| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Time-of-Flight Mass Spectrometer |
| Chromatography Configuration | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) |
| Model | GCxGC TOF MS 3300 |
| Mass Range | Not specified |
| Resolution | Not specified |
| Sensitivity | Not specified |
| Scan Speed | 500 spectra/sec (≥15 kHz pusher frequency) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | enduro Z-1000 |
| Instrument Type | Graphite Furnace AAS |
| Optical System | Dual-beam |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Adjustable Magnetic Field Strength | 0.6–1.0 T (0.1 T increments) |
| Lamp Holder | 8-position Auto-aligning |
| Wavelength Selection | Automatic |
| Slit Width | 0.1–2.0 nm (0.1 nm increments) |
| Hollow Cathode & Electrodeless Discharge Lamp Recognition | Encoded |
| Ultra-Lamp Power Supply | 10 V (1 standard, up to 4 optional) |
| Resolution | <0.2 nm |
| Sensitivity | ≤0.003 absorbance units for Cu at 324.8 nm |
| Detection Limit | ≤0.5 pg for Cd in graphite furnace mode |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantima / Integra |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit (Cu) | 0.7 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (RSD) | ≤1.0% |
| Wavelength Range | 160–800 nm |
| Optical Resolution | 0.006 nm (160–200 nm) |
| RF Generator Frequency | 40.68 MHz |
| Argon Consumption (aqueous samples) | <11 L/min |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | HG3000PII |
| Type | Continuous-Flow Hydride Generation System |
| Sample Throughput | Up to 60 samples/h |
| Detection Capability | Sub-ppt for As, Bi, Sn, Sb, Te, Se, and Hg |
| Construction | Precision Borosilicate Glass Reaction Manifold |
| Flow Architecture | Segmented Gas-Liquid Flow with Integrated Phase Separation |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra1010 |
| Optical Design | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2.0 nm (fixed) |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.01% T at 220 nm and 340 nm |
| Automation | Motorized Wavelength Scanning & Auto-Zero |
| Compliance | ASTM E275, ISO 6223, USP <857>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PTR-QMS3500 |
| Pricing | Upon Request |
| Mass Range | 1.5–600 amu |
| Resolution | Unit Mass Resolution |
| Response Time | 100 ms |
| Detection Limit | 100 pptv (for benzene) |
| Linear Dynamic Range | 50 pptv – 10 ppmv |
| Adjustable Inlet Flow Rate | 80–800 sccm |
| Heated Capillary Inlet Length | 1.0 m (inert, temperature-controlled up to 150 °C) |
| Drift Tube/Reaction Chamber Temperature Range | 40–150 °C |
| Primary Reagent Ion | H₃O⁺ |
| Optional Reagent Ions | NH₄⁺, O₂⁺, NO⁺ |
| Power Supply | 220 V AC |
| Dimensions (W × H × D) | 48 × 54.5 × 63 cm |
| Weight | ~100 kg |
| Remote Interface | 4–20 mA output & MODBUS RTU protocol support |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ICP-7760HP |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Price Range | USD 70,000–100,000 (FOB Beijing) |
| Brand | Dongxi Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | EL-100 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 450 nm (blue LED) |
| Detection Method | Photomultiplier Tube (PMT) |
| Light Source | High-Stability Blue LED |
| Evaporation Zone Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Solvent Flow Rate Compatibility | 10 µL/min – 3 mL/min |
| Nebulizing Gas Flow Rate | 300 mL/min – 1.5 L/min |
| Nebulizing Gas Pressure | 0.2–0.5 MPa |
| Detection Limit | <1 ng (glucose, direct injection) |
| Baseline Noise | <0.1 mV (at 1 mL/min mobile phase flow) |
| Dimensions (W×D×H) | 165 × 470 × 580 mm |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ICP-7762 |
| Price | Upon Request |
| Wavelength Range | 165–800 nm |
| Observation Mode | Vertical Torch Dual-View Configuration |
| Detector | CCD with Auto-Adaptive Purge |
| Purge Gas System | Independent Dual-Path Purging (CCD + Optics Chamber) |
| Purge Gas Options | Argon or Nitrogen (Selectable) |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AS-600 |
| Pricing | Upon Request |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Matrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometer |
| Model | Ebio Reader 3700 Plus |
| Regulatory Status | Class II Medical Device (Registration No.: Tianjin NMPA Approval No. 20222220402) |
| Intended Use | Clinical Microbiology Identification, Biomarker Profiling, SNP Genotyping, Viral Peptide Detection, Foodborne Pathogen Screening |
| Compliance | Meets GB/T 19001–2016 (ISO 9001:2015), YY/T 0287–2017 (ISO 13485:2016), and relevant Chinese NMPA medical device technical requirements |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Argon Humidifier |
| Application | In-line humidification of argon carrier gas for ICP-OES/ICP-MS sample introduction systems |
| Compliance | Designed for integration with ISO/IEC 17025-compliant analytical workflows |
| Regulatory Context | Supports GLP/GMP-aligned sample introduction stability in high-salinity matrix analysis |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | XplorAA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | <0.2 nm |
| Sensitivity | >0.8 A for 5 mg/L Cu solution |
| Precision (RSD) | <0.45% |
| Detection Limit | Sub-ppb for most elements with graphite furnace |
| Software Control | Handheld PC-based interface |
| Lamp Positions | 2 fixed hollow cathode lamp slots |
