Ds vs. t), and integrated area under curve (AUC) reporting |