- All
- Favorite
- Popular
- Most rated
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 211 |
| Instrument Type | Portable |
| Measurement Range | ppm |
| Limit of Detection | 1 ppb |
| Response Time | 2 s |
| Zero Drift | <0.5 %/day, <3 %/year |
| Resolution | 0.1 ppb |
| Operating Temperature | 10–50 °C |
| Power Supply | 11–14 V DC or 120/240 V AC, 8 W |
| Dimensions | 43 × 37 × 14 cm |
| Weight | 6.5 kg (14.3 lb) |
| Data Outputs | USB, RS-232, 0–2.5 V analog, optional 4–20 mA |
| Internal Memory | 16,333 records (scalable via USB flash drive) |
| Pressure & Temperature Compensation | Yes |
| DewLine™ Humidity Compensation | Yes |
| Flow Meter | Optional |
| Built-in Pump Lifetime | 20,000 hours |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106H |
| Instrument Type | Portable |
| Measurement Range | 1.5 ppbv to 100 ppmv |
| Detection Limit | 1 ppbv |
| Response Time | 10 s |
| Zero Drift | ±1 ppbv (24 h) |
| Resolution | 0.01 wt% (for 0–20 wt% range) |
| Operating Pressure | Up to 50 psi |
| Sampling Flow Rate | ~1 L/min |
| Data Storage Capacity | 12,288 points |
| Power Supply | 12 V DC or 120/240 V AC |
| Dimensions | 9.5 × 21.0 × 21.6 cm |
| Weight | 2.1 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | UV-106-W |
| Instrument Type | Portable |
| Measurement Range | 0–100 ppm (g/m³, µg/mL, mg/L) |
| Detection Limit | 0.1 ppm |
| Response Time | 20 s |
| Zero Drift | <0.05 ppm/month |
| Resolution | 0.1 ppm |
| Data Update Interval | 10 s |
| Accuracy | ±0.05 ppm or ±1% of reading |
| Sampling Flow Rate | 12 mL/min |
| Operating Pressure | 0–50 psi (burst pressure >100 psi) |
| Power | 11–14 VDC, 2.2 A @ 12 V (26.4 W) |
| Data Logger Capacity | 16,368 records |
| Dimensions | 33.8 × 30.5 × 18.5 cm |
| Weight | 6.6 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106W |
| Instrument Type | Portable |
| Measurement Range | 0–100 ppm |
| Detection Limit | 0.05 ppm (or ±1% of reading) |
| Response Time | <10 seconds (t₉₀) |
| Zero Drift | <0.02 ppm/24 h |
| Resolution | 0.01 ppm |
| Flow Rate | ~12 mL/min |
| Data Storage | 16,368 records |
| Sampling Interval Options | 10 s, 1 min, 5 min, 1 h |
| Output Interfaces | RS-232 serial, 0–2.5 V analog, LCD display, LED alarm |
| Power Supply | 12 V DC or 100–240 V AC, 5.0 W (3.9 W in low-power mode) |
| Dimensions | 33.8 × 30.5 × 18.5 cm |
| Weight | 6.6 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 205 |
| Instrument Type | Portable |
| Measurement Range | 0–250 ppm |
| Limit of Detection | 1 ppb |
| Response Time | 2 s |
| Zero Drift | ±1.5 ppb (24 h) |
| Resolution | 1.5 ppb |
| Power Requirement | 12 V DC, 5.0 W |
| Flow Rate | 1.8 L/min (min. 1.2 L/min) |
| Data Storage | 14,336 records |
| Weight | 2.1 kg (4.7 lb) |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106L |
| Instrument Type | Portable |
| Measurement Range | 1.5 ppbv – 100 ppmv |
| Limit of Detection | 1.5 ppbv |
| Response Time | 10 s |
| Zero Drift | ±1 ppbv (24 h) |
| Resolution | 1.5 ppbv |
| Accuracy | ±1.5 ppbv or ±2% of reading |
| Sampling Flow Rate | ~1 L/min |
| Data Storage Capacity | 12,288 points |
| Power Supply | 12 V DC or 100–240 V AC, 4.2 W |
| Dimensions | 9.5 × 21.0 × 21.6 cm |
| Weight | 2.1 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106-M |
| Instrument Type | Portable |
| Measurement Range | 0–1000 ppm |
| Limit of Detection | 0.01 ppm |
| Response Time | 10 s |
| Zero Drift | ±1 ppbv (24 h) |
| Resolution | 1.5 ppbv |
| Power Consumption | 3.6 W |
| Dimensions | 9.5 × 21.0 × 21.6 cm |
| Weight | 2.1 kg |
| Measurement Principle | UV Absorption at 254 nm |
| Data Storage Capacity | 12,288 points |
| Output Interfaces | USB, RS-232, 0–2.5 V analog, 4–20 mA analog |
| Sampling Flow Rate | ~1 L/min |
| Compliance | NIST-traceable calibration, compatible with EPA ambient air monitoring protocols |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106MH |
| Instrument Type | Fixed-Mount Ozone Analyzer |
| Measurement Range | 0–10,000 ppm (0–1 vol%) |
| Response Time | 2 s |
| Measurement Interval | 2 s |
| Optical Principle | UV Absorption at 254 nm |
| Flow Rate | 1 L/min |
| Data Storage Capacity | 32,736 rows (e.g., 113 days at 5-min averaging) |
| Output Interfaces | USB, RS-232, 0–2.5 V analog, 4–20 mA |
| Display | Integrated LCD |
| Power | 11–28 VDC, 500 mA, 6 W |
| Dimensions | 9 × 20 × 24 cm (3.65 × 7.9 × 9.4 in) |
| Weight | 1.9 kg (4.2 lb) |
| Compliance | Designed for EPA-compliant ambient and industrial ozone monitoring per Method TO-11A principles |
| Enclosure Options | Standard or NEMA-rated housing available |
| Brand | 2B Tech |
|---|---|
| Origin | USA |
| Model | POM |
| Instrument Type | Portable |
| Measurement Range | 0–10 ppm |
| Limit of Detection | 4 ppb |
| Response Time | 10 s |
| Zero Drift | 1.5 ppb |
| Resolution | 1 ppb |
| Detection Principle | UV Absorption at 254 nm |
| EPA Federal Equivalent Method (FEM) | EQOA-0815-227 |
| NIST-Traceable Calibration | Yes |
| Operating Temperature | 0–50 °C |
| Pressure Range | 150–1013 mbar (≈0–13.5 km altitude) |
| Power | 7.4 V Li-ion battery (5–8 h), or 100–240 VAC adapter |
| Dimensions (with GPS) | 12.7 × 7.6 × 3.8 cm |
| Weight (with battery) | 450 g |
Show next