| Upgrade Path | Field-upgradable to graphite furnace and hydride generation systems |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Model | 7030A |
| Monochromator | Concave Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Spectral Bandwidth | 0.2 nm (measured spectral line half-width ≤ 0.2 nm ± 0.02 nm) |
| Sensitivity | Cu, 2.0 mg/L → Abs ≥ 0.200 Abs |
| Repeatability (RSD) | ≤1% |
| Detection Limit | Cu ≤ 0.010 mg/L |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | System5000 |
| Detection Limit | Sub-ppb for ~50 elements |
| Temperature Range | Up to 3000 °C |
| Sample Volume | 1–100 µL (1 µL increment) |
| Autosampler Capacity | 40 samples + 10 standards |
| Vial Sizes | 2 mL (samples/standards), 5 mL (auto-dilution), 10 mL (reagents/blanks) |
| Graphite Tube | Platform-equipped high-performance tube |
| Gas Control | Programmable purge gas selection (Ar, N₂, or mixed) |
| Chemical Modifier Injection | Dual-channel, software-triggered |
| Syringe Material | Fully PTFE capillary |
| Wash Reservoir | 1 L |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra4040 |
| Optical Design | True Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Automation | Fully Automatic |
| Slit Width Range | 0.1–2.0 nm |
| Stray Light | <0.0005% T at 220 nm |
| Photometric Linearity | ±1.2% up to 5 Abs |
| Monochromator Configuration | Dual Littrow, Czerny-Turner |
| Dynamic Range | >6 Abs (measured) |
| Compliance | ASTM E275, ISO 6358, USP <857>, EP 2.2.25, JP 2.03 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | AS-500 |
| Pricing | Available Upon Request |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-MS3110 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC/MS Configuration | Conventional Benchtop GC-MS |
| Mass Range | 1.5–800 Da |
| Resolution | 2 M (10% valley definition) |
| Sensitivity | 30:1 (S/N for 1 pg octafluoronaphthalene, m/z 272, in full-scan mode) |
| Scan Speed | 6000 u/sec |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SDS720 |
| Pricing | Available Upon Request |
| Sample Capacity | 360 positions (standard), expandable to 720 |
| Vial Compatibility | 240 × 14 mL vials + 10 × 50 mL standard vials |
| Fluid Path Materials | PTFE and PEEK only (metal-free) |
| Cleaning System | Peristaltic-pump-driven continuous-flow probe wash station |
| Overflow Protection | Fixed overflow tray |
| Instrument Compatibility | GBC XplorAA, SensAA, SavantAA AAS |
| Control Interface | PC-based software with programmable wash time, delay time, replicate injection count, recalibration interval, restandardization cycle, measurement duration, and sequence logic |
| Sampling Mode | Fully random-access sampling |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | FS3000 |
| Sample Capacity | 10 calibration standards + 60 sample positions |
| Dedicated Vial Locations | rinse solution, blank solution, and recalibration standard |
| Programmable Parameters | measurement interval, pre-measurement delay, wash cycle duration, recalibration frequency, restandardization frequency, number of calibration standards, replicate count per sample, first/last sample position indexing |
| Distribution Status | Authorized International Distributor (Imported Equipment) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | PS720 |
| Type | Automated Dilution Module for Atomic Absorption Spectroscopy |
| Integration | Designed exclusively for use with GBC SDS720 Autosampler and SavantAA Software |
| Control Interface | Fully integrated via SavantAA v5.0+ |
| Compatibility | Flame AAS (FAAS) and Hydride Generation AAS (HGAAS) |
| Automation Scope | Full dilution, standard addition, internal standard recovery, and up to two chemical modifier additions |
| Mechanical Integration | Synchronized with GBC’s motorized burner head rotation system for extended linear dynamic range |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | AA-7095 Atomic Absorption Spectrometer |
| Pricing | Upon Request |
| Light Source Configuration | 8-lamp turret with simultaneous preheating |
| Spectral Bandwidth Options | 0.1, 0.2, 0.4, 0.7, 1.0, and 2.0 nm (6-step automated slit selection) |
| Background Correction | Dual-mode — longitudinal AC Zeeman effect + D₂ lamp |
| Auto-Optimization Functions | Automated zeroing, wavelength scanning, hollow cathode lamp positioning, mirror alignment, and energy balancing |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Coal Mining Industry |
| Detection Channels | 3 Independent Parallel Channels (A/B/C) |
| Channel A | O₂, N₂, CH₄, CO₂ |
| Channel B | C₂H₄, C₂H₆, C₂H₂, C₃H₈, H₂S |
| Channel C | H₂, CO |
| LOD | O₂/N₂/CH₄/CO₂ ≤ 0.1% (v/v) |
| Quantitative Repeatability | ≤ 3% RSD |
| Sample Introduction | Motorized 10-Port Automatic Valve with Precise Retention Time Control |
| Control Interface | Industrial Touchscreen LCD with One-Touch Power-On Sequence |
| Data Output | Real-Time Peak Area and Concentration Calculation per Component |
| Brand | East & West Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-4100 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | (Ambient + 5) °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 400 °C → 50 °C (typical) |
| Carrier Gas Flow Control Range | 1–500 mL/min (EPC) |
| Carrier Gas Pressure Control Range | 0–145 psi (EPC) |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–145 psi (EPC) |
| Injector Total Flow Setting Range | 1–500 mL/min (EPC) |