Empowering Scientific Discovery

Beijing East & West Analytical Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic
ModelLIMS Wizard
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analysis
OriginBeijing, China
Manufacturer TypeManufacturer
Instrument TypeTime-of-Flight Mass Spectrometer
Chromatography ConfigurationComprehensive Two-Dimensional Gas Chromatography (GC×GC)
ModelGCxGC TOF MS 3300
Mass RangeNot specified
ResolutionNot specified
SensitivityNot specified
Scan Speed500 spectra/sec (≥15 kHz pusher frequency)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelCA-9000A
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBC
OriginAustralia
Modelenduro Z-1000
Instrument TypeGraphite Furnace AAS
Optical SystemDual-beam
MonochromatorPlane Grating
DetectorPhotomultiplier Tube (PMT)
Background CorrectionZeeman Effect
Adjustable Magnetic Field Strength0.6–1.0 T (0.1 T increments)
Lamp Holder8-position Auto-aligning
Wavelength SelectionAutomatic
Slit Width0.1–2.0 nm (0.1 nm increments)
Hollow Cathode & Electrodeless Discharge Lamp RecognitionEncoded
Ultra-Lamp Power Supply10 V (1 standard, up to 4 optional)
Resolution<0.2 nm
Sensitivity≤0.003 absorbance units for Cu at 324.8 nm
Detection Limit≤0.5 pg for Cd in graphite furnace mode
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analysis
OriginBeijing, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelGC-4085B
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBC
OriginAustralia
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelQuantima / Integra
Instrument TypeSequential Scanning ICP-OES
Detection Limit (Cu)0.7 ppb
Precision (RSD)≤0.5%
Long-Term Stability (RSD)≤1.0%
Wavelength Range160–800 nm
Optical Resolution0.006 nm (160–200 nm)
RF Generator Frequency40.68 MHz
Argon Consumption (aqueous samples)<11 L/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBC
OriginAustralia
ModelHG3000PII
TypeContinuous-Flow Hydride Generation System
Sample ThroughputUp to 60 samples/h
Detection CapabilitySub-ppt for As, Bi, Sn, Sb, Te, Se, and Hg
ConstructionPrecision Borosilicate Glass Reaction Manifold
Flow ArchitectureSegmented Gas-Liquid Flow with Integrated Phase Separation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBC
OriginAustralia
ModelCintra1010
Optical DesignDual-Beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Spectral Bandwidth2.0 nm (fixed)
Wavelength Accuracy±0.5 nm
Stray Light<0.01% T at 220 nm and 340 nm
AutomationMotorized Wavelength Scanning & Auto-Zero
ComplianceASTM E275, ISO 6223, USP <857>, FDA 21 CFR Part 11 (with optional audit trail module)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analytical
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelPTR-QMS3500
PricingUpon Request
Mass Range1.5–600 amu
ResolutionUnit Mass Resolution
Response Time100 ms
Detection Limit100 pptv (for benzene)
Linear Dynamic Range50 pptv – 10 ppmv
Adjustable Inlet Flow Rate80–800 sccm
Heated Capillary Inlet Length1.0 m (inert, temperature-controlled up to 150 °C)
Drift Tube/Reaction Chamber Temperature Range40–150 °C
Primary Reagent IonH₃O⁺
Optional Reagent IonsNH₄⁺, O₂⁺, NO⁺
Power Supply220 V AC
Dimensions (W × H × D)48 × 54.5 × 63 cm
Weight~100 kg
Remote Interface4–20 mA output & MODBUS RTU protocol support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analysis
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelICP-7760HP
Instrument TypeFull-Spectrum Direct-Reading ICP-OES
Price RangeUSD 70,000–100,000 (FOB Beijing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analytical
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (PRC)
ModelGC-4175
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analysis
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelEL-100
Instrument TypeEvaporative Light Scattering Detector (ELSD)
Wavelength450 nm (blue LED)
Detection MethodPhotomultiplier Tube (PMT)
Light SourceHigh-Stability Blue LED
Evaporation Zone Temperature RangeAmbient to 100 °C
Temperature Control Accuracy±1 °C
Solvent Flow Rate Compatibility10 µL/min – 3 mL/min
Nebulizing Gas Flow Rate300 mL/min – 1.5 L/min
Nebulizing Gas Pressure0.2–0.5 MPa
Detection Limit<1 ng (glucose, direct injection)
