BrandAnalox
OriginUnited Kingdom
ModelASPIDA
Instrument TypePortable
Detection TargetSingle-Gas (CO₂)
Measurement Range0.01–5.00% vol CO₂
Resolution0.01% vol
Accuracy±2% FS (0.01–2.5% range), ±3% FS (2.5–5.0% range)
Response Time (T90)<60 s
Zero Drift±1% FS/6 months
Span Drift±1% FS/6 months
Linearity Error±1% FS
Operating Temperature–5 to +50 °C
Battery2 × 2100 mAh NiMH AA
Runtime>12 h (continuous)
Charging Time4.5 h
DisplayHigh-visibility OLED
Alarm95 dB @ 30 cm (audible), tri-color LED indicators, fall detection alarm (110 dB)
Sensor TechnologyNon-dispersive infrared (NDIR), MIR-based
CO₂ Sensor Lifetime5 years
Optional O₂ SensorElectrochemical, 0.1–25.0% vol, T90 <30 s, 2-year lifetime
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalox
OriginUnited Kingdom
ModelSDA-CO2
Measurement PrincipleDual-Beam Non-Dispersive Infrared (NDIR)
Full-Scale Range0–5000 ppm / 0–2% CO₂
Accuracy±25 ppm or ±1% of reading (0–5000 ppm)
Repeatability±1% of full scale
Resolution1 ppm (0–5000 ppm range)
Zero Drift<±1% FS/month
Span Drift<±1% FS/month
Linearity Error±1% of full scale
DisplayHigh-brightness full-color TFT LCD
Output Options4–20 mA analog, relay outputs, Ethernet (Modbus TCP/IP configurable), optional data logging
ComplianceDNV GL OS-F101, IMCA D 018, Lloyds Register IR Class Rules, ABS Guide for Diving Systems, ADCI Consensus Standards
Sensor TypeAdvanced digital 5S3 NDIR sensor
MountingRack-mountable or panel-mountable
Enclosure RatingIP65 front panel
Operating Temperature0–45 °C
Power Supply100–240 VAC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANALOX
OriginUnited Kingdom
ModelHYP-MO2HBYY03
Instrument TypePortable
Measurement PrincipleElectrochemical (Clark-type pO₂ sensor)
Range0–2 bar ppO₂
Accuracy±1% of reading ±1 LSD
Temperature Effect±0.2% of reading / °C
Long-term Drift≤5% of reading per year
Zero Drift<1% FS/year
Span Drift<1% FS/year
Linearity Error±1% FS
Resolution0.01 bar ppO₂
Repeatability±1% FS
Operating Temperature0–40 °C
Operating Pressure0.8–60 bar absolute (≈600 msw / 2000 fsw)
Response Time (t₉₀)<15 s
Power Supply9 V PP3 battery
Battery Life800 h continuous operation
Dimensions64 × 98 × 36 mm
Weight0.200 kg
Sensor ModelAnalox 9100-9212-5H
Optional Probe9100-9212-2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalox
OriginUnited Kingdom
ModelAspida O2
Instrument TypePortable
Sensor Range0.1–25% O₂
Accuracy±0.0075% O₂
Visual Alarm Indicators1× green (normal), 1× amber (fault), 3× red (alarm)
Audible Alarm95 dB @ 30 cm
Emergency Alarm110 dB @ 30 cm
Response Time (T90)<30 s
Operating Temperature−5 to +50 °C
IP RatingIP65
Dimensions127 × 44 × 90 mm
Weight355 g
PowerDual-mode — rechargeable Li-ion battery or two standard AA alkaline cells
TWA CalculationYes
Vibration AlertYes
Multi-user SupportUp to 2 users with individual calibration & usage logs