| Brand | ARA |
|---|---|
| Origin | USA |
| Model | N-FRM |
| Flow Rate | 10–20 LPM (nominal 16.7 LPM) |
| Flow Accuracy | ±2% (±1% with calibration) |
| Operating Time | >30 hours on rechargeable 18 V lithium battery |
| Charging Time | 1 hour |
| Data Output | USB flash drive interface |
| Dimensions | 25.4 × 30.48 × 17.78 cm |
| Sampling Weight | 15 lbs |
| Shipping Weight | 25 lbs |
| Filter Holder | Standard FRM-compliant 47 mm cassette mount |
| Particle Separation | Low-maintenance, oil-free cyclonic inlet for PM₂.₅ and PM₁₀ |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FTS |
| Pricing | Available Upon Request |
| Enclosure Dimensions | 10.62" × 9.68" × 4.87" (27 cm × 24.6 cm × 12.4 cm) |
| Weight | 5 lbs (2.27 kg) |
| Flow Ranges | 1–3 LPM, 2–9 LPM, 9–25 LPM |
| Flow Accuracy | ±1% of reading |
| Temperature Range | −30°C to +50°C |
| Temperature Accuracy | ±0.5°C |
| Barometric Pressure Range | 250–800 mmHg |
| Pressure Accuracy | ±5 mmHg |
| Battery | Rechargeable NiMH |
| Runtime | Up to 60 hours |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LFR-6 |
| Weight | 15 lb |
| Flow Rate Range | 3–10 L/min |
| Nominal Flow Rate | 6 L/min |
| Flow Accuracy | ±2% |
| Battery | 18 V Li-ion (rechargeable) |
| Charge Time | 1 h |
| Runtime | >30 h |
| Data Logging Interval | 5 min |
| Dimensions (L×W×H) | 10" × 12" × 7" |
| Shipping Weight | 25 lb |
| Filter Format | 47 mm FRM-compatible |
| Sampling Modes | TSP, PM₁₀, PM₂.₅ |
| Optional Sensors | Real-Time Particle (RTP) Sensor, PEET Anemometer, Optical Scattering Dust Monitor |
| Data Export | USB Flash Drive |
| Compliance | Designed to meet EPA Reference Method (FRM) criteria for low-flow particulate sampling |
| Brand | AII |
|---|---|
| Origin | USA |
| Model | GPR-1200 |
| Weight | 5.4 kg (12 lbs) |
| Measurement Range | 0–1 ppm to 0–100% O₂ |
| Accuracy | <2% of reading or 0.2 ppm (whichever is greater) |
| Response Time (T90) | <13 s |
| Detection Limit | 0.05 ppm |
| Sensor Lifetime | 24–32 months @ 25°C / 1 atm |
| Battery Life | Up to 30 days (standby), 40 hours (with internal pump active) |
| Operating Temperature | 5–45°C (GPR sensor) |
| Enclosure | Painted aluminum, NEMA 4X rated |
| Gas Inlet | 1/8" compression fitting |
| Pressure Range | 0.34–2 barg (5–30 psig) with vent |
| Output | 0–1 V analog |
| Compliance | ATEX Ex II 2 G Ex ib IIC T4 Gb, Tamb 5°C to +45°C |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 714 |
| NO₂ Range | 0–500 ppb |
| NO Range | 0–1000 ppb |
| O₃ Range | 0–500 ppb |
| Output Flow | 2.0–3.5 L/min (typ. 2.5–3.0 L/min) |
| Accuracy | ±2.0 ppb or ±2.0% of reading (whichever is greater) |
| Response Time to 95% of target concentration | <30 s |
| Power | 12 V DC / 120–240 V AC, 18 W (operational), 42 Wh (max during warm-up) |
| Dimensions (Rack-mount) | 43 cm × 37 cm × 14 cm (17″ × 14.5″ × 5.5″) |
| Weight | 7.0 kg (15.5 lb) |
| Programmable Sequences | Up to 99 stored methods, each with up to 15 steps (NO: up to 1000 ppb |
| NO₂/O₃ | up to 500 ppb) |
| Operating Temp | 0–40 °C |
| Storage Temp | −20–60 °C |
| RH | 0–80% non-condensing |
| Altitude | 0–2000 m |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Model 106M |
| Weight | 2.1 kg (4.7 lb) |
| Measurement Principle | UV Absorption at 254 nm |
| Range | 0–1000 ppmv |
| Resolution | 0.01 ppmv |
| Accuracy | ±0.01 ppmv or ±2% of reading |
| Detection Limit | 1.5 ppbv |
| Sampling Interval | 10 s (configurable averaging: 10 s, 1 min, 5 min, 1 hr) |
| Flow Rate | ~1 L/min |
| Data Storage | 12,288 points |
| Output Interfaces | USB, RS-232, 0–2.5 V analog, 4–20 mA |
| Analog Output Ranges | 0–1, 0–10, 0–100 ppmv (customizable) |
| Units Supported | ppb, ppm, pphm, µg/m³, mg/m³ |
| Humidity Management | Nafion® Dryer Tube (DewLine™) |
| Power | 12 V DC or 120/240 V AC, 350 mA, 4.2 W |
| Dimensions | 9.5 × 21.0 × 21.6 cm (3.75 × 8.25 × 8.50 in) |
| Alarm Indicators | LED status for power-on, [O₃] > 100 ppb, calibration due, filter replacement required |
| Brand | 2B Tech |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HERMES |
| Pricing | Upon Request |
Show next