Baseline Noise<0.1 mV (at 1 mL/min mobile phase flow)
Dimensions (W×D×H)165 × 470 × 580 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analysis
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelICP-7762
PriceUpon Request
Wavelength Range165–800 nm
Observation ModeVertical Torch Dual-View Configuration
DetectorCCD with Auto-Adaptive Purge
Purge Gas SystemIndependent Dual-Path Purging (CCD + Optics Chamber)
Purge Gas OptionsArgon or Nitrogen (Selectable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analytical Instruments
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelAS-600
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandEastern Analytical
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGC-4095(A)
PricingUpon Request]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analytical
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeMatrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometer
ModelEbio Reader 3700 Plus
Regulatory StatusClass II Medical Device (Registration No.: Tianjin NMPA Approval No. 20222220402)
Intended UseClinical Microbiology Identification, Biomarker Profiling, SNP Genotyping, Viral Peptide Detection, Foodborne Pathogen Screening
ComplianceMeets GB/T 19001–2016 (ISO 9001:2015), YY/T 0287–2017 (ISO 13485:2016), and relevant Chinese NMPA medical device technical requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBC
OriginAustralia
ModelArgon Humidifier
ApplicationIn-line humidification of argon carrier gas for ICP-OES/ICP-MS sample introduction systems
ComplianceDesigned for integration with ISO/IEC 17025-compliant analytical workflows
Regulatory ContextSupports GLP/GMP-aligned sample introduction stability in high-salinity matrix analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBC
OriginAustralia
ModelXplorAA
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemDouble-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp
Resolution<0.2 nm
Sensitivity>0.8 A for 5 mg/L Cu solution
Precision (RSD)<0.45%
Detection LimitSub-ppb for most elements with graphite furnace
Software ControlHandheld PC-based interface
Lamp Positions2 fixed hollow cathode lamp slots
Upgrade PathField-upgradable to graphite furnace and hydride generation systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analysis
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame AAS
Model7030A
MonochromatorConcave Grating
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp
Spectral Bandwidth0.2 nm (measured spectral line half-width ≤ 0.2 nm ± 0.02 nm)
SensitivityCu, 2.0 mg/L → Abs ≥ 0.200 Abs
Repeatability (RSD)≤1%
Detection LimitCu ≤ 0.010 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBC
OriginAustralia
ModelSystem5000
Detection LimitSub-ppb for ~50 elements
Temperature RangeUp to 3000 °C
Sample Volume1–100 µL (1 µL increment)
Autosampler Capacity40 samples + 10 standards
Vial Sizes2 mL (samples/standards), 5 mL (auto-dilution), 10 mL (reagents/blanks)
Graphite TubePlatform-equipped high-performance tube
Gas ControlProgrammable purge gas selection (Ar, N₂, or mixed)
Chemical Modifier InjectionDual-channel, software-triggered
Syringe MaterialFully PTFE capillary
Wash Reservoir1 L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBC
OriginAustralia
ModelCintra4040
Optical DesignTrue Dual-Beam
Detector TypePhotodiode Array (PDA)
Wavelength AutomationFully Automatic
Slit Width Range0.1–2.0 nm
Stray Light<0.0005% T at 220 nm
Photometric Linearity±1.2% up to 5 Abs
Monochromator ConfigurationDual Littrow, Czerny-Turner
Dynamic Range>6 Abs (measured)
ComplianceASTM E275, ISO 6358, USP <857>, EP 2.2.25, JP 2.03
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelAS-500
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelCA-9000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analytical
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelGC-MS3110
Instrument TypeSingle Quadrupole Mass Spectrometer
GC/MS ConfigurationConventional Benchtop GC-MS
Mass Range1.5–800 Da
Resolution2 M (10% valley definition)
Sensitivity30:1 (S/N for 1 pg octafluoronaphthalene, m/z 272, in full-scan mode)
Scan Speed6000 u/sec
Show next